Cargando…

Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations

BACKGROUND: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the p...

Descripción completa

Detalles Bibliográficos
Autores principales: Artner, Juraj, Cakir, Balkan, Reichel, Heiko, Lattig, Friederike
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3442745/
https://www.ncbi.nlm.nih.gov/pubmed/23028237
http://dx.doi.org/10.2147/JPR.S34429
_version_ 1782243477372796928
author Artner, Juraj
Cakir, Balkan
Reichel, Heiko
Lattig, Friederike
author_facet Artner, Juraj
Cakir, Balkan
Reichel, Heiko
Lattig, Friederike
author_sort Artner, Juraj
collection PubMed
description BACKGROUND: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique. OBJECTIVE: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections. STUDY DESIGN: Comparative study with technical considerations. METHODS: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided. RESULTS: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy- guidance levels. CONCLUSION: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible.
format Online
Article
Text
id pubmed-3442745
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-34427452012-10-01 Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations Artner, Juraj Cakir, Balkan Reichel, Heiko Lattig, Friederike J Pain Res Original Research BACKGROUND: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique. OBJECTIVE: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections. STUDY DESIGN: Comparative study with technical considerations. METHODS: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided. RESULTS: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy- guidance levels. CONCLUSION: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible. Dove Medical Press 2012-08-13 /pmc/articles/PMC3442745/ /pubmed/23028237 http://dx.doi.org/10.2147/JPR.S34429 Text en © 2012 Artner et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
spellingShingle Original Research
Artner, Juraj
Cakir, Balkan
Reichel, Heiko
Lattig, Friederike
Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_full Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_fullStr Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_full_unstemmed Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_short Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
title_sort radiation dose reduction in ct-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3442745/
https://www.ncbi.nlm.nih.gov/pubmed/23028237
http://dx.doi.org/10.2147/JPR.S34429
work_keys_str_mv AT artnerjuraj radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
AT cakirbalkan radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
AT reichelheiko radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations
AT lattigfriederike radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations