Cargando…

Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes

OBJECTIVE: To determine the utility of pulse pressure variation (Δ(RESP)PP) in predicting fluid responsiveness in patients ventilated with low tidal volumes (V(T)) and to investigate whether a lower Δ(RESP)PP cut-off value should be used when patients are ventilated with low tidal volumes. METHOD: T...

Descripción completa

Detalles Bibliográficos
Autores principales: de Oliveira-Costa, Clarice Daniele Alves, Friedman, Gilberto, Vieira, Sílvia Regina Rios, Fialkow, Léa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3400168/
https://www.ncbi.nlm.nih.gov/pubmed/22892922
http://dx.doi.org/10.6061/clinics/2012(07)12
_version_ 1782238466185101312
author de Oliveira-Costa, Clarice Daniele Alves
Friedman, Gilberto
Vieira, Sílvia Regina Rios
Fialkow, Léa
author_facet de Oliveira-Costa, Clarice Daniele Alves
Friedman, Gilberto
Vieira, Sílvia Regina Rios
Fialkow, Léa
author_sort de Oliveira-Costa, Clarice Daniele Alves
collection PubMed
description OBJECTIVE: To determine the utility of pulse pressure variation (Δ(RESP)PP) in predicting fluid responsiveness in patients ventilated with low tidal volumes (V(T)) and to investigate whether a lower Δ(RESP)PP cut-off value should be used when patients are ventilated with low tidal volumes. METHOD: This cross-sectional observational study included 37 critically ill patients with acute circulatory failure who required fluid challenge. The patients were sedated and mechanically ventilated with a V(T) of 6-7 ml/kg ideal body weight, which was monitored with a pulmonary artery catheter and an arterial line. The mechanical ventilation and hemodynamic parameters, including Δ(RESP)PP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase in the cardiac index of at least 15%. ClinicalTrial.gov: NCT01569308. RESULTS: A total of 17 patients were classified as responders. Analysis of the area under the ROC curve (AUC) showed that the optimal cut-off point for Δ(RESP)PP to predict fluid responsiveness was 10% (AUC = 0.74). Adjustment of the Δ(RESP)PP to account for driving pressure did not improve the accuracy (AUC = 0.76). A Δ(RESP)PP≥10% was a better predictor of fluid responsiveness than central venous pressure (AUC = 0.57) or pulmonary wedge pressure (AUC = 051). Of the 37 patients, 25 were in septic shock. The AUC for Δ(RESP)PP≥10% to predict responsiveness in patients with septic shock was 0.84 (sensitivity, 78%; specificity, 93%). CONCLUSION: The parameter Δ(RESP)PP has limited value in predicting fluid responsiveness in patients who are ventilated with low tidal volumes, but a Δ(RESP)PP>10% is a significant improvement over static parameters. A Δ(RESP)PP≥10% may be particularly useful for identifying responders in patients with septic shock.
format Online
Article
Text
id pubmed-3400168
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo
record_format MEDLINE/PubMed
spelling pubmed-34001682012-07-20 Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes de Oliveira-Costa, Clarice Daniele Alves Friedman, Gilberto Vieira, Sílvia Regina Rios Fialkow, Léa Clinics (Sao Paulo) Clinical Science OBJECTIVE: To determine the utility of pulse pressure variation (Δ(RESP)PP) in predicting fluid responsiveness in patients ventilated with low tidal volumes (V(T)) and to investigate whether a lower Δ(RESP)PP cut-off value should be used when patients are ventilated with low tidal volumes. METHOD: This cross-sectional observational study included 37 critically ill patients with acute circulatory failure who required fluid challenge. The patients were sedated and mechanically ventilated with a V(T) of 6-7 ml/kg ideal body weight, which was monitored with a pulmonary artery catheter and an arterial line. The mechanical ventilation and hemodynamic parameters, including Δ(RESP)PP, were measured before and after fluid challenge with 1,000 ml crystalloids or 500 ml colloids. Fluid responsiveness was defined as an increase in the cardiac index of at least 15%. ClinicalTrial.gov: NCT01569308. RESULTS: A total of 17 patients were classified as responders. Analysis of the area under the ROC curve (AUC) showed that the optimal cut-off point for Δ(RESP)PP to predict fluid responsiveness was 10% (AUC = 0.74). Adjustment of the Δ(RESP)PP to account for driving pressure did not improve the accuracy (AUC = 0.76). A Δ(RESP)PP≥10% was a better predictor of fluid responsiveness than central venous pressure (AUC = 0.57) or pulmonary wedge pressure (AUC = 051). Of the 37 patients, 25 were in septic shock. The AUC for Δ(RESP)PP≥10% to predict responsiveness in patients with septic shock was 0.84 (sensitivity, 78%; specificity, 93%). CONCLUSION: The parameter Δ(RESP)PP has limited value in predicting fluid responsiveness in patients who are ventilated with low tidal volumes, but a Δ(RESP)PP>10% is a significant improvement over static parameters. A Δ(RESP)PP≥10% may be particularly useful for identifying responders in patients with septic shock. Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo 2012-07 /pmc/articles/PMC3400168/ /pubmed/22892922 http://dx.doi.org/10.6061/clinics/2012(07)12 Text en Copyright © 2012 Hospital das Clínicas da FMUSP http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Clinical Science
de Oliveira-Costa, Clarice Daniele Alves
Friedman, Gilberto
Vieira, Sílvia Regina Rios
Fialkow, Léa
Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
title Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
title_full Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
title_fullStr Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
title_full_unstemmed Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
title_short Pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
title_sort pulse pressure variation and prediction of fluid responsiveness in patients ventilated with low tidal volumes
topic Clinical Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3400168/
https://www.ncbi.nlm.nih.gov/pubmed/22892922
http://dx.doi.org/10.6061/clinics/2012(07)12
work_keys_str_mv AT deoliveiracostaclaricedanielealves pulsepressurevariationandpredictionoffluidresponsivenessinpatientsventilatedwithlowtidalvolumes
AT friedmangilberto pulsepressurevariationandpredictionoffluidresponsivenessinpatientsventilatedwithlowtidalvolumes
AT vieirasilviareginarios pulsepressurevariationandpredictionoffluidresponsivenessinpatientsventilatedwithlowtidalvolumes
AT fialkowlea pulsepressurevariationandpredictionoffluidresponsivenessinpatientsventilatedwithlowtidalvolumes