Cargando…

Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS

OBJECTIVES: Although phthalates like dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) are commonly used as plasticizers and their metabolites are especially suspected of reproductive toxicity, little is known about occupational exposure to those phthalates. The aim of this study was to a...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Jee Yeon, Lee, Ji Hyun, Kim, Eun Young, Kim, Pan Gyi, Kho, Young Lim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Occupational Safety and Health Research Institute 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3431890/
https://www.ncbi.nlm.nih.gov/pubmed/22953188
http://dx.doi.org/10.5491/SHAW.2011.2.1.57
_version_ 1782242124964560896
author Jeong, Jee Yeon
Lee, Ji Hyun
Kim, Eun Young
Kim, Pan Gyi
Kho, Young Lim
author_facet Jeong, Jee Yeon
Lee, Ji Hyun
Kim, Eun Young
Kim, Pan Gyi
Kho, Young Lim
author_sort Jeong, Jee Yeon
collection PubMed
description OBJECTIVES: Although phthalates like dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) are commonly used as plasticizers and their metabolites are especially suspected of reproductive toxicity, little is known about occupational exposure to those phthalates. The aim of this study was to assess the utility of measuring the metabolite concentrations of DBP and DEHP in serum and urine samples as an indicator of occupational exposure to those phthalates. METHODS: Phthalate metabolites were analyzed by using column-switching high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS). RESULTS: We detected phthalate metabolites in serum and urine matrices at approximately 10-fold lower than the limit of detection of those metabolites in the same matrix by LC-MS/MS without column switching, which was sufficient to evaluate concentrations of phthalate metabolites for industrial workers and the general population. CONCLUSION: The accuracy and precision of the analytical method indicate that urinary metabolite determination can be a more acceptable biomarker for studying phthalate exposure and adverse health outcomes.
format Online
Article
Text
id pubmed-3431890
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher Occupational Safety and Health Research Institute
record_format MEDLINE/PubMed
spelling pubmed-34318902012-09-05 Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS Jeong, Jee Yeon Lee, Ji Hyun Kim, Eun Young Kim, Pan Gyi Kho, Young Lim Saf Health Work Original Article OBJECTIVES: Although phthalates like dibutyl phthalate (DBP) and di-2-ethylhexyl phthalate (DEHP) are commonly used as plasticizers and their metabolites are especially suspected of reproductive toxicity, little is known about occupational exposure to those phthalates. The aim of this study was to assess the utility of measuring the metabolite concentrations of DBP and DEHP in serum and urine samples as an indicator of occupational exposure to those phthalates. METHODS: Phthalate metabolites were analyzed by using column-switching high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS). RESULTS: We detected phthalate metabolites in serum and urine matrices at approximately 10-fold lower than the limit of detection of those metabolites in the same matrix by LC-MS/MS without column switching, which was sufficient to evaluate concentrations of phthalate metabolites for industrial workers and the general population. CONCLUSION: The accuracy and precision of the analytical method indicate that urinary metabolite determination can be a more acceptable biomarker for studying phthalate exposure and adverse health outcomes. Occupational Safety and Health Research Institute 2011-03 2011-03-31 /pmc/articles/PMC3431890/ /pubmed/22953188 http://dx.doi.org/10.5491/SHAW.2011.2.1.57 Text en Copyright © 2011 by Safety and Health at Work (SH@W) http://creativecommons.org/licenses/by-nc/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Jeong, Jee Yeon
Lee, Ji Hyun
Kim, Eun Young
Kim, Pan Gyi
Kho, Young Lim
Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
title Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
title_full Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
title_fullStr Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
title_full_unstemmed Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
title_short Determination of Phthalate Metabolites in Human Serum and Urine as Biomarkers for Phthalate Exposure Using Column-Switching LC-MS/MS
title_sort determination of phthalate metabolites in human serum and urine as biomarkers for phthalate exposure using column-switching lc-ms/ms
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3431890/
https://www.ncbi.nlm.nih.gov/pubmed/22953188
http://dx.doi.org/10.5491/SHAW.2011.2.1.57
work_keys_str_mv AT jeongjeeyeon determinationofphthalatemetabolitesinhumanserumandurineasbiomarkersforphthalateexposureusingcolumnswitchinglcmsms
AT leejihyun determinationofphthalatemetabolitesinhumanserumandurineasbiomarkersforphthalateexposureusingcolumnswitchinglcmsms
AT kimeunyoung determinationofphthalatemetabolitesinhumanserumandurineasbiomarkersforphthalateexposureusingcolumnswitchinglcmsms
AT kimpangyi determinationofphthalatemetabolitesinhumanserumandurineasbiomarkersforphthalateexposureusingcolumnswitchinglcmsms
AT khoyounglim determinationofphthalatemetabolitesinhumanserumandurineasbiomarkersforphthalateexposureusingcolumnswitchinglcmsms