Cargando…

Epi-aortic Doppler measurement of cardiac output in univentricular connection

BACKGROUND: In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of e...

Descripción completa

Detalles Bibliográficos
Autores principales: Bogers, Ad J J C, van den Burg, Martin, Schepp, Ronald, Klein, Jan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2009
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3417853/
https://www.ncbi.nlm.nih.gov/pubmed/22915911
_version_ 1782240548212441088
author Bogers, Ad J J C
van den Burg, Martin
Schepp, Ronald
Klein, Jan
author_facet Bogers, Ad J J C
van den Burg, Martin
Schepp, Ronald
Klein, Jan
author_sort Bogers, Ad J J C
collection PubMed
description BACKGROUND: In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of epi-aortic Doppler measurements in order to calculate cardiac output. METHODS: : Epi-aortic cardiac output measurement was compared with Fick measurements as the gold standard in eight patients with a univentricular circulation after a Fontan-type operation. RESULTS: The mean diameter of the aorta by epi-aortic measurement was 18 mm (range 14 to 25), by angiography 17 mm (range 10 to 24), correlation coefficient 0.88 (p < 0.05). The mean cardiac output by epi-aortic measurement was 2.8 l.min(−1) (range 1.2 to 6.3), by the Fick calculations 1.8 l.min(−1) (range 0.8 to 5.0). The correlation coefficient for cardiac output data in aortic diameters up to 20 millimeter in diameter was 0.55 (p < 0.05). CONCLUSIONS: Epi-aortic Doppler measurement of cardiac output after Fontan type reconstructions could be applied in aortas up to 20 millimeter in diameter. A reasonable correlation with Fick calculations was found. This was supported by Bland–Altman plotting. The method is intrinsically invasive, but application and removal of the device were easy and no complications related to the system were observed. An important restriction is the often present abnormal anatomy, either congenitally or after surgery.
format Online
Article
Text
id pubmed-3417853
institution National Center for Biotechnology Information
language English
publishDate 2009
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-34178532012-08-22 Epi-aortic Doppler measurement of cardiac output in univentricular connection Bogers, Ad J J C van den Burg, Martin Schepp, Ronald Klein, Jan Med Devices (Auckl) Original Research BACKGROUND: In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of epi-aortic Doppler measurements in order to calculate cardiac output. METHODS: : Epi-aortic cardiac output measurement was compared with Fick measurements as the gold standard in eight patients with a univentricular circulation after a Fontan-type operation. RESULTS: The mean diameter of the aorta by epi-aortic measurement was 18 mm (range 14 to 25), by angiography 17 mm (range 10 to 24), correlation coefficient 0.88 (p < 0.05). The mean cardiac output by epi-aortic measurement was 2.8 l.min(−1) (range 1.2 to 6.3), by the Fick calculations 1.8 l.min(−1) (range 0.8 to 5.0). The correlation coefficient for cardiac output data in aortic diameters up to 20 millimeter in diameter was 0.55 (p < 0.05). CONCLUSIONS: Epi-aortic Doppler measurement of cardiac output after Fontan type reconstructions could be applied in aortas up to 20 millimeter in diameter. A reasonable correlation with Fick calculations was found. This was supported by Bland–Altman plotting. The method is intrinsically invasive, but application and removal of the device were easy and no complications related to the system were observed. An important restriction is the often present abnormal anatomy, either congenitally or after surgery. Dove Medical Press 2009-02-03 /pmc/articles/PMC3417853/ /pubmed/22915911 Text en © 2009 Bogers et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Bogers, Ad J J C
van den Burg, Martin
Schepp, Ronald
Klein, Jan
Epi-aortic Doppler measurement of cardiac output in univentricular connection
title Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_full Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_fullStr Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_full_unstemmed Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_short Epi-aortic Doppler measurement of cardiac output in univentricular connection
title_sort epi-aortic doppler measurement of cardiac output in univentricular connection
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3417853/
https://www.ncbi.nlm.nih.gov/pubmed/22915911
work_keys_str_mv AT bogersadjjc epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
AT vandenburgmartin epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
AT scheppronald epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection
AT kleinjan epiaorticdopplermeasurementofcardiacoutputinuniventricularconnection