Cargando…
Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
This study aims to generate the normalized mean organ dose factors (mGy min(-1) GBq(-1)) to healthy organs during brachytherapy treatment of esophagus, breast, and neck cancers specific to the patient population in India. This study is in continuation to the earlier published studies on the estimati...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3437172/ https://www.ncbi.nlm.nih.gov/pubmed/22973082 http://dx.doi.org/10.4103/0971-6203.99238 |
Sumario: | This study aims to generate the normalized mean organ dose factors (mGy min(-1) GBq(-1)) to healthy organs during brachytherapy treatment of esophagus, breast, and neck cancers specific to the patient population in India. This study is in continuation to the earlier published studies on the estimation of organ doses during uterus brachytherapy treatments. The results are obtained by Monte Carlo simulation of radiation transport through MIRD type anthropomorphic mathematical phantom representing reference Indian adult with (192)Ir and (60)Co high dose rate sources in the esophagus, breast, and neck of the phantom. The result of this study is compared with a published computational study using voxel-based phantom model. The variation in the organ dose of this study to the published values is within 50%. |
---|