Cargando…

(Mis)placed central venous catheter in the left superior intercostal vein

BACKGROUND: Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruc...

Descripción completa

Detalles Bibliográficos
Autores principales: Padovan, Ranka Stern, Paar, Maja Hrabak, Aurer, Igor
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Versita, Warsaw 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3423719/
https://www.ncbi.nlm.nih.gov/pubmed/22933931
http://dx.doi.org/10.2478/v10019-010-0043-7
_version_ 1782241136254910464
author Padovan, Ranka Stern
Paar, Maja Hrabak
Aurer, Igor
author_facet Padovan, Ranka Stern
Paar, Maja Hrabak
Aurer, Igor
author_sort Padovan, Ranka Stern
collection PubMed
description BACKGROUND: Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. CASE REPORT. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. CONCLUSIONS: Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity.
format Online
Article
Text
id pubmed-3423719
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Versita, Warsaw
record_format MEDLINE/PubMed
spelling pubmed-34237192012-08-29 (Mis)placed central venous catheter in the left superior intercostal vein Padovan, Ranka Stern Paar, Maja Hrabak Aurer, Igor Radiol Oncol Case Report BACKGROUND: Chest X-ray is routinely performed to check the position of the central venous catheter (CVC) inserted through the internal jugular or subclavian vein, while the further evaluation of CVC malfunction is usually performed by contrast venography. In patients with superior vena cava obstruction, the tip of the catheter is often seen in collateral mediastinal venous pathways, rather than in the superior vena cava. In such cases detailed knowledge of thoracic vessel anatomy is necessary to identify the exact location of the catheter. CASE REPORT. We report a case of 32-year-old female patient with relapsing mediastinal lymphoma and previous superior vena cava obstruction with collateral azygos-hemiazygos venous pathways. The patient had CVC inserted through the left subclavian vein and its position was detected by CT to be in the dilated left superior intercostal vein and accessory hemiazygos vein. Considering that dilated accessory hemiazygos vein can tolerate infusion, the CVC was left in place and the patient had no complaints related to CVC (mal)position. Furthermore, we present anatomical and radiological observations on the azygos-hemiazygos venous system with the special emphasis on the left superior intercostal vein. CONCLUSIONS: Non-contrast CT scans can be a valuable imaging tool in the detection of the CVC position, especially in patients with renal insufficiency and contrast media hypersensitivity. Versita, Warsaw 2010-09-29 /pmc/articles/PMC3423719/ /pubmed/22933931 http://dx.doi.org/10.2478/v10019-010-0043-7 Text en Copyright © by Association of Radiology & Oncology http://creativecommons.org/licenses/by/3.0 This article is an open-access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Case Report
Padovan, Ranka Stern
Paar, Maja Hrabak
Aurer, Igor
(Mis)placed central venous catheter in the left superior intercostal vein
title (Mis)placed central venous catheter in the left superior intercostal vein
title_full (Mis)placed central venous catheter in the left superior intercostal vein
title_fullStr (Mis)placed central venous catheter in the left superior intercostal vein
title_full_unstemmed (Mis)placed central venous catheter in the left superior intercostal vein
title_short (Mis)placed central venous catheter in the left superior intercostal vein
title_sort (mis)placed central venous catheter in the left superior intercostal vein
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3423719/
https://www.ncbi.nlm.nih.gov/pubmed/22933931
http://dx.doi.org/10.2478/v10019-010-0043-7
work_keys_str_mv AT padovanrankastern misplacedcentralvenouscatheterintheleftsuperiorintercostalvein
AT paarmajahrabak misplacedcentralvenouscatheterintheleftsuperiorintercostalvein
AT aurerigor misplacedcentralvenouscatheterintheleftsuperiorintercostalvein