Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch
Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395477/ https://www.ncbi.nlm.nih.gov/pubmed/22808424 http://dx.doi.org/10.1364/BOE.3.001506 |
_version_ | 1782237984548978688 |
---|---|
author | Ruggeri, Marco Uhlhorn, Stephen R. De Freitas, Carolina Ho, Arthur Manns, Fabrice Parel, Jean-Marie |
author_facet | Ruggeri, Marco Uhlhorn, Stephen R. De Freitas, Carolina Ho, Arthur Manns, Fabrice Parel, Jean-Marie |
author_sort | Ruggeri, Marco |
collection | PubMed |
description | Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time. |
format | Online Article Text |
id | pubmed-3395477 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-33954772012-07-17 Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch Ruggeri, Marco Uhlhorn, Stephen R. De Freitas, Carolina Ho, Arthur Manns, Fabrice Parel, Jean-Marie Biomed Opt Express Ophthalmology Applications Abstract: An optical switch was implemented in the reference arm of an extended depth SD-OCT system to sequentially acquire OCT images at different depths into the eye ranging from the cornea to the retina. A custom-made accommodation module was coupled with the delivery of the OCT system to provide controlled step stimuli of accommodation and disaccommodation that preserve ocular alignment. The changes in the lens shape were imaged and ocular distances were dynamically measured during accommodation and disaccommodation. The system is capable of dynamic in vivo imaging of the entire anterior segment and eye-length measurement during accommodation in real-time. Optical Society of America 2012-06-06 /pmc/articles/PMC3395477/ /pubmed/22808424 http://dx.doi.org/10.1364/BOE.3.001506 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Ophthalmology Applications Ruggeri, Marco Uhlhorn, Stephen R. De Freitas, Carolina Ho, Arthur Manns, Fabrice Parel, Jean-Marie Imaging and full-length biometry of the eye during accommodation using spectral domain OCT with an optical switch |
title | Imaging and full-length biometry of the eye during accommodation using spectral
domain OCT with an optical switch |
title_full | Imaging and full-length biometry of the eye during accommodation using spectral
domain OCT with an optical switch |
title_fullStr | Imaging and full-length biometry of the eye during accommodation using spectral
domain OCT with an optical switch |
title_full_unstemmed | Imaging and full-length biometry of the eye during accommodation using spectral
domain OCT with an optical switch |
title_short | Imaging and full-length biometry of the eye during accommodation using spectral
domain OCT with an optical switch |
title_sort | imaging and full-length biometry of the eye during accommodation using spectral
domain oct with an optical switch |
topic | Ophthalmology Applications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395477/ https://www.ncbi.nlm.nih.gov/pubmed/22808424 http://dx.doi.org/10.1364/BOE.3.001506 |
work_keys_str_mv | AT ruggerimarco imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch AT uhlhornstephenr imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch AT defreitascarolina imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch AT hoarthur imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch AT mannsfabrice imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch AT pareljeanmarie imagingandfulllengthbiometryoftheeyeduringaccommodationusingspectraldomainoctwithanopticalswitch |