Cargando…

National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses

OBJECTIVE: To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. MATERIALS AND METHODS: The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest rad...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Bo Hyun, Do, Kyung-Hyun, Goo, Hyun Woo, Yang, Dong Hyun, Oh, Sang Young, Kim, Hyeog Ju, Lee, Kwang Yong, Lee, Jung Eun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3435859/
https://www.ncbi.nlm.nih.gov/pubmed/22977329
http://dx.doi.org/10.3348/kjr.2012.13.5.610
_version_ 1782242603488509952
author Kim, Bo Hyun
Do, Kyung-Hyun
Goo, Hyun Woo
Yang, Dong Hyun
Oh, Sang Young
Kim, Hyeog Ju
Lee, Kwang Yong
Lee, Jung Eun
author_facet Kim, Bo Hyun
Do, Kyung-Hyun
Goo, Hyun Woo
Yang, Dong Hyun
Oh, Sang Young
Kim, Hyeog Ju
Lee, Kwang Yong
Lee, Jung Eun
author_sort Kim, Bo Hyun
collection PubMed
description OBJECTIVE: To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. MATERIALS AND METHODS: The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a phantom representing a 5-year-old child (ATOM® dosimetry phantom, model 705-D, CIRS, Norfolk, VA, USA) with each hospital's own protocol. Five glass dosimeters (M-GD352M, Asahi Techno Glass Corporation, Shizuoka, Japan) were horizontally installed at the center of the phantom to measure the dose. Other factors including machine's radiography system, presence of dedicated pediatric radiography machine, presence of an attending pediatric radiologist, and the use of automatic exposure control (AEC) were also evaluated. RESULTS: The average protocol for pediatric chest radiography examination in Korea was 94.9 peak kilovoltage and 4.30 milliampere second. The mean entrance surface dose (ESD) during a single examination was 140.4 microgray (µGy). The third quartile, median, minimum and maximum value of ESD were 160.8 µGy, 93.4 µGy, 18.8 µGy, and 2334.6 µGy, respectively. There was no significant dose difference between digital and non-digital radiography systems. The use of AEC significantly reduced radiation doses of pediatric chest radiographs (p < 0.001). CONCLUSION: Our nationwide survey shows that the third quartile, median, and mean ESD for pediatric chest radiograph is 160.8 µGy, 93.4 µGy, and 140.4 µGy, respectively. No significant dose difference is noticed between digital and non-digital radiography systems, and the use of AEC helps significantly reduce radiation doses.
format Online
Article
Text
id pubmed-3435859
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher The Korean Society of Radiology
record_format MEDLINE/PubMed
spelling pubmed-34358592012-09-13 National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses Kim, Bo Hyun Do, Kyung-Hyun Goo, Hyun Woo Yang, Dong Hyun Oh, Sang Young Kim, Hyeog Ju Lee, Kwang Yong Lee, Jung Eun Korean J Radiol Original Article OBJECTIVE: To investigate radiation doses in pediatric chest radiography in a national survey and to analyze the factors that affect radiation doses. MATERIALS AND METHODS: The study was based on the results of 149 chest radiography machines in 135 hospitals nationwide. For each machine, a chest radiograph was obtained by using a phantom representing a 5-year-old child (ATOM® dosimetry phantom, model 705-D, CIRS, Norfolk, VA, USA) with each hospital's own protocol. Five glass dosimeters (M-GD352M, Asahi Techno Glass Corporation, Shizuoka, Japan) were horizontally installed at the center of the phantom to measure the dose. Other factors including machine's radiography system, presence of dedicated pediatric radiography machine, presence of an attending pediatric radiologist, and the use of automatic exposure control (AEC) were also evaluated. RESULTS: The average protocol for pediatric chest radiography examination in Korea was 94.9 peak kilovoltage and 4.30 milliampere second. The mean entrance surface dose (ESD) during a single examination was 140.4 microgray (µGy). The third quartile, median, minimum and maximum value of ESD were 160.8 µGy, 93.4 µGy, 18.8 µGy, and 2334.6 µGy, respectively. There was no significant dose difference between digital and non-digital radiography systems. The use of AEC significantly reduced radiation doses of pediatric chest radiographs (p < 0.001). CONCLUSION: Our nationwide survey shows that the third quartile, median, and mean ESD for pediatric chest radiograph is 160.8 µGy, 93.4 µGy, and 140.4 µGy, respectively. No significant dose difference is noticed between digital and non-digital radiography systems, and the use of AEC helps significantly reduce radiation doses. The Korean Society of Radiology 2012 2012-08-28 /pmc/articles/PMC3435859/ /pubmed/22977329 http://dx.doi.org/10.3348/kjr.2012.13.5.610 Text en Copyright © 2012 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Bo Hyun
Do, Kyung-Hyun
Goo, Hyun Woo
Yang, Dong Hyun
Oh, Sang Young
Kim, Hyeog Ju
Lee, Kwang Yong
Lee, Jung Eun
National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses
title National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses
title_full National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses
title_fullStr National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses
title_full_unstemmed National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses
title_short National Survey of Radiation Doses of Pediatric Chest Radiography in Korea: Analysis of the Factors Affecting Radiation Doses
title_sort national survey of radiation doses of pediatric chest radiography in korea: analysis of the factors affecting radiation doses
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3435859/
https://www.ncbi.nlm.nih.gov/pubmed/22977329
http://dx.doi.org/10.3348/kjr.2012.13.5.610
work_keys_str_mv AT kimbohyun nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT dokyunghyun nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT goohyunwoo nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT yangdonghyun nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT ohsangyoung nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT kimhyeogju nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT leekwangyong nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses
AT leejungeun nationalsurveyofradiationdosesofpediatricchestradiographyinkoreaanalysisofthefactorsaffectingradiationdoses