Cargando…
Comparison of cement pressurisation in flanged and unflanged acetabular cups
BACKGROUND: This biomechanical study examined difference in cement pressures generated by flanged and unflanged acetabular cups in hip arthroplasty. METHOD: Using a model acetabulum, cement was inserted and pressurised followed by cup insertion and pressurisation. Pressures were recorded using trans...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395818/ https://www.ncbi.nlm.nih.gov/pubmed/22305294 http://dx.doi.org/10.1186/1749-799X-7-5 |
_version_ | 1782238038456270848 |
---|---|
author | Bhattacharya, Rajarshi Attar, Fahad G Green, Sarah Port, Andrew |
author_facet | Bhattacharya, Rajarshi Attar, Fahad G Green, Sarah Port, Andrew |
author_sort | Bhattacharya, Rajarshi |
collection | PubMed |
description | BACKGROUND: This biomechanical study examined difference in cement pressures generated by flanged and unflanged acetabular cups in hip arthroplasty. METHOD: Using a model acetabulum, cement was inserted and pressurised followed by cup insertion and pressurisation. Pressures were recorded using transducers in the acetabulum. We compared Charnley Ogee (flanged), Exeter contemporary (flanged) and Exeter low profile (unflanged) cups using Simplex and CMW1 cements in turn. RESULTS: Using Simplex, Charnley Ogee cup generated highest initial peak pressure and overall mean pressure. Exeter unflanged cup generated higher initial and mean pressures compared to Exeter flanged cup. With CMW, there was no significant difference between the pressures generated by the cups. CONCLUSIONS: Our experiment suggests that flanged cups do not consistently generate significantly higher cement pressures compared to unflanged cups. |
format | Online Article Text |
id | pubmed-3395818 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-33958182012-07-14 Comparison of cement pressurisation in flanged and unflanged acetabular cups Bhattacharya, Rajarshi Attar, Fahad G Green, Sarah Port, Andrew J Orthop Surg Res Research Article BACKGROUND: This biomechanical study examined difference in cement pressures generated by flanged and unflanged acetabular cups in hip arthroplasty. METHOD: Using a model acetabulum, cement was inserted and pressurised followed by cup insertion and pressurisation. Pressures were recorded using transducers in the acetabulum. We compared Charnley Ogee (flanged), Exeter contemporary (flanged) and Exeter low profile (unflanged) cups using Simplex and CMW1 cements in turn. RESULTS: Using Simplex, Charnley Ogee cup generated highest initial peak pressure and overall mean pressure. Exeter unflanged cup generated higher initial and mean pressures compared to Exeter flanged cup. With CMW, there was no significant difference between the pressures generated by the cups. CONCLUSIONS: Our experiment suggests that flanged cups do not consistently generate significantly higher cement pressures compared to unflanged cups. BioMed Central 2012-02-03 /pmc/articles/PMC3395818/ /pubmed/22305294 http://dx.doi.org/10.1186/1749-799X-7-5 Text en Copyright ©2012 Bhattacharya et al; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bhattacharya, Rajarshi Attar, Fahad G Green, Sarah Port, Andrew Comparison of cement pressurisation in flanged and unflanged acetabular cups |
title | Comparison of cement pressurisation in flanged and unflanged acetabular cups |
title_full | Comparison of cement pressurisation in flanged and unflanged acetabular cups |
title_fullStr | Comparison of cement pressurisation in flanged and unflanged acetabular cups |
title_full_unstemmed | Comparison of cement pressurisation in flanged and unflanged acetabular cups |
title_short | Comparison of cement pressurisation in flanged and unflanged acetabular cups |
title_sort | comparison of cement pressurisation in flanged and unflanged acetabular cups |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3395818/ https://www.ncbi.nlm.nih.gov/pubmed/22305294 http://dx.doi.org/10.1186/1749-799X-7-5 |
work_keys_str_mv | AT bhattacharyarajarshi comparisonofcementpressurisationinflangedandunflangedacetabularcups AT attarfahadg comparisonofcementpressurisationinflangedandunflangedacetabularcups AT greensarah comparisonofcementpressurisationinflangedandunflangedacetabularcups AT portandrew comparisonofcementpressurisationinflangedandunflangedacetabularcups |