Cargando…
The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study
BACKGROUND: Physical loading leads to a deformation of bone microstructure and may influence quantitative ultrasound (QUS) parameters. This study aims at evaluating the effect of physical loading on bone QUS measurement, and further, on the potential of diagnosing osteoporosis using QUS method under...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3436732/ https://www.ncbi.nlm.nih.gov/pubmed/22584084 http://dx.doi.org/10.1186/1471-2474-13-70 |
_version_ | 1782242682524925952 |
---|---|
author | Liu, Cheng-Rui Niu, Hai-Jun Pu, Fang Wang, Ling Sun, Lian-Wen Fan, Yu-Bo Li, De-Yu |
author_facet | Liu, Cheng-Rui Niu, Hai-Jun Pu, Fang Wang, Ling Sun, Lian-Wen Fan, Yu-Bo Li, De-Yu |
author_sort | Liu, Cheng-Rui |
collection | PubMed |
description | BACKGROUND: Physical loading leads to a deformation of bone microstructure and may influence quantitative ultrasound (QUS) parameters. This study aims at evaluating the effect of physical loading on bone QUS measurement, and further, on the potential of diagnosing osteoporosis using QUS method under physical loading condition. METHODS: 16 healthy young females (control group) and 45 postmenopausal women (divided into 3 groups according to the years since menopause (YSM)) were studied. QUS parameters were measured at calcaneus under self-weight loading (standing) and no loading (sitting) conditions. Weight-normalized QUS parameter (QUS parameter measured under loading condition divided by the weight of the subject) was proposed to evaluate the influence of loading. T-test, One-Way analysis of variance (one way ANOVA) and receiver operating characteristic (ROC) analysis were applied for analysis. RESULTS: In QUS parameters, mainly normalized broadband ultrasound attenuation (nBUA), measured with loading significantly differed from those measured without loading (p < 0.05). The relative changes of weight-normalized QUS parameters on postmenopausal women with respect to premenopausal women under loading condition were larger than those on traditional QUS parameters measured without loading. In ROC analysis, weight-normalized QUS parameters showed their stronger discriminatory ability for menopause. CONCLUSIONS: Physical loading substantially influenced bone QUS measurement (mainly nBUA). Weight-normalized QUS parameters can discriminate menopause more effectively. By considering the high relationship between menopause and osteoporosis, an inference was drawn that adding physical loading during measurement may be a probable way to improve the QUS based osteoporosis diagnosis. |
format | Online Article Text |
id | pubmed-3436732 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34367322012-09-11 The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study Liu, Cheng-Rui Niu, Hai-Jun Pu, Fang Wang, Ling Sun, Lian-Wen Fan, Yu-Bo Li, De-Yu BMC Musculoskelet Disord Research Article BACKGROUND: Physical loading leads to a deformation of bone microstructure and may influence quantitative ultrasound (QUS) parameters. This study aims at evaluating the effect of physical loading on bone QUS measurement, and further, on the potential of diagnosing osteoporosis using QUS method under physical loading condition. METHODS: 16 healthy young females (control group) and 45 postmenopausal women (divided into 3 groups according to the years since menopause (YSM)) were studied. QUS parameters were measured at calcaneus under self-weight loading (standing) and no loading (sitting) conditions. Weight-normalized QUS parameter (QUS parameter measured under loading condition divided by the weight of the subject) was proposed to evaluate the influence of loading. T-test, One-Way analysis of variance (one way ANOVA) and receiver operating characteristic (ROC) analysis were applied for analysis. RESULTS: In QUS parameters, mainly normalized broadband ultrasound attenuation (nBUA), measured with loading significantly differed from those measured without loading (p < 0.05). The relative changes of weight-normalized QUS parameters on postmenopausal women with respect to premenopausal women under loading condition were larger than those on traditional QUS parameters measured without loading. In ROC analysis, weight-normalized QUS parameters showed their stronger discriminatory ability for menopause. CONCLUSIONS: Physical loading substantially influenced bone QUS measurement (mainly nBUA). Weight-normalized QUS parameters can discriminate menopause more effectively. By considering the high relationship between menopause and osteoporosis, an inference was drawn that adding physical loading during measurement may be a probable way to improve the QUS based osteoporosis diagnosis. BioMed Central 2012-05-14 /pmc/articles/PMC3436732/ /pubmed/22584084 http://dx.doi.org/10.1186/1471-2474-13-70 Text en Copyright ©2012 Liu et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Liu, Cheng-Rui Niu, Hai-Jun Pu, Fang Wang, Ling Sun, Lian-Wen Fan, Yu-Bo Li, De-Yu The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
title | The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
title_full | The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
title_fullStr | The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
title_full_unstemmed | The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
title_short | The effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
title_sort | effect of physical loading on calcaneus quantitative ultrasound measurement: a cross-section study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3436732/ https://www.ncbi.nlm.nih.gov/pubmed/22584084 http://dx.doi.org/10.1186/1471-2474-13-70 |
work_keys_str_mv | AT liuchengrui theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT niuhaijun theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT pufang theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT wangling theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT sunlianwen theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT fanyubo theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT lideyu theeffectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT liuchengrui effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT niuhaijun effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT pufang effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT wangling effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT sunlianwen effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT fanyubo effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy AT lideyu effectofphysicalloadingoncalcaneusquantitativeultrasoundmeasurementacrosssectionstudy |