Cargando…
Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system
BACKGROUND: Closed loop anaesthesia delivery systems (CLADSs) are a recent advancement in accurate titration of anaesthetic drugs. They have been shown to be superior in maintaining adequate depth of anaesthesia with few fluctuations as compared with target-controlled infusion or manual titration of...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3425282/ https://www.ncbi.nlm.nih.gov/pubmed/22923821 http://dx.doi.org/10.4103/0019-5049.98765 |
_version_ | 1782241355876007936 |
---|---|
author | Puri, Goverdhan D Jayant, Aveek Tsering, Morup Dorje, Motup Tashi, Motup |
author_facet | Puri, Goverdhan D Jayant, Aveek Tsering, Morup Dorje, Motup Tashi, Motup |
author_sort | Puri, Goverdhan D |
collection | PubMed |
description | BACKGROUND: Closed loop anaesthesia delivery systems (CLADSs) are a recent advancement in accurate titration of anaesthetic drugs. They have been shown to be superior in maintaining adequate depth of anaesthesia with few fluctuations as compared with target-controlled infusion or manual titration of drug delivery. METHODS: Twenty patients scheduled to undergo general abdominal or orthopaedic procedures under general anaesthesia at Leh (3505 m above sea level) were recruited as subjects. Anaesthesia was delivered by a patented closed loop system that uses the Bispectral Index (BIS™) as a feedback parameter to titrate the rate of propofol infusion. All vital parameters, drug infusion rate and the BIS™ values were continuously recorded and stored online by the system. The data generated was analysed for the adequacy of anaesthetic depth, haemodynamic stability and post-operative recovery parameters. RESULTS: The CLADS was able to maintain a BIS™ within ±10 of the target of 50 for 85.0±7.8% of the time. Haemodynamics were appropriately maintained (heart rate and mean arterial blood pressure were within 25% of baseline values for 91.2±2.2% and 94.1±3% of the total anaesthesia time, respectively). Subjects were awake within a median of 3 min from cessation of drug infusion and achieved fitness to recovery room discharge within a median of 15 min. There were no adverse events or report of awareness under anaesthesia. CONCLUSIONS: The study demonstrates the safety of our CLADS at high altitude. It seeks to extend the use of our system in challenging anaesthesia environments. The system performance was also adequate and no adverse events were recorded. |
format | Online Article Text |
id | pubmed-3425282 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-34252822012-08-24 Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system Puri, Goverdhan D Jayant, Aveek Tsering, Morup Dorje, Motup Tashi, Motup Indian J Anaesth Clinical Investigation BACKGROUND: Closed loop anaesthesia delivery systems (CLADSs) are a recent advancement in accurate titration of anaesthetic drugs. They have been shown to be superior in maintaining adequate depth of anaesthesia with few fluctuations as compared with target-controlled infusion or manual titration of drug delivery. METHODS: Twenty patients scheduled to undergo general abdominal or orthopaedic procedures under general anaesthesia at Leh (3505 m above sea level) were recruited as subjects. Anaesthesia was delivered by a patented closed loop system that uses the Bispectral Index (BIS™) as a feedback parameter to titrate the rate of propofol infusion. All vital parameters, drug infusion rate and the BIS™ values were continuously recorded and stored online by the system. The data generated was analysed for the adequacy of anaesthetic depth, haemodynamic stability and post-operative recovery parameters. RESULTS: The CLADS was able to maintain a BIS™ within ±10 of the target of 50 for 85.0±7.8% of the time. Haemodynamics were appropriately maintained (heart rate and mean arterial blood pressure were within 25% of baseline values for 91.2±2.2% and 94.1±3% of the total anaesthesia time, respectively). Subjects were awake within a median of 3 min from cessation of drug infusion and achieved fitness to recovery room discharge within a median of 15 min. There were no adverse events or report of awareness under anaesthesia. CONCLUSIONS: The study demonstrates the safety of our CLADS at high altitude. It seeks to extend the use of our system in challenging anaesthesia environments. The system performance was also adequate and no adverse events were recorded. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3425282/ /pubmed/22923821 http://dx.doi.org/10.4103/0019-5049.98765 Text en Copyright: © Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Clinical Investigation Puri, Goverdhan D Jayant, Aveek Tsering, Morup Dorje, Motup Tashi, Motup Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
title | Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
title_full | Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
title_fullStr | Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
title_full_unstemmed | Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
title_short | Closed loop anaesthesia at high altitude (3505 m above sea level): Performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
title_sort | closed loop anaesthesia at high altitude (3505 m above sea level): performance characteristics of an indigenously developed closed loop anaesthesia delivery system |
topic | Clinical Investigation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3425282/ https://www.ncbi.nlm.nih.gov/pubmed/22923821 http://dx.doi.org/10.4103/0019-5049.98765 |
work_keys_str_mv | AT purigoverdhand closedloopanaesthesiaathighaltitude3505mabovesealevelperformancecharacteristicsofanindigenouslydevelopedclosedloopanaesthesiadeliverysystem AT jayantaveek closedloopanaesthesiaathighaltitude3505mabovesealevelperformancecharacteristicsofanindigenouslydevelopedclosedloopanaesthesiadeliverysystem AT tseringmorup closedloopanaesthesiaathighaltitude3505mabovesealevelperformancecharacteristicsofanindigenouslydevelopedclosedloopanaesthesiadeliverysystem AT dorjemotup closedloopanaesthesiaathighaltitude3505mabovesealevelperformancecharacteristicsofanindigenouslydevelopedclosedloopanaesthesiadeliverysystem AT tashimotup closedloopanaesthesiaathighaltitude3505mabovesealevelperformancecharacteristicsofanindigenouslydevelopedclosedloopanaesthesiadeliverysystem |