Cargando…
Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation
OBJECTIVES: We assessed the safety, efficacy, and tolerability of a new preparation of Gatorade and polyethylene glycol (PEG) for colonoscopy with or without bisacodyl compared with NuLYTELY. METHODS: We performed an investigator-blinded, placebo-controlled, randomized trial of 64 oz of Gatorade and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3391000/ https://www.ncbi.nlm.nih.gov/pubmed/23238266 http://dx.doi.org/10.1038/ctg.2012.11 |
_version_ | 1782237480106328064 |
---|---|
author | Gerard, David P Holden, John L Foster, Diane B Raiser, Manfred W |
author_facet | Gerard, David P Holden, John L Foster, Diane B Raiser, Manfred W |
author_sort | Gerard, David P |
collection | PubMed |
description | OBJECTIVES: We assessed the safety, efficacy, and tolerability of a new preparation of Gatorade and polyethylene glycol (PEG) for colonoscopy with or without bisacodyl compared with NuLYTELY. METHODS: We performed an investigator-blinded, placebo-controlled, randomized trial of 64 oz of Gatorade and 306 g of PEG (G/PEG) with or without 10 mg of bisacodyl and NuLYTELY. A total of 600 outpatients consumed their preparation the day before a morning colonoscopy. The primary endpoint was colon cleanliness assessed by the Boston Bowel Preparation Scale (BBPS). Tolerability was assessed using a subject questionnaire, and safety was assessed from a basic metabolic profile drawn before the colonoscopy. RESULTS: Adding bisacodyl to G/PEG caused more abdominal bloating/cramps (P<0.01) and did not result in a cleaner colon (P=0.66) compared with G/PEG without bisacodyl. The BBPS scores in both the G/PEG arms and NuLYTELY arm were not significantly different (P=0.19). Compared with subjects in the NuLYTELY arm, subjects in the G/PEG without bisacodyl arm had less nausea (P<0.04), vomiting (P<0.02), abdominal pain (P<0.02), bloating (P<0.005), difficulty drinking the liquid (P<0.0001), and found the overall preparation easier to tolerate (P<0.0001). Subjects in the combined G/PEG arms had a lower serum sodium (P<0.0007), chloride (P<0.007), and BUN (P<0.0001) levels than those in the NuLYTELY arm, but this did not cause any clinical symptoms. CONCLUSIONS: Bisacodyl added to G/PEG for colon lavage caused more side effects and did not result in a cleaner colon. The G/PEG preparations cleansed the colon as well as NuLYTELY, were far better tolerated, and were equally safe. |
format | Online Article Text |
id | pubmed-3391000 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Nature Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-33910002012-07-06 Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation Gerard, David P Holden, John L Foster, Diane B Raiser, Manfred W Clin Transl Gastroenterol Endoscopy OBJECTIVES: We assessed the safety, efficacy, and tolerability of a new preparation of Gatorade and polyethylene glycol (PEG) for colonoscopy with or without bisacodyl compared with NuLYTELY. METHODS: We performed an investigator-blinded, placebo-controlled, randomized trial of 64 oz of Gatorade and 306 g of PEG (G/PEG) with or without 10 mg of bisacodyl and NuLYTELY. A total of 600 outpatients consumed their preparation the day before a morning colonoscopy. The primary endpoint was colon cleanliness assessed by the Boston Bowel Preparation Scale (BBPS). Tolerability was assessed using a subject questionnaire, and safety was assessed from a basic metabolic profile drawn before the colonoscopy. RESULTS: Adding bisacodyl to G/PEG caused more abdominal bloating/cramps (P<0.01) and did not result in a cleaner colon (P=0.66) compared with G/PEG without bisacodyl. The BBPS scores in both the G/PEG arms and NuLYTELY arm were not significantly different (P=0.19). Compared with subjects in the NuLYTELY arm, subjects in the G/PEG without bisacodyl arm had less nausea (P<0.04), vomiting (P<0.02), abdominal pain (P<0.02), bloating (P<0.005), difficulty drinking the liquid (P<0.0001), and found the overall preparation easier to tolerate (P<0.0001). Subjects in the combined G/PEG arms had a lower serum sodium (P<0.0007), chloride (P<0.007), and BUN (P<0.0001) levels than those in the NuLYTELY arm, but this did not cause any clinical symptoms. CONCLUSIONS: Bisacodyl added to G/PEG for colon lavage caused more side effects and did not result in a cleaner colon. The G/PEG preparations cleansed the colon as well as NuLYTELY, were far better tolerated, and were equally safe. Nature Publishing Group 2012-06 2012-06-21 /pmc/articles/PMC3391000/ /pubmed/23238266 http://dx.doi.org/10.1038/ctg.2012.11 Text en Copyright © 2012 American College of Gastroenterology http://creativecommons.org/licenses/by-nc-nd/3.0/ This work is licensed under the Creative Commons Attribution-NonCommercial-No Derivative Works 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/ |
spellingShingle | Endoscopy Gerard, David P Holden, John L Foster, Diane B Raiser, Manfred W Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation |
title | Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation |
title_full | Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation |
title_fullStr | Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation |
title_full_unstemmed | Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation |
title_short | Randomized Trial of Gatorade/Polyethylene Glycol With or Without Bisacodyl and NuLYTELY for Colonoscopy Preparation |
title_sort | randomized trial of gatorade/polyethylene glycol with or without bisacodyl and nulytely for colonoscopy preparation |
topic | Endoscopy |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3391000/ https://www.ncbi.nlm.nih.gov/pubmed/23238266 http://dx.doi.org/10.1038/ctg.2012.11 |
work_keys_str_mv | AT gerarddavidp randomizedtrialofgatoradepolyethyleneglycolwithorwithoutbisacodylandnulytelyforcolonoscopypreparation AT holdenjohnl randomizedtrialofgatoradepolyethyleneglycolwithorwithoutbisacodylandnulytelyforcolonoscopypreparation AT fosterdianeb randomizedtrialofgatoradepolyethyleneglycolwithorwithoutbisacodylandnulytelyforcolonoscopypreparation AT raisermanfredw randomizedtrialofgatoradepolyethyleneglycolwithorwithoutbisacodylandnulytelyforcolonoscopypreparation |