Cargando…

Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method

Bioluminescence tomography (BLT) is a molecular imaging modality which can three-dimensionally resolve the molecular processes in small animals in vivo. The ill-posedness nature of BLT problem makes its reconstruction bears nonunique solution and is sensitive to noise. In this paper, we proposed a s...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Wei, Jia, Kebin, Zhang, Qian, Liu, Xueyan, Feng, Jinchao, Qin, Chenghu, Ma, Xibo, Yang, Xin, Tian, Jie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3426305/
https://www.ncbi.nlm.nih.gov/pubmed/22927887
http://dx.doi.org/10.1155/2012/494808
_version_ 1782241494450569216
author Guo, Wei
Jia, Kebin
Zhang, Qian
Liu, Xueyan
Feng, Jinchao
Qin, Chenghu
Ma, Xibo
Yang, Xin
Tian, Jie
author_facet Guo, Wei
Jia, Kebin
Zhang, Qian
Liu, Xueyan
Feng, Jinchao
Qin, Chenghu
Ma, Xibo
Yang, Xin
Tian, Jie
author_sort Guo, Wei
collection PubMed
description Bioluminescence tomography (BLT) is a molecular imaging modality which can three-dimensionally resolve the molecular processes in small animals in vivo. The ill-posedness nature of BLT problem makes its reconstruction bears nonunique solution and is sensitive to noise. In this paper, we proposed a sparse BLT reconstruction algorithm based on semigreedy method. To reduce the ill-posedness and computational cost, the optimal permissible source region was automatically chosen by using an iterative search tree. The proposed method obtained fast and stable source reconstruction from the whole body and imposed constraint without using a regularization penalty term. Numerical simulations on a mouse atlas, and in vivo mouse experiments were conducted to validate the effectiveness and potential of the method.
format Online
Article
Text
id pubmed-3426305
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-34263052012-08-27 Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method Guo, Wei Jia, Kebin Zhang, Qian Liu, Xueyan Feng, Jinchao Qin, Chenghu Ma, Xibo Yang, Xin Tian, Jie Comput Math Methods Med Research Article Bioluminescence tomography (BLT) is a molecular imaging modality which can three-dimensionally resolve the molecular processes in small animals in vivo. The ill-posedness nature of BLT problem makes its reconstruction bears nonunique solution and is sensitive to noise. In this paper, we proposed a sparse BLT reconstruction algorithm based on semigreedy method. To reduce the ill-posedness and computational cost, the optimal permissible source region was automatically chosen by using an iterative search tree. The proposed method obtained fast and stable source reconstruction from the whole body and imposed constraint without using a regularization penalty term. Numerical simulations on a mouse atlas, and in vivo mouse experiments were conducted to validate the effectiveness and potential of the method. Hindawi Publishing Corporation 2012 2012-08-14 /pmc/articles/PMC3426305/ /pubmed/22927887 http://dx.doi.org/10.1155/2012/494808 Text en Copyright © 2012 Wei Guo et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Guo, Wei
Jia, Kebin
Zhang, Qian
Liu, Xueyan
Feng, Jinchao
Qin, Chenghu
Ma, Xibo
Yang, Xin
Tian, Jie
Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method
title Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method
title_full Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method
title_fullStr Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method
title_full_unstemmed Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method
title_short Sparse Reconstruction for Bioluminescence Tomography Based on the Semigreedy Method
title_sort sparse reconstruction for bioluminescence tomography based on the semigreedy method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3426305/
https://www.ncbi.nlm.nih.gov/pubmed/22927887
http://dx.doi.org/10.1155/2012/494808
work_keys_str_mv AT guowei sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT jiakebin sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT zhangqian sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT liuxueyan sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT fengjinchao sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT qinchenghu sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT maxibo sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT yangxin sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod
AT tianjie sparsereconstructionforbioluminescencetomographybasedonthesemigreedymethod