Cargando…

A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model

Achieving accurate intracranial electrode or catheter placement is critical in clinical practice in order to maximise the efficacy of deep brain stimulation and drug delivery respectively as well as to minimise side-effects. We have developed a highly accurate and robust method for MRI-guided, stere...

Descripción completa

Detalles Bibliográficos
Autores principales: White, E., Woolley, M., Bienemann, A., Johnson, D.E., Wyatt, M., Murray, G., Taylor, H., Gill, S.S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier/North-Holland Biomedical Press 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3396852/
https://www.ncbi.nlm.nih.gov/pubmed/21074564
http://dx.doi.org/10.1016/j.jneumeth.2010.10.023
_version_ 1782238143776292864
author White, E.
Woolley, M.
Bienemann, A.
Johnson, D.E.
Wyatt, M.
Murray, G.
Taylor, H.
Gill, S.S.
author_facet White, E.
Woolley, M.
Bienemann, A.
Johnson, D.E.
Wyatt, M.
Murray, G.
Taylor, H.
Gill, S.S.
author_sort White, E.
collection PubMed
description Achieving accurate intracranial electrode or catheter placement is critical in clinical practice in order to maximise the efficacy of deep brain stimulation and drug delivery respectively as well as to minimise side-effects. We have developed a highly accurate and robust method for MRI-guided, stereotactic delivery of catheters and electrodes to deep target structures in the brain of pigs. This study outlines the development of this equipment and animal model. Specifically this system enables reliable head immobilisation, acquisition of high-resolution MR images, precise co-registration of MRI and stereotactic spaces and overall rigidity to facilitate accurate burr hole-generation and catheter implantation. To demonstrate the utility of this system, in this study a total of twelve catheters were implanted into the putamen of six Large White Landrace pigs. All implants were accurately placed into the putamen. Target accuracy had a mean Euclidean distance of 0.623 mm (standard deviation of 0.33 mm). This method has allowed us to accurately insert fine cannulae, suitable for the administration of therapeutic agents by convection-enhanced delivery (CED), into the brain of pigs. This study provides summary evidence of a robust system for catheter implantation into the brain of a large animal model. We are currently using this stereotactic system, implantation procedure and animal model to develop catheter-based drug delivery systems that will be translated into human clinical trials, as well as to model the distribution of therapeutic agents administered by CED over large volumes of brain.
format Online
Article
Text
id pubmed-3396852
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Elsevier/North-Holland Biomedical Press
record_format MEDLINE/PubMed
spelling pubmed-33968522012-07-24 A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model White, E. Woolley, M. Bienemann, A. Johnson, D.E. Wyatt, M. Murray, G. Taylor, H. Gill, S.S. J Neurosci Methods Article Achieving accurate intracranial electrode or catheter placement is critical in clinical practice in order to maximise the efficacy of deep brain stimulation and drug delivery respectively as well as to minimise side-effects. We have developed a highly accurate and robust method for MRI-guided, stereotactic delivery of catheters and electrodes to deep target structures in the brain of pigs. This study outlines the development of this equipment and animal model. Specifically this system enables reliable head immobilisation, acquisition of high-resolution MR images, precise co-registration of MRI and stereotactic spaces and overall rigidity to facilitate accurate burr hole-generation and catheter implantation. To demonstrate the utility of this system, in this study a total of twelve catheters were implanted into the putamen of six Large White Landrace pigs. All implants were accurately placed into the putamen. Target accuracy had a mean Euclidean distance of 0.623 mm (standard deviation of 0.33 mm). This method has allowed us to accurately insert fine cannulae, suitable for the administration of therapeutic agents by convection-enhanced delivery (CED), into the brain of pigs. This study provides summary evidence of a robust system for catheter implantation into the brain of a large animal model. We are currently using this stereotactic system, implantation procedure and animal model to develop catheter-based drug delivery systems that will be translated into human clinical trials, as well as to model the distribution of therapeutic agents administered by CED over large volumes of brain. Elsevier/North-Holland Biomedical Press 2011-01-30 /pmc/articles/PMC3396852/ /pubmed/21074564 http://dx.doi.org/10.1016/j.jneumeth.2010.10.023 Text en © 2011 Elsevier B.V. https://creativecommons.org/licenses/by/3.0/ Open Access under CC BY 3.0 (https://creativecommons.org/licenses/by/3.0/) license
spellingShingle Article
White, E.
Woolley, M.
Bienemann, A.
Johnson, D.E.
Wyatt, M.
Murray, G.
Taylor, H.
Gill, S.S.
A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
title A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
title_full A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
title_fullStr A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
title_full_unstemmed A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
title_short A robust MRI-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
title_sort robust mri-compatible system to facilitate highly accurate stereotactic administration of therapeutic agents to targets within the brain of a large animal model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3396852/
https://www.ncbi.nlm.nih.gov/pubmed/21074564
http://dx.doi.org/10.1016/j.jneumeth.2010.10.023
work_keys_str_mv AT whitee arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT woolleym arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT bienemanna arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT johnsonde arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT wyattm arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT murrayg arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT taylorh arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT gillss arobustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT whitee robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT woolleym robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT bienemanna robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT johnsonde robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT wyattm robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT murrayg robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT taylorh robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel
AT gillss robustmricompatiblesystemtofacilitatehighlyaccuratestereotacticadministrationoftherapeuticagentstotargetswithinthebrainofalargeanimalmodel