Cargando…
Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial
BACKGROUND: Health utility (HU) measures are used as overall measures of quality of life and to determine quality adjusted life years (QALYs) in economic analyses. We compared baseline values of three HUs including Short Form 6 Dimensions (SF-6D), and Health Utilities Index, Mark II and Mark III (HU...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395556/ https://www.ncbi.nlm.nih.gov/pubmed/22515638 http://dx.doi.org/10.1186/1475-2840-11-35 |
_version_ | 1782237989952290816 |
---|---|
author | Raisch, Dennis W Feeney, Patricia Goff, David C Narayan, KM Venkat O’Connor, Patrick J Zhang, Ping Hire, Don G Sullivan, Mark D |
author_facet | Raisch, Dennis W Feeney, Patricia Goff, David C Narayan, KM Venkat O’Connor, Patrick J Zhang, Ping Hire, Don G Sullivan, Mark D |
author_sort | Raisch, Dennis W |
collection | PubMed |
description | BACKGROUND: Health utility (HU) measures are used as overall measures of quality of life and to determine quality adjusted life years (QALYs) in economic analyses. We compared baseline values of three HUs including Short Form 6 Dimensions (SF-6D), and Health Utilities Index, Mark II and Mark III (HUI2 and HUI3) and the feeling thermometer (FT) among type 2 diabetes participants in the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. We assessed relationships between HU and FT values and patient demographics and clinical variables. METHODS: ACCORD was a randomized clinical trial to test if intensive controls of glucose, blood pressure and lipids can reduce the risk of major cardiovascular disease (CVD) events in type 2 diabetes patients with high risk of CVD. The health-related quality of life (HRQOL) sub-study includes 2,053 randomly selected participants. Interclass correlations (ICCs) and agreement between measures by quartile were used to evaluate relationships between HU’s and the FT. Multivariable regression models specified relationships between patient variables and each HU and the FT. RESULTS: The ICCs were 0.245 for FT/SF-6D, 0.313 for HUI3/SF-6D, 0.437 for HUI2/SF-6D, 0.338 for FT/HUI2, 0.337 for FT/HUI3 and 0.751 for HUI2/HUI3 (P < 0.001 for all). Common classification by quartile was found for the majority (62%) of values between HUI2 and HUI3, which was significantly (P < 0.001) higher than between other HUs and the FT: SF-6D/HUI3 = 40.8%, SF-6D/HUI2 = 40.9%, FT/HUI3 = 35.0%, FT/HUI2 = 34.9%, and FT/SF-6D = 31.9%. Common classification was higher between SF-6D/HUI2 and SF-6D/HUI3 (P < 0.001) than between FT/SF-6D, FT/HUI2, and FT/HUI3. The mean difference in HU values per patient ranged from −0.024 ± 0.225 for SF-6D/ HUI3 to −0.124 ± 0.133 for SF-6D/HUI2. Regression models were significant; clinical and demographic variables explained 6.1% (SF-6D) to 7.7% (HUI3) of the variance in HUs. CONCLUSIONS: The agreements between the different HUs were poor except for the two HUI measures; therefore HU values derived different measures may not be comparable. The FT had low agreement with HUs. The relationships between HUs and demographic and clinical measures demonstrate how severity of diabetes and other clinical and demographic factors are associated with HUs and FT measures. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00000620 |
format | Online Article Text |
id | pubmed-3395556 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-33955562012-07-13 Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial Raisch, Dennis W Feeney, Patricia Goff, David C Narayan, KM Venkat O’Connor, Patrick J Zhang, Ping Hire, Don G Sullivan, Mark D Cardiovasc Diabetol Original Investigation BACKGROUND: Health utility (HU) measures are used as overall measures of quality of life and to determine quality adjusted life years (QALYs) in economic analyses. We compared baseline values of three HUs including Short Form 6 Dimensions (SF-6D), and Health Utilities Index, Mark II and Mark III (HUI2 and HUI3) and the feeling thermometer (FT) among type 2 diabetes participants in the Action to Control Cardiovascular Risk in Diabetes (ACCORD) trial. We assessed relationships between HU and FT values and patient demographics and clinical variables. METHODS: ACCORD was a randomized clinical trial to test if intensive controls of glucose, blood pressure and lipids can reduce the risk of major cardiovascular disease (CVD) events in type 2 diabetes patients with high risk of CVD. The health-related quality of life (HRQOL) sub-study includes 2,053 randomly selected participants. Interclass correlations (ICCs) and agreement between measures by quartile were used to evaluate relationships between HU’s and the FT. Multivariable regression models specified relationships between patient variables and each HU and the FT. RESULTS: The ICCs were 0.245 for FT/SF-6D, 0.313 for HUI3/SF-6D, 0.437 for HUI2/SF-6D, 0.338 for FT/HUI2, 0.337 for FT/HUI3 and 0.751 for HUI2/HUI3 (P < 0.001 for all). Common classification by quartile was found for the majority (62%) of values between HUI2 and HUI3, which was significantly (P < 0.001) higher than between other HUs and the FT: SF-6D/HUI3 = 40.8%, SF-6D/HUI2 = 40.9%, FT/HUI3 = 35.0%, FT/HUI2 = 34.9%, and FT/SF-6D = 31.9%. Common classification was higher between SF-6D/HUI2 and SF-6D/HUI3 (P < 0.001) than between FT/SF-6D, FT/HUI2, and FT/HUI3. The mean difference in HU values per patient ranged from −0.024 ± 0.225 for SF-6D/ HUI3 to −0.124 ± 0.133 for SF-6D/HUI2. Regression models were significant; clinical and demographic variables explained 6.1% (SF-6D) to 7.7% (HUI3) of the variance in HUs. CONCLUSIONS: The agreements between the different HUs were poor except for the two HUI measures; therefore HU values derived different measures may not be comparable. The FT had low agreement with HUs. The relationships between HUs and demographic and clinical measures demonstrate how severity of diabetes and other clinical and demographic factors are associated with HUs and FT measures. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT00000620 BioMed Central 2012-07-11 /pmc/articles/PMC3395556/ /pubmed/22515638 http://dx.doi.org/10.1186/1475-2840-11-35 Text en Copyright ©2012 Raisch et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Investigation Raisch, Dennis W Feeney, Patricia Goff, David C Narayan, KM Venkat O’Connor, Patrick J Zhang, Ping Hire, Don G Sullivan, Mark D Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
title | Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
title_full | Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
title_fullStr | Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
title_full_unstemmed | Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
title_short | Baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
title_sort | baseline comparison of three health utility measures and the feeling thermometer among participants in the action to control cardiovascular risk in diabetes trial |
topic | Original Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395556/ https://www.ncbi.nlm.nih.gov/pubmed/22515638 http://dx.doi.org/10.1186/1475-2840-11-35 |
work_keys_str_mv | AT raischdennisw baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT feeneypatricia baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT goffdavidc baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT narayankmvenkat baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT oconnorpatrickj baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT zhangping baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT hiredong baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial AT sullivanmarkd baselinecomparisonofthreehealthutilitymeasuresandthefeelingthermometeramongparticipantsintheactiontocontrolcardiovascularriskindiabetestrial |