Cargando…
A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs
An indium nitride (InN) gas sensor of 10 nm in thickness has achieved detection limit of 0.4 ppm acetone. The sensor has a size of 1 mm by 2.5 mm, while its sensing area is 0.25 mm by 2 mm. Detection of such a low acetone concentration in exhaled breath could enable early diagnosis of diabetes for p...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3435971/ https://www.ncbi.nlm.nih.gov/pubmed/22969342 http://dx.doi.org/10.3390/s120607157 |
_version_ | 1782242626226880512 |
---|---|
author | Kao, Kun-Wei Hsu, Ming-Che Chang, Yuh-Hwa Gwo, Shangjr Yeh, J. Andrew |
author_facet | Kao, Kun-Wei Hsu, Ming-Che Chang, Yuh-Hwa Gwo, Shangjr Yeh, J. Andrew |
author_sort | Kao, Kun-Wei |
collection | PubMed |
description | An indium nitride (InN) gas sensor of 10 nm in thickness has achieved detection limit of 0.4 ppm acetone. The sensor has a size of 1 mm by 2.5 mm, while its sensing area is 0.25 mm by 2 mm. Detection of such a low acetone concentration in exhaled breath could enable early diagnosis of diabetes for portable physiological applications. The ultrathin InN epilayer extensively enhances sensing sensitivity due to its strong electron accumulation on roughly 5–10 nm deep layers from the surface. Platinum as catalyst can increase output current signals by 2.5-fold (94 vs. 37.5 μA) as well as reduce response time by 8.4-fold (150 vs. 1,260 s) in comparison with bare InN. More, the effect of 3% oxygen consumption due to breath inhalation and exhalation on 2.4 ppm acetone gas detection was investigated, indicating that such an acetone concentration can be analyzed in air. |
format | Online Article Text |
id | pubmed-3435971 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-34359712012-09-11 A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs Kao, Kun-Wei Hsu, Ming-Che Chang, Yuh-Hwa Gwo, Shangjr Yeh, J. Andrew Sensors (Basel) Article An indium nitride (InN) gas sensor of 10 nm in thickness has achieved detection limit of 0.4 ppm acetone. The sensor has a size of 1 mm by 2.5 mm, while its sensing area is 0.25 mm by 2 mm. Detection of such a low acetone concentration in exhaled breath could enable early diagnosis of diabetes for portable physiological applications. The ultrathin InN epilayer extensively enhances sensing sensitivity due to its strong electron accumulation on roughly 5–10 nm deep layers from the surface. Platinum as catalyst can increase output current signals by 2.5-fold (94 vs. 37.5 μA) as well as reduce response time by 8.4-fold (150 vs. 1,260 s) in comparison with bare InN. More, the effect of 3% oxygen consumption due to breath inhalation and exhalation on 2.4 ppm acetone gas detection was investigated, indicating that such an acetone concentration can be analyzed in air. Molecular Diversity Preservation International (MDPI) 2012-05-29 /pmc/articles/PMC3435971/ /pubmed/22969342 http://dx.doi.org/10.3390/s120607157 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Kao, Kun-Wei Hsu, Ming-Che Chang, Yuh-Hwa Gwo, Shangjr Yeh, J. Andrew A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs |
title | A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs |
title_full | A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs |
title_fullStr | A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs |
title_full_unstemmed | A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs |
title_short | A Sub-ppm Acetone Gas Sensor for Diabetes Detection Using 10 nm Thick Ultrathin InN FETs |
title_sort | sub-ppm acetone gas sensor for diabetes detection using 10 nm thick ultrathin inn fets |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3435971/ https://www.ncbi.nlm.nih.gov/pubmed/22969342 http://dx.doi.org/10.3390/s120607157 |
work_keys_str_mv | AT kaokunwei asubppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT hsumingche asubppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT changyuhhwa asubppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT gwoshangjr asubppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT yehjandrew asubppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT kaokunwei subppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT hsumingche subppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT changyuhhwa subppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT gwoshangjr subppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets AT yehjandrew subppmacetonegassensorfordiabetesdetectionusing10nmthickultrathininnfets |