Cargando…

Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics

Microparticles, also known as microvesicles, found in blood plasma, urine, and most other body fluids, may serve as valuable biomarkers of diseases such as cardiovascular diseases, systemic inflammatory disease, thrombosis, and cancer. Unfortunately, the detection and quantification of microparticle...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashcroft, B. A., de Sonneville, J., Yuana, Y., Osanto, S., Bertina, R., Kuil, M. E., Oosterkamp, T. H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3388260/
https://www.ncbi.nlm.nih.gov/pubmed/22391880
http://dx.doi.org/10.1007/s10544-012-9642-y
_version_ 1782237159461224448
author Ashcroft, B. A.
de Sonneville, J.
Yuana, Y.
Osanto, S.
Bertina, R.
Kuil, M. E.
Oosterkamp, T. H.
author_facet Ashcroft, B. A.
de Sonneville, J.
Yuana, Y.
Osanto, S.
Bertina, R.
Kuil, M. E.
Oosterkamp, T. H.
author_sort Ashcroft, B. A.
collection PubMed
description Microparticles, also known as microvesicles, found in blood plasma, urine, and most other body fluids, may serve as valuable biomarkers of diseases such as cardiovascular diseases, systemic inflammatory disease, thrombosis, and cancer. Unfortunately, the detection and quantification of microparticles are hampered by the microscopic size of these particles and their relatively low abundance in blood plasma. The use of a combination of microfluidics and atomic force microscopy to detect microparticles in blood plasma circumvents both problems. In this study, capture of a specific subset of microparticles directly from blood plasma on antibody-coated mica surface is demonstrated. The described method excludes isolation and washing steps to prepare microparticles, improves the detection sensitivity, and yields the size distribution of the captured particles. The majority of the captured particles have a size ranging from 30 to 90 nm, which is in good agreement with prior results obtained with microparticles immediately isolated from fresh plasma. Furthermore, the qualitative shape of the size distribution of microparticles is shown not to be affected by high-speed centrifugation or the use of the microfluidic circuit, demonstrating the relative stable nature of microparticles ex vivo. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10544-012-9642-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-3388260
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-33882602012-07-11 Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics Ashcroft, B. A. de Sonneville, J. Yuana, Y. Osanto, S. Bertina, R. Kuil, M. E. Oosterkamp, T. H. Biomed Microdevices Article Microparticles, also known as microvesicles, found in blood plasma, urine, and most other body fluids, may serve as valuable biomarkers of diseases such as cardiovascular diseases, systemic inflammatory disease, thrombosis, and cancer. Unfortunately, the detection and quantification of microparticles are hampered by the microscopic size of these particles and their relatively low abundance in blood plasma. The use of a combination of microfluidics and atomic force microscopy to detect microparticles in blood plasma circumvents both problems. In this study, capture of a specific subset of microparticles directly from blood plasma on antibody-coated mica surface is demonstrated. The described method excludes isolation and washing steps to prepare microparticles, improves the detection sensitivity, and yields the size distribution of the captured particles. The majority of the captured particles have a size ranging from 30 to 90 nm, which is in good agreement with prior results obtained with microparticles immediately isolated from fresh plasma. Furthermore, the qualitative shape of the size distribution of microparticles is shown not to be affected by high-speed centrifugation or the use of the microfluidic circuit, demonstrating the relative stable nature of microparticles ex vivo. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s10544-012-9642-y) contains supplementary material, which is available to authorized users. Springer US 2012-03-06 2012 /pmc/articles/PMC3388260/ /pubmed/22391880 http://dx.doi.org/10.1007/s10544-012-9642-y Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Article
Ashcroft, B. A.
de Sonneville, J.
Yuana, Y.
Osanto, S.
Bertina, R.
Kuil, M. E.
Oosterkamp, T. H.
Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
title Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
title_full Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
title_fullStr Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
title_full_unstemmed Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
title_short Determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
title_sort determination of the size distribution of blood microparticles directly in plasma using atomic force microscopy and microfluidics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3388260/
https://www.ncbi.nlm.nih.gov/pubmed/22391880
http://dx.doi.org/10.1007/s10544-012-9642-y
work_keys_str_mv AT ashcroftba determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics
AT desonnevillej determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics
AT yuanay determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics
AT osantos determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics
AT bertinar determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics
AT kuilme determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics
AT oosterkampth determinationofthesizedistributionofbloodmicroparticlesdirectlyinplasmausingatomicforcemicroscopyandmicrofluidics