Cargando…
Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge
BACKGROUND AND AIMS: Diverse gauges have been used to measure and determine bracket height for correct bracket positioning. The aim of the present study was to determine and compare bracket positioning accuracy by using height bracket positioning gauge (HBPG) and Boone gauge (BG). MATERIALS AND METH...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2011
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3442432/ https://www.ncbi.nlm.nih.gov/pubmed/22991618 http://dx.doi.org/10.5681/joddd.2011.026 |
_version_ | 1782243459156934656 |
---|---|
author | Mohammadi, Amir Moslemzadeh, Seyed Hossein |
author_facet | Mohammadi, Amir Moslemzadeh, Seyed Hossein |
author_sort | Mohammadi, Amir |
collection | PubMed |
description | BACKGROUND AND AIMS: Diverse gauges have been used to measure and determine bracket height for correct bracket positioning. The aim of the present study was to determine and compare bracket positioning accuracy by using height bracket positioning gauge (HBPG) and Boone gauge (BG). MATERIALS AND METHODS: Nineteen sets of stone models were prepared from one patient. One set was employed to de-termine the ideal position of brackets, and the remaining nine pairs of sets for bracket placement by nine clinicians usingHBPG and BG. Teeth were then sectioned from the stone models and placed inside acrylic molds; photographs were takenand imported to a computer. In two groups, the position of each bonded bracket was compared in three aspects of vertical, mesiodistal and angular with the ideal position of every bracket. Finally, bracket positioning errors were measured. RESULTS: Mann-Whitney U test demonstrated significant differences in the means ofvertical error between the HBPG group and BG groups (P<0.001), while there were no significant differences between mesiodistal and angular errors. Facto-rial ANOVA revealed that gauge and tooth type, and the position of tooth on the right and left side of the mouth play a ma-jor role in the rate of vertical error. CONCLUSION: Vertical accuracy of bracket positioning by the use of HBPG is more than that by BG. However, there is no difference between two gauges in relation to the mesiodistal and angular errors. |
format | Online Article Text |
id | pubmed-3442432 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2011 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-34424322012-09-18 Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge Mohammadi, Amir Moslemzadeh, Seyed Hossein J Dent Res Dent Clin Dent Prospect Original Article BACKGROUND AND AIMS: Diverse gauges have been used to measure and determine bracket height for correct bracket positioning. The aim of the present study was to determine and compare bracket positioning accuracy by using height bracket positioning gauge (HBPG) and Boone gauge (BG). MATERIALS AND METHODS: Nineteen sets of stone models were prepared from one patient. One set was employed to de-termine the ideal position of brackets, and the remaining nine pairs of sets for bracket placement by nine clinicians usingHBPG and BG. Teeth were then sectioned from the stone models and placed inside acrylic molds; photographs were takenand imported to a computer. In two groups, the position of each bonded bracket was compared in three aspects of vertical, mesiodistal and angular with the ideal position of every bracket. Finally, bracket positioning errors were measured. RESULTS: Mann-Whitney U test demonstrated significant differences in the means ofvertical error between the HBPG group and BG groups (P<0.001), while there were no significant differences between mesiodistal and angular errors. Facto-rial ANOVA revealed that gauge and tooth type, and the position of tooth on the right and left side of the mouth play a ma-jor role in the rate of vertical error. CONCLUSION: Vertical accuracy of bracket positioning by the use of HBPG is more than that by BG. However, there is no difference between two gauges in relation to the mesiodistal and angular errors. Tabriz University of Medical Sciences 2011 2011-12-19 /pmc/articles/PMC3442432/ /pubmed/22991618 http://dx.doi.org/10.5681/joddd.2011.026 Text en © 2011 The Authors; Tabriz University of Medical Sciences http://creativecommons.org/licenses/by/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mohammadi, Amir Moslemzadeh, Seyed Hossein Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge |
title | Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge |
title_full | Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge |
title_fullStr | Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge |
title_full_unstemmed | Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge |
title_short | Comparison of the Accuracy of Bracket Placement with Height Bracket Positioning Gauge and Boone Gauge |
title_sort | comparison of the accuracy of bracket placement with height bracket positioning gauge and boone gauge |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3442432/ https://www.ncbi.nlm.nih.gov/pubmed/22991618 http://dx.doi.org/10.5681/joddd.2011.026 |
work_keys_str_mv | AT mohammadiamir comparisonoftheaccuracyofbracketplacementwithheightbracketpositioninggaugeandboonegauge AT moslemzadehseyedhossein comparisonoftheaccuracyofbracketplacementwithheightbracketpositioninggaugeandboonegauge |