Cargando…
Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer
We compared the efficiency and accuracy of full-arc and half-arc volumetric-modulated arc therapy (VMAT) delivery for maxillary cancer. Plans for gantry rotation angles of 360° and 180° (full-arc and half-arc VMAT) were created for six maxillary cancer cases with the Monaco treatment planning system...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3430421/ https://www.ncbi.nlm.nih.gov/pubmed/22843367 http://dx.doi.org/10.1093/jrr/rrs031 |
_version_ | 1782241939347734528 |
---|---|
author | Miura, Hideharu Fujiwara, Masayuki Tanooka, Masao Doi, Hiroshi Inoue, Hiroyuki Takada, Yasuhiro Kamikonya, Norihiko Hirota, Shozo |
author_facet | Miura, Hideharu Fujiwara, Masayuki Tanooka, Masao Doi, Hiroshi Inoue, Hiroyuki Takada, Yasuhiro Kamikonya, Norihiko Hirota, Shozo |
author_sort | Miura, Hideharu |
collection | PubMed |
description | We compared the efficiency and accuracy of full-arc and half-arc volumetric-modulated arc therapy (VMAT) delivery for maxillary cancer. Plans for gantry rotation angles of 360° and 180° (full-arc and half-arc VMAT) were created for six maxillary cancer cases with the Monaco treatment planning system, and delivered using an Elekta Synergy linear accelerator. Full-arc and half-arc VMAT were compared with regard to homogeneity index (HI), conformity index (CI), mean dose to normal brain, total monitor units (MU), delivery times, root mean square (r.m.s.) gantry accelerations (°/s(2)), and r.m.s. gantry angle errors (°). The half-arc VMAT plans achieved comparable HI and CI to the full-arc plans. Mean doses to the normal brain and brainstem with the half-arc VMAT plans were on average 16% and 17% lower than those with the full-arc VMAT plans. For other organs at risk (OARs), no significant DVH differences were observed between plans. Half-arc VMAT resulted in 11% less total MU and 20% shorter delivery time than the full-arc VMAT, while r.m.s. gantry acceleration and r.m.s. gantry angle error during half-arc VMAT delivery were 30% and 23% less than those during full-arc VMAT delivery, respectively. Furthermore, the half-arc VMAT plans were comparable with the full-arc plans regarding dose homogeneity and conformity in maxillary cancer, and provided a statistical decrease in mean dose to OAR, total MU, delivery time and gantry angle error. Half-arc VMAT plans may be a suitable treatment option in radiotherapy for maxillary cancer. |
format | Online Article Text |
id | pubmed-3430421 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34304212012-08-29 Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer Miura, Hideharu Fujiwara, Masayuki Tanooka, Masao Doi, Hiroshi Inoue, Hiroyuki Takada, Yasuhiro Kamikonya, Norihiko Hirota, Shozo J Radiat Res Technology We compared the efficiency and accuracy of full-arc and half-arc volumetric-modulated arc therapy (VMAT) delivery for maxillary cancer. Plans for gantry rotation angles of 360° and 180° (full-arc and half-arc VMAT) were created for six maxillary cancer cases with the Monaco treatment planning system, and delivered using an Elekta Synergy linear accelerator. Full-arc and half-arc VMAT were compared with regard to homogeneity index (HI), conformity index (CI), mean dose to normal brain, total monitor units (MU), delivery times, root mean square (r.m.s.) gantry accelerations (°/s(2)), and r.m.s. gantry angle errors (°). The half-arc VMAT plans achieved comparable HI and CI to the full-arc plans. Mean doses to the normal brain and brainstem with the half-arc VMAT plans were on average 16% and 17% lower than those with the full-arc VMAT plans. For other organs at risk (OARs), no significant DVH differences were observed between plans. Half-arc VMAT resulted in 11% less total MU and 20% shorter delivery time than the full-arc VMAT, while r.m.s. gantry acceleration and r.m.s. gantry angle error during half-arc VMAT delivery were 30% and 23% less than those during full-arc VMAT delivery, respectively. Furthermore, the half-arc VMAT plans were comparable with the full-arc plans regarding dose homogeneity and conformity in maxillary cancer, and provided a statistical decrease in mean dose to OAR, total MU, delivery time and gantry angle error. Half-arc VMAT plans may be a suitable treatment option in radiotherapy for maxillary cancer. Oxford University Press 2012-09 2012-07-26 /pmc/articles/PMC3430421/ /pubmed/22843367 http://dx.doi.org/10.1093/jrr/rrs031 Text en © The Author 2012. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Therapeutic Radiology and Oncology. http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Technology Miura, Hideharu Fujiwara, Masayuki Tanooka, Masao Doi, Hiroshi Inoue, Hiroyuki Takada, Yasuhiro Kamikonya, Norihiko Hirota, Shozo Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
title | Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
title_full | Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
title_fullStr | Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
title_full_unstemmed | Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
title_short | Dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
title_sort | dosimetric and delivery characterizations of full-arc and half-arc volumetric-modulated arc therapy for maxillary cancer |
topic | Technology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3430421/ https://www.ncbi.nlm.nih.gov/pubmed/22843367 http://dx.doi.org/10.1093/jrr/rrs031 |
work_keys_str_mv | AT miurahideharu dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT fujiwaramasayuki dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT tanookamasao dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT doihiroshi dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT inouehiroyuki dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT takadayasuhiro dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT kamikonyanorihiko dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer AT hirotashozo dosimetricanddeliverycharacterizationsoffullarcandhalfarcvolumetricmodulatedarctherapyformaxillarycancer |