Cargando…

High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment

Introduction. Artifactual variations in the ST segment may lead to confusion with acute coronary syndromes. Objective. To evaluate how the technical characteristics of the recording mode may distort the ST segment. Material and Method. We made a series of electrocardiograms using different filter co...

Descripción completa

Detalles Bibliográficos
Autores principales: Buendía-Fuentes, F., Arnau-Vives, M. A., Arnau-Vives, A., Jiménez-Jiménez, Y., Rueda-Soriano, J., Zorio-Grima, E., Osa-Sáez, A., Martínez-Dolz, L. V., Almenar-Bonet, L., Palencia-Pérez, M. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scholarly Research Network 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3388307/
https://www.ncbi.nlm.nih.gov/pubmed/22778996
http://dx.doi.org/10.5402/2012/706217
_version_ 1782237167315058688
author Buendía-Fuentes, F.
Arnau-Vives, M. A.
Arnau-Vives, A.
Jiménez-Jiménez, Y.
Rueda-Soriano, J.
Zorio-Grima, E.
Osa-Sáez, A.
Martínez-Dolz, L. V.
Almenar-Bonet, L.
Palencia-Pérez, M. A.
author_facet Buendía-Fuentes, F.
Arnau-Vives, M. A.
Arnau-Vives, A.
Jiménez-Jiménez, Y.
Rueda-Soriano, J.
Zorio-Grima, E.
Osa-Sáez, A.
Martínez-Dolz, L. V.
Almenar-Bonet, L.
Palencia-Pérez, M. A.
author_sort Buendía-Fuentes, F.
collection PubMed
description Introduction. Artifactual variations in the ST segment may lead to confusion with acute coronary syndromes. Objective. To evaluate how the technical characteristics of the recording mode may distort the ST segment. Material and Method. We made a series of electrocardiograms using different filter configurations in 45 asymptomatic patients. A spectral analysis of the electrocardiograms was made by discrete Fourier transforms, and an accurate recomposition of the ECG signal was obtained from the addition of successive harmonics. Digital high-pass filters of 0.05 and 0.5 Hz were used, and the resulting shapes were compared with the originals. Results. In 42 patients (93%) clinically significant alterations in ST segment level were detected. These changes were only seen in “real time mode” with high-pass filter of 0.5 Hz. Conclusions. Interpretation of the ST segment in “real time mode” should only be carried out using high-pass filters of 0.05 Hz.
format Online
Article
Text
id pubmed-3388307
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher International Scholarly Research Network
record_format MEDLINE/PubMed
spelling pubmed-33883072012-07-09 High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment Buendía-Fuentes, F. Arnau-Vives, M. A. Arnau-Vives, A. Jiménez-Jiménez, Y. Rueda-Soriano, J. Zorio-Grima, E. Osa-Sáez, A. Martínez-Dolz, L. V. Almenar-Bonet, L. Palencia-Pérez, M. A. ISRN Cardiol Research Article Introduction. Artifactual variations in the ST segment may lead to confusion with acute coronary syndromes. Objective. To evaluate how the technical characteristics of the recording mode may distort the ST segment. Material and Method. We made a series of electrocardiograms using different filter configurations in 45 asymptomatic patients. A spectral analysis of the electrocardiograms was made by discrete Fourier transforms, and an accurate recomposition of the ECG signal was obtained from the addition of successive harmonics. Digital high-pass filters of 0.05 and 0.5 Hz were used, and the resulting shapes were compared with the originals. Results. In 42 patients (93%) clinically significant alterations in ST segment level were detected. These changes were only seen in “real time mode” with high-pass filter of 0.5 Hz. Conclusions. Interpretation of the ST segment in “real time mode” should only be carried out using high-pass filters of 0.05 Hz. International Scholarly Research Network 2012-06-21 /pmc/articles/PMC3388307/ /pubmed/22778996 http://dx.doi.org/10.5402/2012/706217 Text en Copyright © 2012 F. Buendía-Fuentes et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Buendía-Fuentes, F.
Arnau-Vives, M. A.
Arnau-Vives, A.
Jiménez-Jiménez, Y.
Rueda-Soriano, J.
Zorio-Grima, E.
Osa-Sáez, A.
Martínez-Dolz, L. V.
Almenar-Bonet, L.
Palencia-Pérez, M. A.
High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment
title High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment
title_full High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment
title_fullStr High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment
title_full_unstemmed High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment
title_short High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST Segment
title_sort high-bandpass filters in electrocardiography: source of error in the interpretation of the st segment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3388307/
https://www.ncbi.nlm.nih.gov/pubmed/22778996
http://dx.doi.org/10.5402/2012/706217
work_keys_str_mv AT buendiafuentesf highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT arnauvivesma highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT arnauvivesa highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT jimenezjimenezy highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT ruedasorianoj highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT zoriogrimae highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT osasaeza highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT martinezdolzlv highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT almenarbonetl highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment
AT palenciaperezma highbandpassfiltersinelectrocardiographysourceoferrorintheinterpretationofthestsegment