Cargando…

Comparison of dose–volume analysis between standard Manchester plan and magnetic resonance image-based plan of intracavitary brachytherapy for uterine cervical cancer

To investigate the feasibility of image-based intracavitary brachytherapy (IBICBT) for uterine cervical cancer, we evaluated the dose–volume histograms (DVHs) for the tumor and organs at risk (OARs) and compared results from the IBICBT plan and the standard Manchester system (Manchester plan) in eig...

Descripción completa

Detalles Bibliográficos
Autores principales: Takenaka, Tadashi, Yoshida, Ken, Tachiiri, Seiji, Yamazaki,, Hideya, Aramoto, Kazumasa, Furuya, Seiichi, Yoshida, Mineo, Ban, Chiaki, Tanaka, Eiichi, Honda, Kazuya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3430414/
https://www.ncbi.nlm.nih.gov/pubmed/22843369
http://dx.doi.org/10.1093/jrr/rrs033
Descripción
Sumario:To investigate the feasibility of image-based intracavitary brachytherapy (IBICBT) for uterine cervical cancer, we evaluated the dose–volume histograms (DVHs) for the tumor and organs at risk (OARs) and compared results from the IBICBT plan and the standard Manchester system (Manchester plan) in eight patients as a simulation experiment. We performed magnetic resonance imaging (MRI) and computed tomography (CT) following MRI-adapted applicator insertion, then superimposed MR images on the planning CT images to describe the contours of high-risk clinical target volume (HR CTV) and OARs. The median volume of HR CTV was 29 cm(3) (range, 21–61 cm(3)). Median D90 (HR CTV) and V100 (HR CTV) were 116.1% prescribed doses (PD) (90.0–150.8%) and 96.7% (84.2–100%), respectively, for the Manchester plan. In comparison, we confirmed that the median D90 (HR CTV) was 100% PD in the IBICBT plan for all patients. Mean D(2cc) (bladder) was 101.8% PD for the Manchester plan and 83.2% PD for the IBICBT plan. Mean D(2cc) (rectum) was 80.1% PD for the Manchester plan and 64.2% PD for the IBICBT plan. Mean D(2cc) (sigmoid) was 75% PD for the Manchester plan and 57.5% PD for the IBICBT plan. One patient with a large tumor (HR CTV, 61 cm(3)) showed lower D90 (HR CTV) with the Manchester plan than with the IBICBT plan. The Manchester plan may represent overtreatment for small tumors but insufficient dose distribution for larger tumors. The IBICBT plan could reduce OAR dosage while maintaining adequate tumor coverage.