Cargando…

Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance

Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) c...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, K. M., Shishkov, M., Chee, A., Applegate, M. B., Bouma, B. E., Suter, M. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3409712/
https://www.ncbi.nlm.nih.gov/pubmed/22876357
http://dx.doi.org/10.1364/BOE.3.001947
_version_ 1782239626369433600
author Tan, K. M.
Shishkov, M.
Chee, A.
Applegate, M. B.
Bouma, B. E.
Suter, M. J.
author_facet Tan, K. M.
Shishkov, M.
Chee, A.
Applegate, M. B.
Bouma, B. E.
Suter, M. J.
author_sort Tan, K. M.
collection PubMed
description Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) catheter that functions as a “smart needle” to confirm the needle placement within the target lesion prior to biopsy. The TB-OFDI smart needle consists of a flexible and removable OFDI catheter (430 µm dia.) that operates within a standard 21-gauge TBNA needle. The OFDI imaging core is based on an angle polished ball lens design with a working distance of 160 µm from the catheter sheath and a spot size of 25 µm. To demonstrate the potential of the TB-OFDI smart needle for transbronchial imaging, an inflated excised swine lung was imaged through a standard bronchoscope. Cross-sectional and longitudinal OFDI results reveal the detailed network of alveoli in the lung parenchyma suggesting that the TB-OFDI smart needle may be a useful tool for guiding biopsy acquisition to increase the diagnostic yield.
format Online
Article
Text
id pubmed-3409712
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-34097122012-08-08 Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance Tan, K. M. Shishkov, M. Chee, A. Applegate, M. B. Bouma, B. E. Suter, M. J. Biomed Opt Express Endoscopes, Catheters and Micro-Optics Transbronchial needle aspiration (TBNA) is a procedure routinely performed to diagnose peripheral pulmonary lesions. However, TBNA is associated with a low diagnostic yield due to inappropriate needle placement. We have developed a flexible transbronchial optical frequency domain imaging (TB-OFDI) catheter that functions as a “smart needle” to confirm the needle placement within the target lesion prior to biopsy. The TB-OFDI smart needle consists of a flexible and removable OFDI catheter (430 µm dia.) that operates within a standard 21-gauge TBNA needle. The OFDI imaging core is based on an angle polished ball lens design with a working distance of 160 µm from the catheter sheath and a spot size of 25 µm. To demonstrate the potential of the TB-OFDI smart needle for transbronchial imaging, an inflated excised swine lung was imaged through a standard bronchoscope. Cross-sectional and longitudinal OFDI results reveal the detailed network of alveoli in the lung parenchyma suggesting that the TB-OFDI smart needle may be a useful tool for guiding biopsy acquisition to increase the diagnostic yield. Optical Society of America 2012-07-27 /pmc/articles/PMC3409712/ /pubmed/22876357 http://dx.doi.org/10.1364/BOE.3.001947 Text en ©2012 Optical Society of America http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-No Derivative Works 3.0 Unported License, which permits download and redistribution, provided that the original work is properly cited. This license restricts the article from being modified or used commercially.
spellingShingle Endoscopes, Catheters and Micro-Optics
Tan, K. M.
Shishkov, M.
Chee, A.
Applegate, M. B.
Bouma, B. E.
Suter, M. J.
Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
title Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
title_full Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
title_fullStr Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
title_full_unstemmed Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
title_short Flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
title_sort flexible transbronchial optical frequency domain imaging smart needle for biopsy guidance
topic Endoscopes, Catheters and Micro-Optics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3409712/
https://www.ncbi.nlm.nih.gov/pubmed/22876357
http://dx.doi.org/10.1364/BOE.3.001947
work_keys_str_mv AT tankm flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance
AT shishkovm flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance
AT cheea flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance
AT applegatemb flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance
AT boumabe flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance
AT sutermj flexibletransbronchialopticalfrequencydomainimagingsmartneedleforbiopsyguidance