Cargando…

A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices

BACKGROUND: We developed a new 6-Fr guiding catheter (Slim Guide(®)) that features a large lumen (0.072 inch) for performing advanced techniques as are required in patients with wide-necked aneurysms whose treatment with a single microcatheter is difficult. METHODS: The Slim Guide was used to addres...

Descripción completa

Detalles Bibliográficos
Autores principales: Kai, Yutaka, Ohmori, Yuki, Watanabe, Masaki, Kaku, Yasuyuki, Morioka, Motohiro, Hirano, Teruyuki, Yano, Shigetoshi, Kawano, Takayuki, Hamada, Jun-ichiro, Kuratsu, Jun-ichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3385052/
https://www.ncbi.nlm.nih.gov/pubmed/22754724
http://dx.doi.org/10.4103/2152-7806.97003
_version_ 1782236787476791296
author Kai, Yutaka
Ohmori, Yuki
Watanabe, Masaki
Kaku, Yasuyuki
Morioka, Motohiro
Hirano, Teruyuki
Yano, Shigetoshi
Kawano, Takayuki
Hamada, Jun-ichiro
Kuratsu, Jun-ichi
author_facet Kai, Yutaka
Ohmori, Yuki
Watanabe, Masaki
Kaku, Yasuyuki
Morioka, Motohiro
Hirano, Teruyuki
Yano, Shigetoshi
Kawano, Takayuki
Hamada, Jun-ichiro
Kuratsu, Jun-ichi
author_sort Kai, Yutaka
collection PubMed
description BACKGROUND: We developed a new 6-Fr guiding catheter (Slim Guide(®)) that features a large lumen (0.072 inch) for performing advanced techniques as are required in patients with wide-necked aneurysms whose treatment with a single microcatheter is difficult. METHODS: The Slim Guide was used to address 30 saccular and 20 dissecting aneurysms. All 50 patients presented with subarachnoid hemorrhage. To perform the advanced techniques we used SL-10(®) or Excel 14(®) and Hyperform(®) balloon microcatheters. RESULTS: Of the 30 patients with saccular aneurysms, 20 were treated with the double microcatheter- and the other 10 with the balloon assist technique. All 20 patients with dissecting aneurysms were treated with the double microcatheter technique. We encountered slight interference during the treatment of one saccular aneurysm with the balloon assist technique using the Slim Guide guiding catheter; another patient with a saccular aneurysm treated with the balloon assist technique suffered a minor transient ischemic complication. CONCLUSIONS: With the Slim Guide, the risks inherent in the application of advanced techniques may be decreased. Its use facilitates the coil embolization of aneurysms that pose treatment challenges.
format Online
Article
Text
id pubmed-3385052
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-33850522012-07-02 A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices Kai, Yutaka Ohmori, Yuki Watanabe, Masaki Kaku, Yasuyuki Morioka, Motohiro Hirano, Teruyuki Yano, Shigetoshi Kawano, Takayuki Hamada, Jun-ichiro Kuratsu, Jun-ichi Surg Neurol Int Original Article BACKGROUND: We developed a new 6-Fr guiding catheter (Slim Guide(®)) that features a large lumen (0.072 inch) for performing advanced techniques as are required in patients with wide-necked aneurysms whose treatment with a single microcatheter is difficult. METHODS: The Slim Guide was used to address 30 saccular and 20 dissecting aneurysms. All 50 patients presented with subarachnoid hemorrhage. To perform the advanced techniques we used SL-10(®) or Excel 14(®) and Hyperform(®) balloon microcatheters. RESULTS: Of the 30 patients with saccular aneurysms, 20 were treated with the double microcatheter- and the other 10 with the balloon assist technique. All 20 patients with dissecting aneurysms were treated with the double microcatheter technique. We encountered slight interference during the treatment of one saccular aneurysm with the balloon assist technique using the Slim Guide guiding catheter; another patient with a saccular aneurysm treated with the balloon assist technique suffered a minor transient ischemic complication. CONCLUSIONS: With the Slim Guide, the risks inherent in the application of advanced techniques may be decreased. Its use facilitates the coil embolization of aneurysms that pose treatment challenges. Medknow Publications & Media Pvt Ltd 2012-06-09 /pmc/articles/PMC3385052/ /pubmed/22754724 http://dx.doi.org/10.4103/2152-7806.97003 Text en Copyright: © 2012 Kai Y. http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Original Article
Kai, Yutaka
Ohmori, Yuki
Watanabe, Masaki
Kaku, Yasuyuki
Morioka, Motohiro
Hirano, Teruyuki
Yano, Shigetoshi
Kawano, Takayuki
Hamada, Jun-ichiro
Kuratsu, Jun-ichi
A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices
title A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices
title_full A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices
title_fullStr A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices
title_full_unstemmed A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices
title_short A 6-Fr guiding catheter (Slim Guide(®)) for use with multiple microdevices
title_sort 6-fr guiding catheter (slim guide(®)) for use with multiple microdevices
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3385052/
https://www.ncbi.nlm.nih.gov/pubmed/22754724
http://dx.doi.org/10.4103/2152-7806.97003
work_keys_str_mv AT kaiyutaka a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT ohmoriyuki a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT watanabemasaki a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kakuyasuyuki a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT moriokamotohiro a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT hiranoteruyuki a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT yanoshigetoshi a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kawanotakayuki a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT hamadajunichiro a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kuratsujunichi a6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kaiyutaka 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT ohmoriyuki 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT watanabemasaki 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kakuyasuyuki 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT moriokamotohiro 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT hiranoteruyuki 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT yanoshigetoshi 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kawanotakayuki 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT hamadajunichiro 6frguidingcatheterslimguideforusewithmultiplemicrodevices
AT kuratsujunichi 6frguidingcatheterslimguideforusewithmultiplemicrodevices