Cargando…

Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal

This paper presents a model-based approach to estimation of cardiac output (CO) and total peripheral resistance (TPR). In the proposed approach, the response of cardiovascular system (CVS), described by the windkessel model, is tuned to the measurements of systolic, diastolic and mean arterial blood...

Descripción completa

Detalles Bibliográficos
Autores principales: Fazeli, Nima, Hahn, Jin-Oh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3429069/
https://www.ncbi.nlm.nih.gov/pubmed/22934049
http://dx.doi.org/10.3389/fphys.2012.00298
_version_ 1782241763538239488
author Fazeli, Nima
Hahn, Jin-Oh
author_facet Fazeli, Nima
Hahn, Jin-Oh
author_sort Fazeli, Nima
collection PubMed
description This paper presents a model-based approach to estimation of cardiac output (CO) and total peripheral resistance (TPR). In the proposed approach, the response of cardiovascular system (CVS), described by the windkessel model, is tuned to the measurements of systolic, diastolic and mean arterial blood pressures (BP) so as to yield optimal individual- and time-specific system time constant that is used to estimate CO and TPR. Unique aspects of the proposed approach are that it approximates the aortic flow as a train of square waves and that it also assumes pressure-dependent arterial compliance, as opposed to the traditional windkessel model in which aortic flow is approximated as a train of impulses and constant arterial compliance is assumed. It was shown that the proposed model encompasses the standard windkessel model as a limiting case, and that it also yields more realistic BP waveform response than the standard windkessel model. The proposed approach has potential to outperform its standard counterpart by treating systolic, diastolic, and mean BP as independent features in estimating CO and TPR, rather than solely resorting to pulse pressure as in the case of the standard windkessel model. Experimental results from in-vivo data collected from a number of animal subjects supports the viability of the proposed approach in that it could achieve approximately 29% and 24% reduction in CO and TPR errors when compared with its standard counterpart.
format Online
Article
Text
id pubmed-3429069
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-34290692012-08-29 Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal Fazeli, Nima Hahn, Jin-Oh Front Physiol Physiology This paper presents a model-based approach to estimation of cardiac output (CO) and total peripheral resistance (TPR). In the proposed approach, the response of cardiovascular system (CVS), described by the windkessel model, is tuned to the measurements of systolic, diastolic and mean arterial blood pressures (BP) so as to yield optimal individual- and time-specific system time constant that is used to estimate CO and TPR. Unique aspects of the proposed approach are that it approximates the aortic flow as a train of square waves and that it also assumes pressure-dependent arterial compliance, as opposed to the traditional windkessel model in which aortic flow is approximated as a train of impulses and constant arterial compliance is assumed. It was shown that the proposed model encompasses the standard windkessel model as a limiting case, and that it also yields more realistic BP waveform response than the standard windkessel model. The proposed approach has potential to outperform its standard counterpart by treating systolic, diastolic, and mean BP as independent features in estimating CO and TPR, rather than solely resorting to pulse pressure as in the case of the standard windkessel model. Experimental results from in-vivo data collected from a number of animal subjects supports the viability of the proposed approach in that it could achieve approximately 29% and 24% reduction in CO and TPR errors when compared with its standard counterpart. Frontiers Media S.A. 2012-07-25 /pmc/articles/PMC3429069/ /pubmed/22934049 http://dx.doi.org/10.3389/fphys.2012.00298 Text en Copyright © 2012 Fazeli and Hahn. http://www.frontiersin.org/licenseagreement This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in other forums, provided the original authors and source are credited and subject to any copyright notices concerning any third-party graphics etc.
spellingShingle Physiology
Fazeli, Nima
Hahn, Jin-Oh
Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
title Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
title_full Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
title_fullStr Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
title_full_unstemmed Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
title_short Estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
title_sort estimation of cardiac output and peripheral resistance using square-wave-approximated aortic flow signal
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3429069/
https://www.ncbi.nlm.nih.gov/pubmed/22934049
http://dx.doi.org/10.3389/fphys.2012.00298
work_keys_str_mv AT fazelinima estimationofcardiacoutputandperipheralresistanceusingsquarewaveapproximatedaorticflowsignal
AT hahnjinoh estimationofcardiacoutputandperipheralresistanceusingsquarewaveapproximatedaorticflowsignal