Cargando…

Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty

BACKGROUND: To assess repeatability of the Zhongshan Assessment Program (ZAP) software measurement of Anterior Segment Optical Coherence Tomography (ASOCT) images and correlate with graft trephine diameter following Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) METHODS: Retrospective...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Gavin S, He, Mingguang, Tan, Donald T, Mehta, Jodhbir S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3431259/
https://www.ncbi.nlm.nih.gov/pubmed/22824516
http://dx.doi.org/10.1186/1471-2342-12-19
_version_ 1782242049674706944
author Tan, Gavin S
He, Mingguang
Tan, Donald T
Mehta, Jodhbir S
author_facet Tan, Gavin S
He, Mingguang
Tan, Donald T
Mehta, Jodhbir S
author_sort Tan, Gavin S
collection PubMed
description BACKGROUND: To assess repeatability of the Zhongshan Assessment Program (ZAP) software measurement of Anterior Segment Optical Coherence Tomography (ASOCT) images and correlate with graft trephine diameter following Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) METHODS: Retrospectively evaluated interventional case series. 121 consecutive eyes undergoing DSAEK over a 26 month period underwent ASOCT imaging 1month after their surgery. ASOCT images were processed using ZAP software which measured the graft and cornea parameters including anterior and posterior graft arc length and cord length, posterior cornea arc length (PCAL) and anterior chamber width. RESULTS: The graft measurements showed good repeatability on ASOCT using ZAP with high intra class coefficient and small variation in the coefficient of variation. On ASOCT, the mean recipient PCAL was 12.99+/−0.69mm and the anterior chamber width was 11.16+/−0.57mm. The mean Graft anterior arc length was 9.69+/−0.66mm and the mean Graft anterior cord length was 8.92+/−2.94mm. The mean graft posterior arc length was 9.24+/−0.75mm and the mean graft posterior cord length was 8.15+/−0.57mm. Graft posterior arc length (rho=0.788, p< 0.001) correlated best with intra-operative graft trephine diameter. The mean ratio of posterior graft arc length to PCAL was 0.712 +/− 0.056. CONCLUSIONS: We have validated the repeatability of the ZAP software for DSAEK graft measurements from ASOCT images and shown that the graft arc length parameters calculated from the ASOCT images correlate well with the intra-operative graft trephine diameter. This software may help surgeons determine the optimal DSAEK graft size based on pre-operative ASOCT measurements of the recipient eye.
format Online
Article
Text
id pubmed-3431259
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34312592012-08-31 Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty Tan, Gavin S He, Mingguang Tan, Donald T Mehta, Jodhbir S BMC Med Imaging Research Article BACKGROUND: To assess repeatability of the Zhongshan Assessment Program (ZAP) software measurement of Anterior Segment Optical Coherence Tomography (ASOCT) images and correlate with graft trephine diameter following Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) METHODS: Retrospectively evaluated interventional case series. 121 consecutive eyes undergoing DSAEK over a 26 month period underwent ASOCT imaging 1month after their surgery. ASOCT images were processed using ZAP software which measured the graft and cornea parameters including anterior and posterior graft arc length and cord length, posterior cornea arc length (PCAL) and anterior chamber width. RESULTS: The graft measurements showed good repeatability on ASOCT using ZAP with high intra class coefficient and small variation in the coefficient of variation. On ASOCT, the mean recipient PCAL was 12.99+/−0.69mm and the anterior chamber width was 11.16+/−0.57mm. The mean Graft anterior arc length was 9.69+/−0.66mm and the mean Graft anterior cord length was 8.92+/−2.94mm. The mean graft posterior arc length was 9.24+/−0.75mm and the mean graft posterior cord length was 8.15+/−0.57mm. Graft posterior arc length (rho=0.788, p< 0.001) correlated best with intra-operative graft trephine diameter. The mean ratio of posterior graft arc length to PCAL was 0.712 +/− 0.056. CONCLUSIONS: We have validated the repeatability of the ZAP software for DSAEK graft measurements from ASOCT images and shown that the graft arc length parameters calculated from the ASOCT images correlate well with the intra-operative graft trephine diameter. This software may help surgeons determine the optimal DSAEK graft size based on pre-operative ASOCT measurements of the recipient eye. BioMed Central 2012-07-23 /pmc/articles/PMC3431259/ /pubmed/22824516 http://dx.doi.org/10.1186/1471-2342-12-19 Text en Copyright ©2012 Tan et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tan, Gavin S
He, Mingguang
Tan, Donald T
Mehta, Jodhbir S
Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
title Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
title_full Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
title_fullStr Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
title_full_unstemmed Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
title_short Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
title_sort correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3431259/
https://www.ncbi.nlm.nih.gov/pubmed/22824516
http://dx.doi.org/10.1186/1471-2342-12-19
work_keys_str_mv AT tangavins correlationofanteriorsegmentopticalcoherencetomographymeasurementswithgrafttrephinediameterfollowingdescemetstrippingautomatedendothelialkeratoplasty
AT hemingguang correlationofanteriorsegmentopticalcoherencetomographymeasurementswithgrafttrephinediameterfollowingdescemetstrippingautomatedendothelialkeratoplasty
AT tandonaldt correlationofanteriorsegmentopticalcoherencetomographymeasurementswithgrafttrephinediameterfollowingdescemetstrippingautomatedendothelialkeratoplasty
AT mehtajodhbirs correlationofanteriorsegmentopticalcoherencetomographymeasurementswithgrafttrephinediameterfollowingdescemetstrippingautomatedendothelialkeratoplasty