Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography

PURPOSE: To study choroidal thickness and its topographic profile in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography and the correlation with age and refractive error. METHODS: Fifty-seven eyes (45 individuals) with no visual complaints or ocular disease underwent horizont...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Joong Won, Shin, Yong Un, Cho, Hee Yoon, Lee, Byung Ro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3408529/
https://www.ncbi.nlm.nih.gov/pubmed/22870023
http://dx.doi.org/10.3341/kjo.2012.26.4.255
_version_ 1782239481745637376
author Shin, Joong Won
Shin, Yong Un
Cho, Hee Yoon
Lee, Byung Ro
author_facet Shin, Joong Won
Shin, Yong Un
Cho, Hee Yoon
Lee, Byung Ro
author_sort Shin, Joong Won
collection PubMed
description PURPOSE: To study choroidal thickness and its topographic profile in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography and the correlation with age and refractive error. METHODS: Fifty-seven eyes (45 individuals) with no visual complaints or ocular disease underwent horizontal and vertical line scanning using 3D OCT-1000. The definition of choroidal thickness was the vertical distance between the posterior edge of the hyper-reflective retinal pigment epithelium and the choroid/sclera junction. Choroidal thickness was measured in the subfoveal area at 500 µm intervals from the fovea to 2,500 µm in the nasal, temporal, superior, and inferior regions. The spherical equivalent refractive error was measured by autorefractometry. Statistical analysis was used to confirm the correlations of choroidal thickness with age and refraction error. RESULTS: The mean age of the 45 participants (57 eyes) was 45.28 years. Detailed visualization of the choroid for measuring its thickness was possible in 63.3% of eyes. The mean subfoveal choroidal thickness was found to be 270.8 µm (standard deviation [SD], ±51 µm), in horizontal scanning and 275.0 µm (SD, ±49 µm) in vertical scanning. The temporal choroidal thickness was greater than any 500 µm interval in corresponding locations, and there was no significant difference between the superior and inferior choroid as far as 2,000 µm from the fovea. Age and refractive error were associated with subfoveal choroidal thickness in terms of regression (p < 0.05). CONCLUSIONS: Choroidal thickness in normal Korean eyes can be measured using 3D OCT-1000 with high resolution line scanning. The topographical profile of choroidal thickness varies depending on its location. Age and refractive error are essential factors for interpretation of choroidal thickness.
format Online
Article
Text
id pubmed-3408529
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-34085292012-08-07 Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography Shin, Joong Won Shin, Yong Un Cho, Hee Yoon Lee, Byung Ro Korean J Ophthalmol Original Article PURPOSE: To study choroidal thickness and its topographic profile in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography and the correlation with age and refractive error. METHODS: Fifty-seven eyes (45 individuals) with no visual complaints or ocular disease underwent horizontal and vertical line scanning using 3D OCT-1000. The definition of choroidal thickness was the vertical distance between the posterior edge of the hyper-reflective retinal pigment epithelium and the choroid/sclera junction. Choroidal thickness was measured in the subfoveal area at 500 µm intervals from the fovea to 2,500 µm in the nasal, temporal, superior, and inferior regions. The spherical equivalent refractive error was measured by autorefractometry. Statistical analysis was used to confirm the correlations of choroidal thickness with age and refraction error. RESULTS: The mean age of the 45 participants (57 eyes) was 45.28 years. Detailed visualization of the choroid for measuring its thickness was possible in 63.3% of eyes. The mean subfoveal choroidal thickness was found to be 270.8 µm (standard deviation [SD], ±51 µm), in horizontal scanning and 275.0 µm (SD, ±49 µm) in vertical scanning. The temporal choroidal thickness was greater than any 500 µm interval in corresponding locations, and there was no significant difference between the superior and inferior choroid as far as 2,000 µm from the fovea. Age and refractive error were associated with subfoveal choroidal thickness in terms of regression (p < 0.05). CONCLUSIONS: Choroidal thickness in normal Korean eyes can be measured using 3D OCT-1000 with high resolution line scanning. The topographical profile of choroidal thickness varies depending on its location. Age and refractive error are essential factors for interpretation of choroidal thickness. The Korean Ophthalmological Society 2012-08 2012-07-24 /pmc/articles/PMC3408529/ /pubmed/22870023 http://dx.doi.org/10.3341/kjo.2012.26.4.255 Text en © 2012 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Shin, Joong Won
Shin, Yong Un
Cho, Hee Yoon
Lee, Byung Ro
Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
title Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
title_full Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
title_fullStr Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
title_full_unstemmed Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
title_short Measurement of Choroidal Thickness in Normal Eyes Using 3D OCT-1000 Spectral Domain Optical Coherence Tomography
title_sort measurement of choroidal thickness in normal eyes using 3d oct-1000 spectral domain optical coherence tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3408529/
https://www.ncbi.nlm.nih.gov/pubmed/22870023
http://dx.doi.org/10.3341/kjo.2012.26.4.255
work_keys_str_mv AT shinjoongwon measurementofchoroidalthicknessinnormaleyesusing3doct1000spectraldomainopticalcoherencetomography
AT shinyongun measurementofchoroidalthicknessinnormaleyesusing3doct1000spectraldomainopticalcoherencetomography
AT choheeyoon measurementofchoroidalthicknessinnormaleyesusing3doct1000spectraldomainopticalcoherencetomography
AT leebyungro measurementofchoroidalthicknessinnormaleyesusing3doct1000spectraldomainopticalcoherencetomography