Cargando…

Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch

Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide...

Descripción completa

Detalles Bibliográficos
Autores principales: Ruggeri, Marco, Uhlhorn, Stephen R., De Freitas, Carolina, Ho, Arthur, Manns, Fabrice, Parel, Jean-Marie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395477/
https://www.ncbi.nlm.nih.gov/pubmed/22808424
http://dx.doi.org/10.1364/BOE.3.001506
_version_ 1782237984548978688
author Ruggeri, Marco
Uhlhorn, Stephen R.
De Freitas, Carolina
Ho, Arthur
Manns, Fabrice
Parel, Jean-Marie
author_facet Ruggeri, Marco
Uhlhorn, Stephen R.
De Freitas, Carolina
Ho, Arthur
Manns, Fabrice
Parel, Jean-Marie
author_sort Ruggeri, Marco
collection PubMed
description Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time.
format Online
Article
Text
id pubmed-3395477
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-33954772012-07-17 Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch Ruggeri, Marco Uhlhorn, Stephen R. De Freitas, Carolina Ho, Arthur Manns, Fabrice Parel, Jean-Marie Biomed Opt Express Ophthalmology Applications Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time. Optical Society of America 2012-06-06 /pmc/articles/PMC3395477/ /pubmed/22808424 http://dx.doi.org/10.1364/BOE.3.001506 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Ophthalmology Applications
Ruggeri, Marco
Uhlhorn, Stephen R.
De Freitas, Carolina
Ho, Arthur
Manns, Fabrice
Parel, Jean-Marie
Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
title Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
title_full Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
title_fullStr Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
title_full_unstemmed Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
title_short Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
title_sort imaging and full-length biometry of the eye during accommodation using spectral domain oct with an optical switch
topic Ophthalmology Applications
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395477/
https://www.ncbi.nlm.nih.gov/pubmed/22808424
http://dx.doi.org/10.1364/BOE.3.001506
work_keys_str_mv AT ruggerimarco imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch
AT uhlhornstephenr imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch
AT defreitascarolina imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch
AT hoarthur imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch
AT mannsfabrice imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch
AT pareljeanmarie imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch