Cargando…

Effects of zero reference position on bladder pressure measurements: an observational study

BACKGROUND: Although the World Society for Abdominal Compartment Syndrome in its guidelines recommends midaxillary line (MAL) as zero reference level in intra-abdominal pressure (IAP) measurements in aiming at standardizing the technique, evidence supporting this suggestion is scarce. The aim of thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Soler Morej&#243n, Caridad De Dios, Lombardo, Tomás Ariel, Tamargo Barbeito, Teddy Osmin, Sandra, Barquín García
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3390299/
https://www.ncbi.nlm.nih.gov/pubmed/22873414
http://dx.doi.org/10.1186/2110-5820-2-S1-S13
_version_ 1782237423285043200
author Soler Morej&#243n, Caridad De Dios
Lombardo, Tomás Ariel
Tamargo Barbeito, Teddy Osmin
Sandra, Barquín García
author_facet Soler Morej&#243n, Caridad De Dios
Lombardo, Tomás Ariel
Tamargo Barbeito, Teddy Osmin
Sandra, Barquín García
author_sort Soler Morej&#243n, Caridad De Dios
collection PubMed
description BACKGROUND: Although the World Society for Abdominal Compartment Syndrome in its guidelines recommends midaxillary line (MAL) as zero reference level in intra-abdominal pressure (IAP) measurements in aiming at standardizing the technique, evidence supporting this suggestion is scarce. The aim of this study is to study if the zero reference position influences bladder pressure measurements as estimate for IAP. METHODS: The IAP of 100 surgical patients was measured during the first 24 h of admission to the surgical intensive care unit of General Calixto Garcia Hospital in Havana (Cuba) following laparotomy. The period was January 2009 to January 2010. The IAP was measured twice with a six-hour interval using the transurethral technique with a priming volume of 25 ml. IAP was first measured with the zero reference level placed at MAL (IAP(MAL)), followed by a second measurement at the level of the symphysis pubis (SP) after 3 minutes (IAP(SP)). Correlations were made between IAP and body mass index (BMI), type of surgery, gender, and age. RESULTS: Mean IAP(MAL )was 8.5 ± 2.8 mmHg vs. IAP(SP )6.5 ± 2.8 mmHg (p < 0.0001). The bias between measurements was 2.0 ± 1.5, 95% confidence interval of 1.4 to 3.0, upper limit of 4.9, lower limit of -0.9, and a percentage error of 35.1%. IAP(MAL )was consistently higher than IAP(SP )regardless of the type of surgery. The BMI correlated with IAP values regardless of the zero reference level (R(2 )= 0.4 and 0.3 with IAP(MAL )and IAP(SP )respectively, p < 0.0001). CONCLUSIONS: The zero reference level has an important impact on IAP measurement in surgical patients after laparotomy and can potentially lead to over or underestimation. Further anthropometric studies are needed with regard to the relative MAL and SP zero reference position in relation to the theoretical ideal reference level at midpoint of the abdomen. Until better evidence is available, MAL remains the recommended zero reference position due to its best anatomical localization at iliac crest.
format Online
Article
Text
id pubmed-3390299
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Springer
record_format MEDLINE/PubMed
spelling pubmed-33902992012-07-06 Effects of zero reference position on bladder pressure measurements: an observational study Soler Morej&#243n, Caridad De Dios Lombardo, Tomás Ariel Tamargo Barbeito, Teddy Osmin Sandra, Barquín García Ann Intensive Care Research BACKGROUND: Although the World Society for Abdominal Compartment Syndrome in its guidelines recommends midaxillary line (MAL) as zero reference level in intra-abdominal pressure (IAP) measurements in aiming at standardizing the technique, evidence supporting this suggestion is scarce. The aim of this study is to study if the zero reference position influences bladder pressure measurements as estimate for IAP. METHODS: The IAP of 100 surgical patients was measured during the first 24 h of admission to the surgical intensive care unit of General Calixto Garcia Hospital in Havana (Cuba) following laparotomy. The period was January 2009 to January 2010. The IAP was measured twice with a six-hour interval using the transurethral technique with a priming volume of 25 ml. IAP was first measured with the zero reference level placed at MAL (IAP(MAL)), followed by a second measurement at the level of the symphysis pubis (SP) after 3 minutes (IAP(SP)). Correlations were made between IAP and body mass index (BMI), type of surgery, gender, and age. RESULTS: Mean IAP(MAL )was 8.5 ± 2.8 mmHg vs. IAP(SP )6.5 ± 2.8 mmHg (p < 0.0001). The bias between measurements was 2.0 ± 1.5, 95% confidence interval of 1.4 to 3.0, upper limit of 4.9, lower limit of -0.9, and a percentage error of 35.1%. IAP(MAL )was consistently higher than IAP(SP )regardless of the type of surgery. The BMI correlated with IAP values regardless of the zero reference level (R(2 )= 0.4 and 0.3 with IAP(MAL )and IAP(SP )respectively, p < 0.0001). CONCLUSIONS: The zero reference level has an important impact on IAP measurement in surgical patients after laparotomy and can potentially lead to over or underestimation. Further anthropometric studies are needed with regard to the relative MAL and SP zero reference position in relation to the theoretical ideal reference level at midpoint of the abdomen. Until better evidence is available, MAL remains the recommended zero reference position due to its best anatomical localization at iliac crest. Springer 2012-07-05 /pmc/articles/PMC3390299/ /pubmed/22873414 http://dx.doi.org/10.1186/2110-5820-2-S1-S13 Text en Copyright ©2012 Soler Morej&#243n et al.; licensee Springer http://creativecommons.org/licenses/by/2.0 This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Soler Morej&#243n, Caridad De Dios
Lombardo, Tomás Ariel
Tamargo Barbeito, Teddy Osmin
Sandra, Barquín García
Effects of zero reference position on bladder pressure measurements: an observational study
title Effects of zero reference position on bladder pressure measurements: an observational study
title_full Effects of zero reference position on bladder pressure measurements: an observational study
title_fullStr Effects of zero reference position on bladder pressure measurements: an observational study
title_full_unstemmed Effects of zero reference position on bladder pressure measurements: an observational study
title_short Effects of zero reference position on bladder pressure measurements: an observational study
title_sort effects of zero reference position on bladder pressure measurements: an observational study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3390299/
https://www.ncbi.nlm.nih.gov/pubmed/22873414
http://dx.doi.org/10.1186/2110-5820-2-S1-S13
work_keys_str_mv AT solermorej243ncaridaddedios effectsofzeroreferencepositiononbladderpressuremeasurementsanobservationalstudy
AT lombardotomasariel effectsofzeroreferencepositiononbladderpressuremeasurementsanobservationalstudy
AT tamargobarbeitoteddyosmin effectsofzeroreferencepositiononbladderpressuremeasurementsanobservationalstudy
AT sandrabarquingarcia effectsofzeroreferencepositiononbladderpressuremeasurementsanobservationalstudy