Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case

We present here a rare case of heterotopic ossification in interspinous/interlaminar Coflex device. The classical surgical indications for these implants are degenerative canal stenosis, discogenic low back pain, disk herniations, facet syndrome, and instability. However, fractures of spinous proces...

Descripción completa

Detalles Bibliográficos
Autores principales: Maida, Giuseppe, Marcati, Eleonora, Sarubbo, Silvio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3409525/
https://www.ncbi.nlm.nih.gov/pubmed/22888459
http://dx.doi.org/10.1155/2012/970642
_version_ 1782239602450366464
author Maida, Giuseppe
Marcati, Eleonora
Sarubbo, Silvio
author_facet Maida, Giuseppe
Marcati, Eleonora
Sarubbo, Silvio
author_sort Maida, Giuseppe
collection PubMed
description We present here a rare case of heterotopic ossification in interspinous/interlaminar Coflex device. The classical surgical indications for these implants are degenerative canal stenosis, discogenic low back pain, disk herniations, facet syndrome, and instability. However, fractures of spinous processes are a potential risk after interspinous/interlaminar devices' implantation. Recently, heterotopic ossification, a well-known complication of hip and knee arthroplasty, has been reported after cervical and lumbar prosthesis. We performed undercutting and implantation of the dynamic interspinous/interlaminar device to treat an adult male patient with L4-L5 stenosis. The patient underwent 45-day imaging and clinical followup, and we observed both a neurological and imaging improvement. A CT bone scan, performed 3 years after surgery for recurrence of neurogenic claudication, showed a new stenosis due to an abnormal ossification all over the device. To our knowledge, this is the first reported case of heterotopic ossification in an interspinous/interlaminar dynamic device. Accordingly, we aim to suggest it as a new complication of interspinous/interlaminar devices.
format Online
Article
Text
id pubmed-3409525
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-34095252012-08-10 Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case Maida, Giuseppe Marcati, Eleonora Sarubbo, Silvio Case Rep Surg Case Report We present here a rare case of heterotopic ossification in interspinous/interlaminar Coflex device. The classical surgical indications for these implants are degenerative canal stenosis, discogenic low back pain, disk herniations, facet syndrome, and instability. However, fractures of spinous processes are a potential risk after interspinous/interlaminar devices' implantation. Recently, heterotopic ossification, a well-known complication of hip and knee arthroplasty, has been reported after cervical and lumbar prosthesis. We performed undercutting and implantation of the dynamic interspinous/interlaminar device to treat an adult male patient with L4-L5 stenosis. The patient underwent 45-day imaging and clinical followup, and we observed both a neurological and imaging improvement. A CT bone scan, performed 3 years after surgery for recurrence of neurogenic claudication, showed a new stenosis due to an abnormal ossification all over the device. To our knowledge, this is the first reported case of heterotopic ossification in an interspinous/interlaminar dynamic device. Accordingly, we aim to suggest it as a new complication of interspinous/interlaminar devices. Hindawi Publishing Corporation 2012 2012-07-24 /pmc/articles/PMC3409525/ /pubmed/22888459 http://dx.doi.org/10.1155/2012/970642 Text en Copyright © 2012 Giuseppe Maida et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Maida, Giuseppe
Marcati, Eleonora
Sarubbo, Silvio
Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case
title Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case
title_full Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case
title_fullStr Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case
title_full_unstemmed Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case
title_short Heterotopic Ossification in Vertebral Interlaminar/Interspinous Instrumentation: Report of a Case
title_sort heterotopic ossification in vertebral interlaminar/interspinous instrumentation: report of a case
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3409525/
https://www.ncbi.nlm.nih.gov/pubmed/22888459
http://dx.doi.org/10.1155/2012/970642
work_keys_str_mv AT maidagiuseppe heterotopicossificationinvertebralinterlaminarinterspinousinstrumentationreportofacase
AT marcatieleonora heterotopicossificationinvertebralinterlaminarinterspinousinstrumentationreportofacase
AT sarubbosilvio heterotopicossificationinvertebralinterlaminarinterspinousinstrumentationreportofacase