Cargando…

Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea

OBJECTIVES: To investigate the usefulness of measuring upper airway collapsibility with a negative expiratory pressure application as a screening test for severe obstructive sleep apnea (OSA). INTRODUCTION: OSA is a risk factor for cardiovascular disease, and it may have serious consequences. Its re...

Descripción completa

Detalles Bibliográficos
Autores principales: Romano, Salvatore, Salvaggio, Adriana, Hirata, Raquel Pastrello, Bue, Anna Lo, Picciolo, Stefano, de Oliveira, Luis Vicente Franco, Insalaco, Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3386647/
https://www.ncbi.nlm.nih.gov/pubmed/21655748
http://dx.doi.org/10.1590/S1807-59322011000400008
_version_ 1782236997740396544
author Romano, Salvatore
Salvaggio, Adriana
Hirata, Raquel Pastrello
Bue, Anna Lo
Picciolo, Stefano
de Oliveira, Luis Vicente Franco
Insalaco, Giuseppe
author_facet Romano, Salvatore
Salvaggio, Adriana
Hirata, Raquel Pastrello
Bue, Anna Lo
Picciolo, Stefano
de Oliveira, Luis Vicente Franco
Insalaco, Giuseppe
author_sort Romano, Salvatore
collection PubMed
description OBJECTIVES: To investigate the usefulness of measuring upper airway collapsibility with a negative expiratory pressure application as a screening test for severe obstructive sleep apnea (OSA). INTRODUCTION: OSA is a risk factor for cardiovascular disease, and it may have serious consequences. Its recognition may have important implications during the perioperative period. Increased upper airway collapsibility is one of the main determinants of OSA, and its evaluation could be useful for identifying this condition. METHODS: Severe OSA and normal subjects (24 in each group) were matched by body mass index and referred to our sleep laboratory. The subjects were enrolled in an overnight sleep study, and a diurnal negative expiratory pressure test was performed. Flow drop (ΔV̇) and expiratory volume were measured in the first 0.2 s (V(0.2)) of the negative expiratory pressure test. RESULTS: ΔV̇ and V(0.2) (%) values were statistically different between normal and OSA subjects. OSA patients showed a greater decrease in flow than normal subjects. In addition, severely OSA patients exhaled during the first 0.2 s of the negative expiratory pressure application was an average of only 11.2% of the inspired volume compared to 34.2% for the normal subjects. Analysis of the receiver operating characteristics showed that V(0.2) (%) and ΔV̇ could accurately identify severe OSA in subjects with sensitivities of 95.8% and 91.7%, respectively, and specificities of 95.8% and 91.7%, respectively. CONCLUSIONS: V(0.2) (%) and ΔV̇ are highly accurate parameters for detecting severe OSA. The pharyngeal collapsibility measurement, which uses negative expiratory pressure during wakefulness, is predictive of collapsibility during sleep.
format Online
Article
Text
id pubmed-3386647
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-33866472012-07-03 Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea Romano, Salvatore Salvaggio, Adriana Hirata, Raquel Pastrello Bue, Anna Lo Picciolo, Stefano de Oliveira, Luis Vicente Franco Insalaco, Giuseppe Clinics (Sao Paulo) Clinical Science OBJECTIVES: To investigate the usefulness of measuring upper airway collapsibility with a negative expiratory pressure application as a screening test for severe obstructive sleep apnea (OSA). INTRODUCTION: OSA is a risk factor for cardiovascular disease, and it may have serious consequences. Its recognition may have important implications during the perioperative period. Increased upper airway collapsibility is one of the main determinants of OSA, and its evaluation could be useful for identifying this condition. METHODS: Severe OSA and normal subjects (24 in each group) were matched by body mass index and referred to our sleep laboratory. The subjects were enrolled in an overnight sleep study, and a diurnal negative expiratory pressure test was performed. Flow drop (ΔV̇) and expiratory volume were measured in the first 0.2 s (V(0.2)) of the negative expiratory pressure test. RESULTS: ΔV̇ and V(0.2) (%) values were statistically different between normal and OSA subjects. OSA patients showed a greater decrease in flow than normal subjects. In addition, severely OSA patients exhaled during the first 0.2 s of the negative expiratory pressure application was an average of only 11.2% of the inspired volume compared to 34.2% for the normal subjects. Analysis of the receiver operating characteristics showed that V(0.2) (%) and ΔV̇ could accurately identify severe OSA in subjects with sensitivities of 95.8% and 91.7%, respectively, and specificities of 95.8% and 91.7%, respectively. CONCLUSIONS: V(0.2) (%) and ΔV̇ are highly accurate parameters for detecting severe OSA. The pharyngeal collapsibility measurement, which uses negative expiratory pressure during wakefulness, is predictive of collapsibility during sleep. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2011-04 /pmc/articles/PMC3386647/ /pubmed/21655748 http://dx.doi.org/10.1590/S1807-59322011000400008 Text en Copyright © 2011 Hospital das Clínicas da FMUSP http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Science
Romano, Salvatore
Salvaggio, Adriana
Hirata, Raquel Pastrello
Bue, Anna Lo
Picciolo, Stefano
de Oliveira, Luis Vicente Franco
Insalaco, Giuseppe
Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
title Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
title_full Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
title_fullStr Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
title_full_unstemmed Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
title_short Upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
title_sort upper airway collapsibility evaluated by a negative expiratory pressure test in severe obstructive sleep apnea
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3386647/
https://www.ncbi.nlm.nih.gov/pubmed/21655748
http://dx.doi.org/10.1590/S1807-59322011000400008
work_keys_str_mv AT romanosalvatore upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea
AT salvaggioadriana upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea
AT hirataraquelpastrello upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea
AT bueannalo upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea
AT picciolostefano upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea
AT deoliveiraluisvicentefranco upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea
AT insalacogiuseppe upperairwaycollapsibilityevaluatedbyanegativeexpiratorypressuretestinsevereobstructivesleepapnea