Cargando…
Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup
In this study, we demonstrate the increased performance in speed and sensitivity achieved by the use of small AFM cantilevers on a standard AFM system. For this, small rectangular silicon oxynitride cantilevers were utilized to arrive at faster atomic force microscopy (AFM) imaging times and more se...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Pergamon Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3430863/ https://www.ncbi.nlm.nih.gov/pubmed/22721963 http://dx.doi.org/10.1016/j.micron.2012.05.007 |
_version_ | 1782241991291043840 |
---|---|
author | Leitner, Michael Fantner, Georg E. Fantner, Ernest J. Ivanova, Katerina Ivanov, Tzvetan Rangelow, Ivo Ebner, Andreas Rangl, Martina Tang, Jilin Hinterdorfer, Peter |
author_facet | Leitner, Michael Fantner, Georg E. Fantner, Ernest J. Ivanova, Katerina Ivanov, Tzvetan Rangelow, Ivo Ebner, Andreas Rangl, Martina Tang, Jilin Hinterdorfer, Peter |
author_sort | Leitner, Michael |
collection | PubMed |
description | In this study, we demonstrate the increased performance in speed and sensitivity achieved by the use of small AFM cantilevers on a standard AFM system. For this, small rectangular silicon oxynitride cantilevers were utilized to arrive at faster atomic force microscopy (AFM) imaging times and more sensitive molecular recognition force spectroscopy (MRFS) experiments. The cantilevers we used had lengths between 13 and 46 μm, a width of about 11 μm, and a thickness between 150 and 600 nm. They were coated with chromium and gold on the backside for a better laser reflection. We characterized these small cantilevers through their frequency spectrum and with electron microscopy. Due to their small size and high resonance frequency we were able to increase the imaging speed by a factor of 10 without any loss in resolution for images from several μm scansize down to the nanometer scale. This was shown on bacterial surface layers (s-layer) with tapping mode under aqueous, near physiological conditions and on nuclear membranes in contact mode in ambient environment. In addition, we showed that single molecular forces can be measured with an up to 5 times higher force sensitivity in comparison to conventional cantilevers with similar spring constants. |
format | Online Article Text |
id | pubmed-3430863 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Pergamon Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34308632012-12-01 Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup Leitner, Michael Fantner, Georg E. Fantner, Ernest J. Ivanova, Katerina Ivanov, Tzvetan Rangelow, Ivo Ebner, Andreas Rangl, Martina Tang, Jilin Hinterdorfer, Peter Micron Article In this study, we demonstrate the increased performance in speed and sensitivity achieved by the use of small AFM cantilevers on a standard AFM system. For this, small rectangular silicon oxynitride cantilevers were utilized to arrive at faster atomic force microscopy (AFM) imaging times and more sensitive molecular recognition force spectroscopy (MRFS) experiments. The cantilevers we used had lengths between 13 and 46 μm, a width of about 11 μm, and a thickness between 150 and 600 nm. They were coated with chromium and gold on the backside for a better laser reflection. We characterized these small cantilevers through their frequency spectrum and with electron microscopy. Due to their small size and high resonance frequency we were able to increase the imaging speed by a factor of 10 without any loss in resolution for images from several μm scansize down to the nanometer scale. This was shown on bacterial surface layers (s-layer) with tapping mode under aqueous, near physiological conditions and on nuclear membranes in contact mode in ambient environment. In addition, we showed that single molecular forces can be measured with an up to 5 times higher force sensitivity in comparison to conventional cantilevers with similar spring constants. Pergamon Press 2012-12 /pmc/articles/PMC3430863/ /pubmed/22721963 http://dx.doi.org/10.1016/j.micron.2012.05.007 Text en © 2012 Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/3.0/ Open Access under CC BY-NC-ND 3.0 (https://creativecommons.org/licenses/by-nc-nd/3.0/) license |
spellingShingle | Article Leitner, Michael Fantner, Georg E. Fantner, Ernest J. Ivanova, Katerina Ivanov, Tzvetan Rangelow, Ivo Ebner, Andreas Rangl, Martina Tang, Jilin Hinterdorfer, Peter Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup |
title | Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup |
title_full | Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup |
title_fullStr | Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup |
title_full_unstemmed | Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup |
title_short | Increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional AFM setup |
title_sort | increased imaging speed and force sensitivity for bio-applications with small cantilevers using a conventional afm setup |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3430863/ https://www.ncbi.nlm.nih.gov/pubmed/22721963 http://dx.doi.org/10.1016/j.micron.2012.05.007 |
work_keys_str_mv | AT leitnermichael increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT fantnergeorge increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT fantnerernestj increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT ivanovakaterina increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT ivanovtzvetan increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT rangelowivo increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT ebnerandreas increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT ranglmartina increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT tangjilin increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup AT hinterdorferpeter increasedimagingspeedandforcesensitivityforbioapplicationswithsmallcantileversusingaconventionalafmsetup |