Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method

Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were c...

Descripción completa

Detalles Bibliográficos
Autores principales: Bonfante, Estevam A., Witek, Lukasz, Tovar, Nick, Suzuki, Marcelo, Marin, Charles, Granato, Rodrigo, Coelho, Paulo G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3434399/
https://www.ncbi.nlm.nih.gov/pubmed/22969806
http://dx.doi.org/10.1155/2012/603826
_version_ 1782242436493344768
author Bonfante, Estevam A.
Witek, Lukasz
Tovar, Nick
Suzuki, Marcelo
Marin, Charles
Granato, Rodrigo
Coelho, Paulo G.
author_facet Bonfante, Estevam A.
Witek, Lukasz
Tovar, Nick
Suzuki, Marcelo
Marin, Charles
Granato, Rodrigo
Coelho, Paulo G.
author_sort Bonfante, Estevam A.
collection PubMed
description Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants.
format Online
Article
Text
id pubmed-3434399
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-34343992012-09-11 Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method Bonfante, Estevam A. Witek, Lukasz Tovar, Nick Suzuki, Marcelo Marin, Charles Granato, Rodrigo Coelho, Paulo G. Int J Biomater Research Article Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants. Hindawi Publishing Corporation 2012 2012-08-27 /pmc/articles/PMC3434399/ /pubmed/22969806 http://dx.doi.org/10.1155/2012/603826 Text en Copyright © 2012 Estevam A. Bonfante et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Bonfante, Estevam A.
Witek, Lukasz
Tovar, Nick
Suzuki, Marcelo
Marin, Charles
Granato, Rodrigo
Coelho, Paulo G.
Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
title Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
title_full Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
title_fullStr Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
title_full_unstemmed Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
title_short Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
title_sort physicochemical characterization and in vivo evaluation of amorphous and partially crystalline calcium phosphate coatings fabricated on ti-6al-4v implants by the plasma spray method
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3434399/
https://www.ncbi.nlm.nih.gov/pubmed/22969806
http://dx.doi.org/10.1155/2012/603826
work_keys_str_mv AT bonfanteestevama physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod
AT witeklukasz physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod
AT tovarnick physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod
AT suzukimarcelo physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod
AT marincharles physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod
AT granatorodrigo physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod
AT coelhopaulog physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod