Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange

Fibrin sheath formation around long-term haemodialysis catheter is a common cause of failed dialysis access. Treatment options include pharmacological and mechanical methods. This paper reports a case of failed dialysis access due to fibrin sheath encasement. Pharmacologic thrombolysis, mechanical d...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohamad Ali, AF, Uhwut, E, Liew, SK
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3432227/
https://www.ncbi.nlm.nih.gov/pubmed/22970064
http://dx.doi.org/10.2349/biij.8.1.e8
_version_ 1782242185788260352
author Mohamad Ali, AF
Uhwut, E
Liew, SK
author_facet Mohamad Ali, AF
Uhwut, E
Liew, SK
author_sort Mohamad Ali, AF
collection PubMed
description Fibrin sheath formation around long-term haemodialysis catheter is a common cause of failed dialysis access. Treatment options include pharmacological and mechanical methods. This paper reports a case of failed dialysis access due to fibrin sheath encasement. Pharmacologic thrombolysis, mechanical disruption using guide wire and catheter exchange had failed to address the issue. Eventually, fibrin sheath stripping using the loop snare technique was able to successfully restore the catheter function.
format Online
Article
Text
id pubmed-3432227
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia
record_format MEDLINE/PubMed
spelling pubmed-34322272012-09-11 Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange Mohamad Ali, AF Uhwut, E Liew, SK Biomed Imaging Interv J Case Report Fibrin sheath formation around long-term haemodialysis catheter is a common cause of failed dialysis access. Treatment options include pharmacological and mechanical methods. This paper reports a case of failed dialysis access due to fibrin sheath encasement. Pharmacologic thrombolysis, mechanical disruption using guide wire and catheter exchange had failed to address the issue. Eventually, fibrin sheath stripping using the loop snare technique was able to successfully restore the catheter function. Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia 2012-01-01 /pmc/articles/PMC3432227/ /pubmed/22970064 http://dx.doi.org/10.2349/biij.8.1.e8 Text en © 2012 Biomedical Imaging and Intervention Journal http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Mohamad Ali, AF
Uhwut, E
Liew, SK
Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
title Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
title_full Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
title_fullStr Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
title_full_unstemmed Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
title_short Dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
title_sort dialysis catheter fibrin sheath stripping: a useful technique after failed catheter exchange
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3432227/
https://www.ncbi.nlm.nih.gov/pubmed/22970064
http://dx.doi.org/10.2349/biij.8.1.e8
work_keys_str_mv AT mohamadaliaf dialysiscatheterfibrinsheathstrippingausefultechniqueafterfailedcatheterexchange
AT uhwute dialysiscatheterfibrinsheathstrippingausefultechniqueafterfailedcatheterexchange
AT liewsk dialysiscatheterfibrinsheathstrippingausefultechniqueafterfailedcatheterexchange