Cargando…
Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis
Objective To determine the diagnostic accuracy of two “spot urine” tests for significant proteinuria or adverse pregnancy outcome in pregnant women with suspected pre-eclampsia. Design Systematic review and meta-analysis. Data sources Searches of electronic databases 1980 to January 2011, reference...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group Ltd.
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3392077/ https://www.ncbi.nlm.nih.gov/pubmed/22777026 http://dx.doi.org/10.1136/bmj.e4342 |
_version_ | 1782237591564713984 |
---|---|
author | Morris, R K Riley, R D Doug, M Deeks, J J Kilby, M D |
author_facet | Morris, R K Riley, R D Doug, M Deeks, J J Kilby, M D |
author_sort | Morris, R K |
collection | PubMed |
description | Objective To determine the diagnostic accuracy of two “spot urine” tests for significant proteinuria or adverse pregnancy outcome in pregnant women with suspected pre-eclampsia. Design Systematic review and meta-analysis. Data sources Searches of electronic databases 1980 to January 2011, reference list checking, hand searching of journals, and contact with experts. Inclusion criteria Diagnostic studies, in pregnant women with hypertension, that compared the urinary spot protein to creatinine ratio or albumin to creatinine ratio with urinary protein excretion over 24 hours or adverse pregnancy outcome. Study characteristics, design, and methodological and reporting quality were objectively assessed. Data extraction Study results relating to diagnostic accuracy were extracted and synthesised using multivariate random effects meta-analysis methods. Results Twenty studies, testing 2978 women (pregnancies), were included. Thirteen studies examining protein to creatinine ratio for the detection of significant proteinuria were included in the multivariate analysis. Threshold values for protein to creatinine ratio ranged between 0.13 and 0.5, with estimates of sensitivity ranging from 0.65 to 0.89 and estimates of specificity from 0.63 to 0.87; the area under the summary receiver operating characteristics curve was 0.69. On average, across all studies, the optimum threshold (that optimises sensitivity and specificity combined) seems to be between 0.30 and 0.35 inclusive. However, no threshold gave a summary estimate above 80% for both sensitivity and specificity, and considerable heterogeneity existed in diagnostic accuracy across studies at most thresholds. No studies looked at protein to creatinine ratio and adverse pregnancy outcome. For albumin to creatinine ratio, meta-analysis was not possible. Results from a single study suggested that the most predictive result, for significant proteinuria, was with the DCA 2000 quantitative analyser (>2 mg/mmol) with a summary sensitivity of 0.94 (95% confidence interval 0.86 to 0.98) and a specificity of 0.94 (0.87 to 0.98). In a single study of adverse pregnancy outcome, results for perinatal death were a sensitivity of 0.82 (0.48 to 0.98) and a specificity of 0.59 (0.51 to 0.67). Conclusion The maternal “spot urine” estimate of protein to creatinine ratio shows promising diagnostic value for significant proteinuria in suspected pre-eclampsia. The existing evidence is not, however, sufficient to determine how protein to creatinine ratio should be used in clinical practice, owing to the heterogeneity in test accuracy and prevalence across studies. Insufficient evidence is available on the use of albumin to creatinine ratio in this area. Insufficient evidence exists for either test to predict adverse pregnancy outcome. |
format | Online Article Text |
id | pubmed-3392077 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BMJ Publishing Group Ltd. |
record_format | MEDLINE/PubMed |
spelling | pubmed-33920772012-07-10 Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis Morris, R K Riley, R D Doug, M Deeks, J J Kilby, M D BMJ Research Objective To determine the diagnostic accuracy of two “spot urine” tests for significant proteinuria or adverse pregnancy outcome in pregnant women with suspected pre-eclampsia. Design Systematic review and meta-analysis. Data sources Searches of electronic databases 1980 to January 2011, reference list checking, hand searching of journals, and contact with experts. Inclusion criteria Diagnostic studies, in pregnant women with hypertension, that compared the urinary spot protein to creatinine ratio or albumin to creatinine ratio with urinary protein excretion over 24 hours or adverse pregnancy outcome. Study characteristics, design, and methodological and reporting quality were objectively assessed. Data extraction Study results relating to diagnostic accuracy were extracted and synthesised using multivariate random effects meta-analysis methods. Results Twenty studies, testing 2978 women (pregnancies), were included. Thirteen studies examining protein to creatinine ratio for the detection of significant proteinuria were included in the multivariate analysis. Threshold values for protein to creatinine ratio ranged between 0.13 and 0.5, with estimates of sensitivity ranging from 0.65 to 0.89 and estimates of specificity from 0.63 to 0.87; the area under the summary receiver operating characteristics curve was 0.69. On average, across all studies, the optimum threshold (that optimises sensitivity and specificity combined) seems to be between 0.30 and 0.35 inclusive. However, no threshold gave a summary estimate above 80% for both sensitivity and specificity, and considerable heterogeneity existed in diagnostic accuracy across studies at most thresholds. No studies looked at protein to creatinine ratio and adverse pregnancy outcome. For albumin to creatinine ratio, meta-analysis was not possible. Results from a single study suggested that the most predictive result, for significant proteinuria, was with the DCA 2000 quantitative analyser (>2 mg/mmol) with a summary sensitivity of 0.94 (95% confidence interval 0.86 to 0.98) and a specificity of 0.94 (0.87 to 0.98). In a single study of adverse pregnancy outcome, results for perinatal death were a sensitivity of 0.82 (0.48 to 0.98) and a specificity of 0.59 (0.51 to 0.67). Conclusion The maternal “spot urine” estimate of protein to creatinine ratio shows promising diagnostic value for significant proteinuria in suspected pre-eclampsia. The existing evidence is not, however, sufficient to determine how protein to creatinine ratio should be used in clinical practice, owing to the heterogeneity in test accuracy and prevalence across studies. Insufficient evidence is available on the use of albumin to creatinine ratio in this area. Insufficient evidence exists for either test to predict adverse pregnancy outcome. BMJ Publishing Group Ltd. 2012-07-09 /pmc/articles/PMC3392077/ /pubmed/22777026 http://dx.doi.org/10.1136/bmj.e4342 Text en © Morris et al 2012 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-commercial License, which permits use, distribution, and reproduction in any medium, provided the original work is properly cited, the use is non commercial and is otherwise in compliance with the license. See: http://creativecommons.org/licenses/by-nc/2.0/ and http://creativecommons.org/licenses/by-nc/2.0/legalcode. |
spellingShingle | Research Morris, R K Riley, R D Doug, M Deeks, J J Kilby, M D Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
title | Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
title_full | Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
title_fullStr | Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
title_full_unstemmed | Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
title_short | Diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
title_sort | diagnostic accuracy of spot urinary protein and albumin to creatinine ratios for detection of significant proteinuria or adverse pregnancy outcome in patients with suspected pre-eclampsia: systematic review and meta-analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3392077/ https://www.ncbi.nlm.nih.gov/pubmed/22777026 http://dx.doi.org/10.1136/bmj.e4342 |
work_keys_str_mv | AT morrisrk diagnosticaccuracyofspoturinaryproteinandalbumintocreatinineratiosfordetectionofsignificantproteinuriaoradversepregnancyoutcomeinpatientswithsuspectedpreeclampsiasystematicreviewandmetaanalysis AT rileyrd diagnosticaccuracyofspoturinaryproteinandalbumintocreatinineratiosfordetectionofsignificantproteinuriaoradversepregnancyoutcomeinpatientswithsuspectedpreeclampsiasystematicreviewandmetaanalysis AT dougm diagnosticaccuracyofspoturinaryproteinandalbumintocreatinineratiosfordetectionofsignificantproteinuriaoradversepregnancyoutcomeinpatientswithsuspectedpreeclampsiasystematicreviewandmetaanalysis AT deeksjj diagnosticaccuracyofspoturinaryproteinandalbumintocreatinineratiosfordetectionofsignificantproteinuriaoradversepregnancyoutcomeinpatientswithsuspectedpreeclampsiasystematicreviewandmetaanalysis AT kilbymd diagnosticaccuracyofspoturinaryproteinandalbumintocreatinineratiosfordetectionofsignificantproteinuriaoradversepregnancyoutcomeinpatientswithsuspectedpreeclampsiasystematicreviewandmetaanalysis |