Cargando…
Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion
Purpose. To evaluate macular thickness, agreement, and intraclass repeatability in three optical coherence tomography (OCT) devices: the time domain (TD) Stratus OCT and two spectral domain (SD) OCTs, Spectralis and Cirrus SD-OCT, in eyes with macular edema secondary to diabetic retinopathy (DR) and...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3410350/ https://www.ncbi.nlm.nih.gov/pubmed/22888403 http://dx.doi.org/10.1155/2012/354783 |
_version_ | 1782239724886294528 |
---|---|
author | Hatef, Elham Khwaja, Afsheen Rentiya, Zubir Ibrahim, Mohamed Shulman, Matthew Turkcuoglu, Peykan Sepah, Yasir Wang, Jianmin Channa, Roomasa Bittencourt, Millena Akhtar, Abeer Heo, Jangwon Do, Diana V. Nguyen, Quan Dong |
author_facet | Hatef, Elham Khwaja, Afsheen Rentiya, Zubir Ibrahim, Mohamed Shulman, Matthew Turkcuoglu, Peykan Sepah, Yasir Wang, Jianmin Channa, Roomasa Bittencourt, Millena Akhtar, Abeer Heo, Jangwon Do, Diana V. Nguyen, Quan Dong |
author_sort | Hatef, Elham |
collection | PubMed |
description | Purpose. To evaluate macular thickness, agreement, and intraclass repeatability in three optical coherence tomography (OCT) devices: the time domain (TD) Stratus OCT and two spectral domain (SD) OCTs, Spectralis and Cirrus SD-OCT, in eyes with macular edema secondary to diabetic retinopathy (DR) and retinal vein occlusion (VO). Methods. In a prospective observational study at a university-based retina practice, retinal thickness tomography was performed simultaneously for fifty-eight patients (91 eyes) with DR and VO employing a time domain and two spectral domain OCTs. Agreement in macular measurements was assessed by constructing Bland-Altman plots. Intraclass repeatability was assessed by intraclass correlation coefficients (ICCs). Results. Based on the Bland-Altman plots for central macular thickness, there was low agreement between the measurements of Cirrus SD-OCT and Stratus OCT, Spectralis OCT and Stratus OCT, as well as Spectralis OCT and Cirrus SD-OCT among DR and RVO patients. All three devices demonstrated high intraclass repeatability, with ICC of 98% for Stratus OCT, 97% for Cirrus SD-OCT, and 100% for Spectralis OCT among DR patients. The ICC was 97% for Stratus OCT, 79% for Cirrus SD-OCT, and 91% for Spectralis OCT among RVO patients. Conclusion. There are low agreements among interdevice measurements. However, intraclass repeatability is high in both TD and SD-OCT devices. |
format | Online Article Text |
id | pubmed-3410350 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-34103502012-08-10 Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion Hatef, Elham Khwaja, Afsheen Rentiya, Zubir Ibrahim, Mohamed Shulman, Matthew Turkcuoglu, Peykan Sepah, Yasir Wang, Jianmin Channa, Roomasa Bittencourt, Millena Akhtar, Abeer Heo, Jangwon Do, Diana V. Nguyen, Quan Dong J Ophthalmol Research Article Purpose. To evaluate macular thickness, agreement, and intraclass repeatability in three optical coherence tomography (OCT) devices: the time domain (TD) Stratus OCT and two spectral domain (SD) OCTs, Spectralis and Cirrus SD-OCT, in eyes with macular edema secondary to diabetic retinopathy (DR) and retinal vein occlusion (VO). Methods. In a prospective observational study at a university-based retina practice, retinal thickness tomography was performed simultaneously for fifty-eight patients (91 eyes) with DR and VO employing a time domain and two spectral domain OCTs. Agreement in macular measurements was assessed by constructing Bland-Altman plots. Intraclass repeatability was assessed by intraclass correlation coefficients (ICCs). Results. Based on the Bland-Altman plots for central macular thickness, there was low agreement between the measurements of Cirrus SD-OCT and Stratus OCT, Spectralis OCT and Stratus OCT, as well as Spectralis OCT and Cirrus SD-OCT among DR and RVO patients. All three devices demonstrated high intraclass repeatability, with ICC of 98% for Stratus OCT, 97% for Cirrus SD-OCT, and 100% for Spectralis OCT among DR patients. The ICC was 97% for Stratus OCT, 79% for Cirrus SD-OCT, and 91% for Spectralis OCT among RVO patients. Conclusion. There are low agreements among interdevice measurements. However, intraclass repeatability is high in both TD and SD-OCT devices. Hindawi Publishing Corporation 2012 2012-07-25 /pmc/articles/PMC3410350/ /pubmed/22888403 http://dx.doi.org/10.1155/2012/354783 Text en Copyright © 2012 Elham Hatef et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Hatef, Elham Khwaja, Afsheen Rentiya, Zubir Ibrahim, Mohamed Shulman, Matthew Turkcuoglu, Peykan Sepah, Yasir Wang, Jianmin Channa, Roomasa Bittencourt, Millena Akhtar, Abeer Heo, Jangwon Do, Diana V. Nguyen, Quan Dong Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion |
title | Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion |
title_full | Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion |
title_fullStr | Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion |
title_full_unstemmed | Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion |
title_short | Comparison of Time Domain and Spectral Domain Optical Coherence Tomography in Measurement of Macular Thickness in Macular Edema Secondary to Diabetic Retinopathy and Retinal Vein Occlusion |
title_sort | comparison of time domain and spectral domain optical coherence tomography in measurement of macular thickness in macular edema secondary to diabetic retinopathy and retinal vein occlusion |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3410350/ https://www.ncbi.nlm.nih.gov/pubmed/22888403 http://dx.doi.org/10.1155/2012/354783 |
work_keys_str_mv | AT hatefelham comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT khwajaafsheen comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT rentiyazubir comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT ibrahimmohamed comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT shulmanmatthew comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT turkcuoglupeykan comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT sepahyasir comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT wangjianmin comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT channaroomasa comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT bittencourtmillena comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT akhtarabeer comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT heojangwon comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT dodianav comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion AT nguyenquandong comparisonoftimedomainandspectraldomainopticalcoherencetomographyinmeasurementofmacularthicknessinmacularedemasecondarytodiabeticretinopathyandretinalveinocclusion |