Cargando…
Treating Stiffness After Total Knee Arthroplasty: A Technical Note and Preliminary Results
Total Knee Replacement is used to treat pain, stiffness and reduced range of movement. It has been estimated that a minimum of 90 degrees of range of motion in the knee is required for normal activities of daily living. In this article we demonstrate a technical note with a small patient series abou...
Autores principales: | Jaiswal, Parag K, Perera, Jonathan R, Khan, Wasim, Rao, Sudhir G |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bentham Open
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3414723/ https://www.ncbi.nlm.nih.gov/pubmed/22888378 http://dx.doi.org/10.2174/1874325001206010276 |
Ejemplares similares
-
Results of total knee arthroplasty for painless, stiff knees
por: Choi, Young-Joon, et al.
Publicado: (2020) -
Stiffness in total knee arthroplasty
por: Schiavone Panni, Alfredo, et al.
Publicado: (2009) -
The stiff total knee arthroplasty: causes, treatment modalities and results
por: Rodríguez-Merchán, E. Carlos
Publicado: (2019) -
The trivector approach for minimally invasive total knee arthroplasty: A technical note
por: Benazzo, Francesco, et al.
Publicado: (2012) -
Total Knee Arthroplasty in Patients with Ipsilateral Fused Hip: A Technical Note
por: Goodman, Stuart B., et al.
Publicado: (2014)