Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI
INTRODUCTION: We analyze our preliminary experience using the PoleStar N20 mobile intraoperative MR (iMR) system as an adjunct for pediatric brain tumor resection. METHODS: We analyzed 11 resections in nine children between 1 month and 17 years old. After resection, we acquired iMR scans to detect r...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer-Verlag
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3402673/ https://www.ncbi.nlm.nih.gov/pubmed/22684477 http://dx.doi.org/10.1007/s00381-012-1815-8 |
_version_ | 1782238778917650432 |
---|---|
author | Kubben, P. L. van Santbrink, H. ter Laak-Poort, M. Weber, J. W. Vles, J. S. H. Granzen, B. van Overbeeke, J. J. Cornips, E. M. J. |
author_facet | Kubben, P. L. van Santbrink, H. ter Laak-Poort, M. Weber, J. W. Vles, J. S. H. Granzen, B. van Overbeeke, J. J. Cornips, E. M. J. |
author_sort | Kubben, P. L. |
collection | PubMed |
description | INTRODUCTION: We analyze our preliminary experience using the PoleStar N20 mobile intraoperative MR (iMR) system as an adjunct for pediatric brain tumor resection. METHODS: We analyzed 11 resections in nine children between 1 month and 17 years old. After resection, we acquired iMR scans to detect residual tumor and update neuronavigation. We compared final iMR interpretation by the neurosurgeon with early postoperative MR interpretation by a neuroradiologist. RESULTS: Patient positioning was straightforward, and image quality (T1 7-min 4-mm sequences) sufficient in all cases. In five cases, contrast enhancement suspect for residual tumor was noted on initial postresection iMR images. In one case, a slight discrepancy with postoperative imaging after 3 months was no longer visible after 1 year. No serious perioperative adverse events related to the PoleStar N20 were encountered, except for transient shoulder pain in two. CONCLUSIONS: Using the PoleStar N20 iMR system is technically feasible and safe for both supra- and infratentorial tumor resections in children of all ages. Their small head and shoulders favor positioning in the magnet bore and allow the field of view to cover more than the area of primary interest, e.g., the ventricles in an infratentorial case. Standard surgical equipment may be used without significant limitations. In this series, the use of iMR leads to an increased extent of tumor resection in 45 % of cases. Correlation between iMR and early postoperative MR is excellent, provided image quality is optimal and interpretation is carefully done by someone sufficiently familiar with the system. |
format | Online Article Text |
id | pubmed-3402673 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Springer-Verlag |
record_format | MEDLINE/PubMed |
spelling | pubmed-34026732012-07-26 Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI Kubben, P. L. van Santbrink, H. ter Laak-Poort, M. Weber, J. W. Vles, J. S. H. Granzen, B. van Overbeeke, J. J. Cornips, E. M. J. Childs Nerv Syst Original Paper INTRODUCTION: We analyze our preliminary experience using the PoleStar N20 mobile intraoperative MR (iMR) system as an adjunct for pediatric brain tumor resection. METHODS: We analyzed 11 resections in nine children between 1 month and 17 years old. After resection, we acquired iMR scans to detect residual tumor and update neuronavigation. We compared final iMR interpretation by the neurosurgeon with early postoperative MR interpretation by a neuroradiologist. RESULTS: Patient positioning was straightforward, and image quality (T1 7-min 4-mm sequences) sufficient in all cases. In five cases, contrast enhancement suspect for residual tumor was noted on initial postresection iMR images. In one case, a slight discrepancy with postoperative imaging after 3 months was no longer visible after 1 year. No serious perioperative adverse events related to the PoleStar N20 were encountered, except for transient shoulder pain in two. CONCLUSIONS: Using the PoleStar N20 iMR system is technically feasible and safe for both supra- and infratentorial tumor resections in children of all ages. Their small head and shoulders favor positioning in the magnet bore and allow the field of view to cover more than the area of primary interest, e.g., the ventricles in an infratentorial case. Standard surgical equipment may be used without significant limitations. In this series, the use of iMR leads to an increased extent of tumor resection in 45 % of cases. Correlation between iMR and early postoperative MR is excellent, provided image quality is optimal and interpretation is carefully done by someone sufficiently familiar with the system. Springer-Verlag 2012-06-10 2012 /pmc/articles/PMC3402673/ /pubmed/22684477 http://dx.doi.org/10.1007/s00381-012-1815-8 Text en © The Author(s) 2012 https://creativecommons.org/licenses/by/4.0/ This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited. |
spellingShingle | Original Paper Kubben, P. L. van Santbrink, H. ter Laak-Poort, M. Weber, J. W. Vles, J. S. H. Granzen, B. van Overbeeke, J. J. Cornips, E. M. J. Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI |
title | Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI |
title_full | Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI |
title_fullStr | Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI |
title_full_unstemmed | Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI |
title_short | Implementation of a mobile 0.15-T intraoperative MR system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength MRI |
title_sort | implementation of a mobile 0.15-t intraoperative mr system in pediatric neuro-oncological surgery: feasibility and correlation with early postoperative high-field strength mri |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3402673/ https://www.ncbi.nlm.nih.gov/pubmed/22684477 http://dx.doi.org/10.1007/s00381-012-1815-8 |
work_keys_str_mv | AT kubbenpl implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT vansantbrinkh implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT terlaakpoortm implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT weberjw implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT vlesjsh implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT granzenb implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT vanoverbeekejj implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri AT cornipsemj implementationofamobile015tintraoperativemrsysteminpediatricneurooncologicalsurgeryfeasibilityandcorrelationwithearlypostoperativehighfieldstrengthmri |