Cargando…
Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) c...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Optical Society of America
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3409712/ https://www.ncbi.nlm.nih.gov/pubmed/22876357 http://dx.doi.org/10.1364/BOE.3.001947 |
_version_ | 1782239626369433600 |
---|---|
author | Tan, K. M. Shishkov, M. Chee, A. Applegate, M. B. Bouma, B. E. Suter, M. J. |
author_facet | Tan, K. M. Shishkov, M. Chee, A. Applegate, M. B. Bouma, B. E. Suter, M. J. |
author_sort | Tan, K. M. |
collection | PubMed |
description | Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) catheter that functions as a “smart needle” to confirm the needle placement within the target lesion prior to biopsy. The TB-OFDI smart needle consists of a flexible and removable OFDI catheter (430 µm dia.) that operates within a standard 21-gauge TBNA needle. The OFDI imaging core is based on an angle polished ball lens design with a working distance of 160 µm from the catheter sheath and a spot size of 25 µm. To demonstrate the potential of the TB-OFDI smart needle for transbronchial imaging, an inflated excised swine lung was imaged through a standard bronchoscope. Cross-sectional and longitudinal OFDI results reveal the detailed network of alveoli in the lung parenchyma suggesting that the TB-OFDI smart needle may be a useful tool for guiding biopsy acquisition to increase the diagnostic yield. |
format | Online Article Text |
id | pubmed-3409712 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Optical Society of America |
record_format | MEDLINE/PubMed |
spelling | pubmed-34097122012-08-08 Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance Tan, K. M. Shishkov, M. Chee, A. Applegate, M. B. Bouma, B. E. Suter, M. J. Biomed Opt Express Endoscopes, Catheters and Micro-Optics Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) catheter that functions as a “smart needle” to confirm the needle placement within the target lesion prior to biopsy. The TB-OFDI smart needle consists of a flexible and removable OFDI catheter (430 µm dia.) that operates within a standard 21-gauge TBNA needle. The OFDI imaging core is based on an angle polished ball lens design with a working distance of 160 µm from the catheter sheath and a spot size of 25 µm. To demonstrate the potential of the TB-OFDI smart needle for transbronchial imaging, an inflated excised swine lung was imaged through a standard bronchoscope. Cross-sectional and longitudinal OFDI results reveal the detailed network of alveoli in the lung parenchyma suggesting that the TB-OFDI smart needle may be a useful tool for guiding biopsy acquisition to increase the diagnostic yield. Optical Society of America 2012-07-27 /pmc/articles/PMC3409712/ /pubmed/22876357 http://dx.doi.org/10.1364/BOE.3.001947 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially. |
spellingShingle | Endoscopes, Catheters and Micro-Optics Tan, K. M. Shishkov, M. Chee, A. Applegate, M. B. Bouma, B. E. Suter, M. J. Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
title | Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
title_full | Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
title_fullStr | Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
title_full_unstemmed | Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
title_short | Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
title_sort | flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance |
topic | Endoscopes, Catheters and Micro-Optics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3409712/ https://www.ncbi.nlm.nih.gov/pubmed/22876357 http://dx.doi.org/10.1364/BOE.3.001947 |
work_keys_str_mv | AT tankm flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance AT shishkovm flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance AT cheea flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance AT applegatemb flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance AT boumabe flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance AT sutermj flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance |