Cargando…

Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh

BACKGROUND: Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorpor...

Descripción completa

Detalles Bibliográficos
Autores principales: Massullo, James M., Singh, Tejinder P., Dunnican, Ward J., Binetti, Brian R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3407458/
https://www.ncbi.nlm.nih.gov/pubmed/22906331
http://dx.doi.org/10.4293/108680812X13291597715943
_version_ 1782239333602820096
author Massullo, James M.
Singh, Tejinder P.
Dunnican, Ward J.
Binetti, Brian R.
author_facet Massullo, James M.
Singh, Tejinder P.
Dunnican, Ward J.
Binetti, Brian R.
author_sort Massullo, James M.
collection PubMed
description BACKGROUND: Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data. METHODS: Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy. RESULTS: Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia. CONCLUSIONS: In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted.
format Online
Article
Text
id pubmed-3407458
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-34074582012-08-13 Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh Massullo, James M. Singh, Tejinder P. Dunnican, Ward J. Binetti, Brian R. JSLS Scientific Papers BACKGROUND: Repairing large hiatal hernias using mesh has been shown to reduce recurrence. Drawbacks to mesh include added time to place and secure the prosthesis as well as complications such as esophageal erosion. We used a laparoscopic technique for repair of hiatal hernias (HH) >5cm, incorporating primary crural repair with onlay fixation of a synthetic polyglycolicacid:trimethylene carbonate (PGA:TMC) absorbable tissue reinforcement. The purpose of this report is to present short-term follow-up data. METHODS: Patients with hiatal hernia types I-III and defects >5cm were included. Primary closure of the hernia defect was performed using interrupted nonpledgeted sutures, followed by PGA:TMC mesh onlay fixed with absorbable tacks. A fundoplication was then performed. Evaluation of patients was carried out at routine follow-up visits. Outcomes measured were symptoms of gastroesophageal reflux disease (GERD), or other symptoms suspicious for recurrence. Patients exhibiting these complaints underwent further evaluation including radiographic imaging and endoscopy. RESULTS: Follow-up data were analyzed on 11 patients. Two patients were male; 9 were female. The mean age was 60 years. The mean length of follow-up was 13 months. There were no complications related to the mesh. One patient suffered from respiratory failure, one from gas bloat syndrome, and another had a superficial port-site infection. One patient developed a recurrent hiatal hernia. CONCLUSIONS: In this small series, laparoscopic repair of hiatal hernias >5cm with onlay fixation of PGA:TMC tissue reinforcement has short-term outcomes with a reasonably low recurrence rate. However, due to the preliminary and nonrandomized nature of the data, no strong comparison can be made with other types of mesh repairs. Additional data collection is warranted. Society of Laparoendoscopic Surgeons 2012 /pmc/articles/PMC3407458/ /pubmed/22906331 http://dx.doi.org/10.4293/108680812X13291597715943 Text en © 2012 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Massullo, James M.
Singh, Tejinder P.
Dunnican, Ward J.
Binetti, Brian R.
Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
title Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
title_full Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
title_fullStr Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
title_full_unstemmed Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
title_short Preliminary Study of Hiatal Hernia Repair Using Polyglycolic Acid: Trimethylene Carbonate Mesh
title_sort preliminary study of hiatal hernia repair using polyglycolic acid: trimethylene carbonate mesh
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3407458/
https://www.ncbi.nlm.nih.gov/pubmed/22906331
http://dx.doi.org/10.4293/108680812X13291597715943
work_keys_str_mv AT massullojamesm preliminarystudyofhiatalherniarepairusingpolyglycolicacidtrimethylenecarbonatemesh
AT singhtejinderp preliminarystudyofhiatalherniarepairusingpolyglycolicacidtrimethylenecarbonatemesh
AT dunnicanwardj preliminarystudyofhiatalherniarepairusingpolyglycolicacidtrimethylenecarbonatemesh
AT binettibrianr preliminarystudyofhiatalherniarepairusingpolyglycolicacidtrimethylenecarbonatemesh