Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block
BACKGROUND: Stellate ganglion block (SGB) is a widely used procedure for treatment of pain in the head and upper body, but the clinical signs used to verify the effectiveness of SGB can be ambiguous or variable in some patients. We observed the chronological changes in perfusion index (PI) from puls...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3417976/ https://www.ncbi.nlm.nih.gov/pubmed/22915896 http://dx.doi.org/10.2147/LRA.S30257 |
_version_ | 1782240574911283200 |
---|---|
author | Yamazaki, Hajime Nishiyama, Junichi Suzuki, Toshiyasu |
author_facet | Yamazaki, Hajime Nishiyama, Junichi Suzuki, Toshiyasu |
author_sort | Yamazaki, Hajime |
collection | PubMed |
description | BACKGROUND: Stellate ganglion block (SGB) is a widely used procedure for treatment of pain in the head and upper body, but the clinical signs used to verify the effectiveness of SGB can be ambiguous or variable in some patients. We observed the chronological changes in perfusion index (PI) from pulse oximetry to determine if these changes correlated with the clinical signs associated with an effective SGB. We hypothesized that PI could provide an easy method to assess the effectiveness of SGB. METHOD: We compared the chronologies in PI on the treated and untreated sides of 21 patients in whom treatment by SGB was found to be effective. The SGB was performed by administering 6 mL of 1% mepivacaine. The effectiveness of the SGB was confirmed on the basis of clinical signs. Additionally, in two patients we tested whether increased PI on the treatment side correlated with increased microcirculation as measured by laser-Doppler blood flowmetry. RESULTS: On the side treated by SGB, PI increased 61.4% in the earlobe and 60.5% from baseline values in the upper limbs, at 5 minutes after initiation of the procedure. Differences in PI before and after treatment were significant at both sites. No time-course increases in PI were found on the untreated side at either site. Following SGB, increases in PI correlated with increases in blood flow as measured by laser-Doppler flowmetry. CONCLUSION: PI increased in the earlobe and upper limbs on the treated side of 21 patients who received an effective SGB but not on the untreated side. The positive correlations between changes in PI and both presence of clinical signs and changes in blood flow in the skin microcirculation indicate a sympatholytic effect, suggesting that the PI could be useful in determination of the efficacy of SGB. |
format | Online Article Text |
id | pubmed-3417976 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34179762012-08-22 Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block Yamazaki, Hajime Nishiyama, Junichi Suzuki, Toshiyasu Local Reg Anesth Original Research BACKGROUND: Stellate ganglion block (SGB) is a widely used procedure for treatment of pain in the head and upper body, but the clinical signs used to verify the effectiveness of SGB can be ambiguous or variable in some patients. We observed the chronological changes in perfusion index (PI) from pulse oximetry to determine if these changes correlated with the clinical signs associated with an effective SGB. We hypothesized that PI could provide an easy method to assess the effectiveness of SGB. METHOD: We compared the chronologies in PI on the treated and untreated sides of 21 patients in whom treatment by SGB was found to be effective. The SGB was performed by administering 6 mL of 1% mepivacaine. The effectiveness of the SGB was confirmed on the basis of clinical signs. Additionally, in two patients we tested whether increased PI on the treatment side correlated with increased microcirculation as measured by laser-Doppler blood flowmetry. RESULTS: On the side treated by SGB, PI increased 61.4% in the earlobe and 60.5% from baseline values in the upper limbs, at 5 minutes after initiation of the procedure. Differences in PI before and after treatment were significant at both sites. No time-course increases in PI were found on the untreated side at either site. Following SGB, increases in PI correlated with increases in blood flow as measured by laser-Doppler flowmetry. CONCLUSION: PI increased in the earlobe and upper limbs on the treated side of 21 patients who received an effective SGB but not on the untreated side. The positive correlations between changes in PI and both presence of clinical signs and changes in blood flow in the skin microcirculation indicate a sympatholytic effect, suggesting that the PI could be useful in determination of the efficacy of SGB. Dove Medical Press 2012-03-13 /pmc/articles/PMC3417976/ /pubmed/22915896 http://dx.doi.org/10.2147/LRA.S30257 Text en © 2012 Yamazaki et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Yamazaki, Hajime Nishiyama, Junichi Suzuki, Toshiyasu Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
title | Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
title_full | Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
title_fullStr | Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
title_full_unstemmed | Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
title_short | Use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
title_sort | use of perfusion index from pulse oximetry to determine efficacy of stellate ganglion block |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3417976/ https://www.ncbi.nlm.nih.gov/pubmed/22915896 http://dx.doi.org/10.2147/LRA.S30257 |
work_keys_str_mv | AT yamazakihajime useofperfusionindexfrompulseoximetrytodetermineefficacyofstellateganglionblock AT nishiyamajunichi useofperfusionindexfrompulseoximetrytodetermineefficacyofstellateganglionblock AT suzukitoshiyasu useofperfusionindexfrompulseoximetrytodetermineefficacyofstellateganglionblock |