Cargando…
Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry
A sensitive and reliable method of liquid chromatography–electrospray ionization/tandem mass spectrometry (LC-ESI/MS/ MS) was developed and validated for determining 1,3-dimethylamylamine (1,3-DMAA) and 1,4-dimethylamylamine (1,4-DMAA) in geranium plants (Pelargonium graveolens). The sample was extr...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Libertas Academica
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3422085/ https://www.ncbi.nlm.nih.gov/pubmed/22915838 http://dx.doi.org/10.4137/ACI.S9969 |
_version_ | 1782240987176763392 |
---|---|
author | Li, J.S. Chen, M. Li, Z.C. |
author_facet | Li, J.S. Chen, M. Li, Z.C. |
author_sort | Li, J.S. |
collection | PubMed |
description | A sensitive and reliable method of liquid chromatography–electrospray ionization/tandem mass spectrometry (LC-ESI/MS/ MS) was developed and validated for determining 1,3-dimethylamylamine (1,3-DMAA) and 1,4-dimethylamylamine (1,4-DMAA) in geranium plants (Pelargonium graveolens). The sample was extracted with 0.5 M HCl and purified by liquid-liquid partition with hexane. The parameters for reverse-phase (C18) LC and positive ESI/MS/MS were optimized. The matrix effect, specificity, linearity, precision, accuracy and reproducibility of the method were determined and evaluated. The method was linear over a range of 0.10–10.00 ng/mL examined, with R(2) of 0.99 for both 1,3-DMAA and 1,4-DMAA. The recoveries from spiked concentrations between 5.00–40.00 ng/g were 85.1%–104.9% for 1,3-DMAA, with relative standard deviation (RSD) of 2.9%–11.0%, and 82.9%–101.8% for 1,4-DMAA, with RSD of 3.2%–11.7%. The instrument detection limit was 1–2 pg for both DMAAs. The quantification limit was estimated to be 1–2 ng/g for the plant sample. This method was successfully applied to the quantitative determination of 1,3- and 1,4-DMAA in both geranium plant and geranium oil. |
format | Online Article Text |
id | pubmed-3422085 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Libertas Academica |
record_format | MEDLINE/PubMed |
spelling | pubmed-34220852012-08-22 Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry Li, J.S. Chen, M. Li, Z.C. Anal Chem Insights Rapid Communication A sensitive and reliable method of liquid chromatography–electrospray ionization/tandem mass spectrometry (LC-ESI/MS/ MS) was developed and validated for determining 1,3-dimethylamylamine (1,3-DMAA) and 1,4-dimethylamylamine (1,4-DMAA) in geranium plants (Pelargonium graveolens). The sample was extracted with 0.5 M HCl and purified by liquid-liquid partition with hexane. The parameters for reverse-phase (C18) LC and positive ESI/MS/MS were optimized. The matrix effect, specificity, linearity, precision, accuracy and reproducibility of the method were determined and evaluated. The method was linear over a range of 0.10–10.00 ng/mL examined, with R(2) of 0.99 for both 1,3-DMAA and 1,4-DMAA. The recoveries from spiked concentrations between 5.00–40.00 ng/g were 85.1%–104.9% for 1,3-DMAA, with relative standard deviation (RSD) of 2.9%–11.0%, and 82.9%–101.8% for 1,4-DMAA, with RSD of 3.2%–11.7%. The instrument detection limit was 1–2 pg for both DMAAs. The quantification limit was estimated to be 1–2 ng/g for the plant sample. This method was successfully applied to the quantitative determination of 1,3- and 1,4-DMAA in both geranium plant and geranium oil. Libertas Academica 2012-08-06 /pmc/articles/PMC3422085/ /pubmed/22915838 http://dx.doi.org/10.4137/ACI.S9969 Text en © the author(s), publisher and licensee Libertas Academica Ltd. This is an open access article. Unrestricted non-commercial use is permitted provided the original work is properly cited. |
spellingShingle | Rapid Communication Li, J.S. Chen, M. Li, Z.C. Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry |
title | Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry |
title_full | Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry |
title_fullStr | Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry |
title_full_unstemmed | Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry |
title_short | Identification and Quantification of Dimethylamylamine in Geranium by Liquid Chromatography Tandem Mass Spectrometry |
title_sort | identification and quantification of dimethylamylamine in geranium by liquid chromatography tandem mass spectrometry |
topic | Rapid Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3422085/ https://www.ncbi.nlm.nih.gov/pubmed/22915838 http://dx.doi.org/10.4137/ACI.S9969 |
work_keys_str_mv | AT lijs identificationandquantificationofdimethylamylamineingeraniumbyliquidchromatographytandemmassspectrometry AT chenm identificationandquantificationofdimethylamylamineingeraniumbyliquidchromatographytandemmassspectrometry AT lizc identificationandquantificationofdimethylamylamineingeraniumbyliquidchromatographytandemmassspectrometry |