Cargando…
Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System
The blood vessel morphology is known to correlate with several diseases, such as cancer, and is important for describing several tissue physiological processes, like angiogenesis. Therefore, a quantitative method for characterizing the angiography obtained from medical images would have several clin...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3389716/ https://www.ncbi.nlm.nih.gov/pubmed/22792084 http://dx.doi.org/10.1155/2012/509783 |
_version_ | 1782237346301739008 |
---|---|
author | Reif, Roberto Qin, Jia An, Lin Zhi, Zhongwei Dziennis, Suzan Wang, Ruikang |
author_facet | Reif, Roberto Qin, Jia An, Lin Zhi, Zhongwei Dziennis, Suzan Wang, Ruikang |
author_sort | Reif, Roberto |
collection | PubMed |
description | The blood vessel morphology is known to correlate with several diseases, such as cancer, and is important for describing several tissue physiological processes, like angiogenesis. Therefore, a quantitative method for characterizing the angiography obtained from medical images would have several clinical applications. Optical microangiography (OMAG) is a method for obtaining three-dimensional images of blood vessels within a volume of tissue. In this study we propose to quantify OMAG images obtained with a spectral domain optical coherence tomography system. A technique for determining three measureable parameters (the fractal dimension, the vessel length fraction, and the vessel area density) is proposed and validated. Finally, the repeatability for acquiring OMAG images is determined, and a new method for analyzing small areas from these images is proposed. |
format | Online Article Text |
id | pubmed-3389716 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-33897162012-07-12 Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System Reif, Roberto Qin, Jia An, Lin Zhi, Zhongwei Dziennis, Suzan Wang, Ruikang Int J Biomed Imaging Research Article The blood vessel morphology is known to correlate with several diseases, such as cancer, and is important for describing several tissue physiological processes, like angiogenesis. Therefore, a quantitative method for characterizing the angiography obtained from medical images would have several clinical applications. Optical microangiography (OMAG) is a method for obtaining three-dimensional images of blood vessels within a volume of tissue. In this study we propose to quantify OMAG images obtained with a spectral domain optical coherence tomography system. A technique for determining three measureable parameters (the fractal dimension, the vessel length fraction, and the vessel area density) is proposed and validated. Finally, the repeatability for acquiring OMAG images is determined, and a new method for analyzing small areas from these images is proposed. Hindawi Publishing Corporation 2012 2012-06-26 /pmc/articles/PMC3389716/ /pubmed/22792084 http://dx.doi.org/10.1155/2012/509783 Text en Copyright © 2012 Roberto Reif et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Reif, Roberto Qin, Jia An, Lin Zhi, Zhongwei Dziennis, Suzan Wang, Ruikang Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System |
title | Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System |
title_full | Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System |
title_fullStr | Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System |
title_full_unstemmed | Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System |
title_short | Quantifying Optical Microangiography Images Obtained from a Spectral Domain Optical Coherence Tomography System |
title_sort | quantifying optical microangiography images obtained from a spectral domain optical coherence tomography system |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3389716/ https://www.ncbi.nlm.nih.gov/pubmed/22792084 http://dx.doi.org/10.1155/2012/509783 |
work_keys_str_mv | AT reifroberto quantifyingopticalmicroangiographyimagesobtainedfromaspectraldomainopticalcoherencetomographysystem AT qinjia quantifyingopticalmicroangiographyimagesobtainedfromaspectraldomainopticalcoherencetomographysystem AT anlin quantifyingopticalmicroangiographyimagesobtainedfromaspectraldomainopticalcoherencetomographysystem AT zhizhongwei quantifyingopticalmicroangiographyimagesobtainedfromaspectraldomainopticalcoherencetomographysystem AT dziennissuzan quantifyingopticalmicroangiographyimagesobtainedfromaspectraldomainopticalcoherencetomographysystem AT wangruikang quantifyingopticalmicroangiographyimagesobtainedfromaspectraldomainopticalcoherencetomographysystem |