Cargando…

Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces

Walking on irregular terrain influences gait of diabetic patients. We investigate the test-retest reliability and construct validity of gait measured with the DynaPort MiniMod under single and dual task conditions in diabetic patients walking on irregular terrain to identify the measurement error (p...

Descripción completa

Detalles Bibliográficos
Autores principales: de Bruin, Eling D., Hubli, Michèle, Hofer, Pamela, Wolf, Peter, Murer, Kurt, Zijlstra, Wiebren
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3415100/
https://www.ncbi.nlm.nih.gov/pubmed/22900182
http://dx.doi.org/10.1155/2012/954378
_version_ 1782240318022746112
author de Bruin, Eling D.
Hubli, Michèle
Hofer, Pamela
Wolf, Peter
Murer, Kurt
Zijlstra, Wiebren
author_facet de Bruin, Eling D.
Hubli, Michèle
Hofer, Pamela
Wolf, Peter
Murer, Kurt
Zijlstra, Wiebren
author_sort de Bruin, Eling D.
collection PubMed
description Walking on irregular terrain influences gait of diabetic patients. We investigate the test-retest reliability and construct validity of gait measured with the DynaPort MiniMod under single and dual task conditions in diabetic patients walking on irregular terrain to identify the measurement error (precision) and minimal clinical detectable change. 29 patients with Type 2 diabetes were measured once, and 25 repeated the measurement within 7 days. Patients walked on a therapy garden walkway. Differences between three groups of diabetics with various levels of lower extremity neuropathy were analyzed with planned contrasts. ICC was excellent for intervisit measurements with ICC's >0.824. Bland and Altman Plots, SEM, and SDD showed precise values, distributed around zero for both test conditions. A significant effect of grouping on step length performance hints at possible construct validity of the device. Good reliability of DynaPort MiniMod measurements on a therapy garden walkway and an indication for discriminatory capability suggests that DynaPort MiniMod could facilitate the study of gait in diabetic patients in conditions close to real-life situations. Good reliability, small measurement error, and values of minimal clinical detectable change recommend the further utilization of DynaPort MiniMod for the evaluation of gait parameters in diabetic patients.
format Online
Article
Text
id pubmed-3415100
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-34151002012-08-16 Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces de Bruin, Eling D. Hubli, Michèle Hofer, Pamela Wolf, Peter Murer, Kurt Zijlstra, Wiebren J Aging Res Research Article Walking on irregular terrain influences gait of diabetic patients. We investigate the test-retest reliability and construct validity of gait measured with the DynaPort MiniMod under single and dual task conditions in diabetic patients walking on irregular terrain to identify the measurement error (precision) and minimal clinical detectable change. 29 patients with Type 2 diabetes were measured once, and 25 repeated the measurement within 7 days. Patients walked on a therapy garden walkway. Differences between three groups of diabetics with various levels of lower extremity neuropathy were analyzed with planned contrasts. ICC was excellent for intervisit measurements with ICC's >0.824. Bland and Altman Plots, SEM, and SDD showed precise values, distributed around zero for both test conditions. A significant effect of grouping on step length performance hints at possible construct validity of the device. Good reliability of DynaPort MiniMod measurements on a therapy garden walkway and an indication for discriminatory capability suggests that DynaPort MiniMod could facilitate the study of gait in diabetic patients in conditions close to real-life situations. Good reliability, small measurement error, and values of minimal clinical detectable change recommend the further utilization of DynaPort MiniMod for the evaluation of gait parameters in diabetic patients. Hindawi Publishing Corporation 2012 2012-07-31 /pmc/articles/PMC3415100/ /pubmed/22900182 http://dx.doi.org/10.1155/2012/954378 Text en Copyright © 2012 Eling D. de Bruin et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
de Bruin, Eling D.
Hubli, Michèle
Hofer, Pamela
Wolf, Peter
Murer, Kurt
Zijlstra, Wiebren
Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces
title Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces
title_full Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces
title_fullStr Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces
title_full_unstemmed Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces
title_short Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces
title_sort validity and reliability of accelerometer-based gait assessment in patients with diabetes on challenging surfaces
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3415100/
https://www.ncbi.nlm.nih.gov/pubmed/22900182
http://dx.doi.org/10.1155/2012/954378
work_keys_str_mv AT debruinelingd validityandreliabilityofaccelerometerbasedgaitassessmentinpatientswithdiabetesonchallengingsurfaces
AT hublimichele validityandreliabilityofaccelerometerbasedgaitassessmentinpatientswithdiabetesonchallengingsurfaces
AT hoferpamela validityandreliabilityofaccelerometerbasedgaitassessmentinpatientswithdiabetesonchallengingsurfaces
AT wolfpeter validityandreliabilityofaccelerometerbasedgaitassessmentinpatientswithdiabetesonchallengingsurfaces
AT murerkurt validityandreliabilityofaccelerometerbasedgaitassessmentinpatientswithdiabetesonchallengingsurfaces
AT zijlstrawiebren validityandreliabilityofaccelerometerbasedgaitassessmentinpatientswithdiabetesonchallengingsurfaces