Cargando…
Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method
Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were c...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3434399/ https://www.ncbi.nlm.nih.gov/pubmed/22969806 http://dx.doi.org/10.1155/2012/603826 |
_version_ | 1782242436493344768 |
---|---|
author | Bonfante, Estevam A. Witek, Lukasz Tovar, Nick Suzuki, Marcelo Marin, Charles Granato, Rodrigo Coelho, Paulo G. |
author_facet | Bonfante, Estevam A. Witek, Lukasz Tovar, Nick Suzuki, Marcelo Marin, Charles Granato, Rodrigo Coelho, Paulo G. |
author_sort | Bonfante, Estevam A. |
collection | PubMed |
description | Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants. |
format | Online Article Text |
id | pubmed-3434399 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-34343992012-09-11 Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method Bonfante, Estevam A. Witek, Lukasz Tovar, Nick Suzuki, Marcelo Marin, Charles Granato, Rodrigo Coelho, Paulo G. Int J Biomater Research Article Objective. To characterize the topographic and chemical properties of 2 bioceramic coated plateau root form implant surfaces and evaluate their histomorphometric differences at 6 and 12 weeks in vivo. Methods. Plasma sprayed hydroxyapatite (PSHA) and amorphous calcium phosphate (ACP) surfaces were characterized by scanning electron microscopy (SEM), interferometry (IFM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). Implants were placed in the radius epiphysis, and the right limb of dogs provided implants that remained for 6 weeks, and the left limb provided implants that remained 12 weeks in vivo. Thin sections were prepared for bone-to-implant contact (BIC) and bone-area-fraction occupancy (BAFO) measurements (evaluated by Friedman analysis P < 0.05). Results. Significantly, higher S(a) (P < 0.03) and S(q) (P < 0.02) were observed for ACP relative to PSHA. Chemical analysis revealed significantly higher HA, calcium phosphate, and calcium pyrophosphate for the PSHA surface. BIC and BAFO measurements showed no differences between surfaces. Lamellar bone formation in close contact with implant surfaces and within the healing chambers was observed for both groups. Conclusion. Given topographical and chemical differences between PSHA and ACP surfaces, bone morphology and histomorphometric evaluated parameters showed that both surfaces were osseoconductive in plateau root form implants. Hindawi Publishing Corporation 2012 2012-08-27 /pmc/articles/PMC3434399/ /pubmed/22969806 http://dx.doi.org/10.1155/2012/603826 Text en Copyright © 2012 Estevam A. Bonfante et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Bonfante, Estevam A. Witek, Lukasz Tovar, Nick Suzuki, Marcelo Marin, Charles Granato, Rodrigo Coelho, Paulo G. Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method |
title | Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method |
title_full | Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method |
title_fullStr | Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method |
title_full_unstemmed | Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method |
title_short | Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method |
title_sort | physicochemical characterization and in vivo evaluation of amorphous and partially crystalline calcium phosphate coatings fabricated on ti-6al-4v implants by the plasma spray method |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3434399/ https://www.ncbi.nlm.nih.gov/pubmed/22969806 http://dx.doi.org/10.1155/2012/603826 |
work_keys_str_mv | AT bonfanteestevama physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod AT witeklukasz physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod AT tovarnick physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod AT suzukimarcelo physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod AT marincharles physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod AT granatorodrigo physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod AT coelhopaulog physicochemicalcharacterizationandinvivoevaluationofamorphousandpartiallycrystallinecalciumphosphatecoatingsfabricatedonti6al4vimplantsbytheplasmaspraymethod |