Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers

This study aims to generate the normalized mean organ dose factors (mGy min(-1) GBq(-1)) to healthy organs during brachytherapy treatment of esophagus, breast, and neck cancers specific to the patient population in India. This study is in continuation to the earlier published studies on the estimati...

Descripción completa

Detalles Bibliográficos
Autor principal: Keshavkumar, Biju
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3437172/
https://www.ncbi.nlm.nih.gov/pubmed/22973082
http://dx.doi.org/10.4103/0971-6203.99238
_version_ 1782242755407249408
author Keshavkumar, Biju
author_facet Keshavkumar, Biju
author_sort Keshavkumar, Biju
collection PubMed
description This study aims to generate the normalized mean organ dose factors (mGy min(-1) GBq(-1)) to healthy organs during brachytherapy treatment of esophagus, breast, and neck cancers specific to the patient population in India. This study is in continuation to the earlier published studies on the estimation of organ doses during uterus brachytherapy treatments. The results are obtained by Monte Carlo simulation of radiation transport through MIRD type anthropomorphic mathematical phantom representing reference Indian adult with (192)Ir and (60)Co high dose rate sources in the esophagus, breast, and neck of the phantom. The result of this study is compared with a published computational study using voxel-based phantom model. The variation in the organ dose of this study to the published values is within 50%.
format Online
Article
Text
id pubmed-3437172
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-34371722012-09-12 Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers Keshavkumar, Biju J Med Phys Original Article This study aims to generate the normalized mean organ dose factors (mGy min(-1) GBq(-1)) to healthy organs during brachytherapy treatment of esophagus, breast, and neck cancers specific to the patient population in India. This study is in continuation to the earlier published studies on the estimation of organ doses during uterus brachytherapy treatments. The results are obtained by Monte Carlo simulation of radiation transport through MIRD type anthropomorphic mathematical phantom representing reference Indian adult with (192)Ir and (60)Co high dose rate sources in the esophagus, breast, and neck of the phantom. The result of this study is compared with a published computational study using voxel-based phantom model. The variation in the organ dose of this study to the published values is within 50%. Medknow Publications & Media Pvt Ltd 2012 /pmc/articles/PMC3437172/ /pubmed/22973082 http://dx.doi.org/10.4103/0971-6203.99238 Text en Copyright: © Journal of Medical Physics http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Keshavkumar, Biju
Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
title Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
title_full Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
title_fullStr Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
title_full_unstemmed Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
title_short Computed organ doses to an Indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
title_sort computed organ doses to an indian reference adult during brachytherapy treatment of esophagus, breast, and neck cancers
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3437172/
https://www.ncbi.nlm.nih.gov/pubmed/22973082
http://dx.doi.org/10.4103/0971-6203.99238
work_keys_str_mv AT keshavkumarbiju computedorgandosestoanindianreferenceadultduringbrachytherapytreatmentofesophagusbreastandneckcancers