Cargando…
Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations
BACKGROUND: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the p...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3442745/ https://www.ncbi.nlm.nih.gov/pubmed/23028237 http://dx.doi.org/10.2147/JPR.S34429 |
_version_ | 1782243477372796928 |
---|---|
author | Artner, Juraj Cakir, Balkan Reichel, Heiko Lattig, Friederike |
author_facet | Artner, Juraj Cakir, Balkan Reichel, Heiko Lattig, Friederike |
author_sort | Artner, Juraj |
collection | PubMed |
description | BACKGROUND: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique. OBJECTIVE: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections. STUDY DESIGN: Comparative study with technical considerations. METHODS: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided. RESULTS: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy- guidance levels. CONCLUSION: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible. |
format | Online Article Text |
id | pubmed-3442745 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-34427452012-10-01 Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations Artner, Juraj Cakir, Balkan Reichel, Heiko Lattig, Friederike J Pain Res Original Research BACKGROUND: The sacroiliac (SI) joint is frequently the primary source of low back pain. Over the past decades, a number of different SI injection techniques have been used in its diagnosis and therapy. Despite the concerns regarding exposure to radiation, image-guided injection techniques are the preferred method to achieve safe and precise intra-articular needle placement. The following study presents a comparison of radiation doses, calculated for fluoroscopy and CT-guided SI joint injections in standard and low-dose protocol and presents the technical possibility of CT-guidance with maximum radiation dose reduction to levels of fluoroscopic-guidance for a precise intra-articular injection technique. OBJECTIVE: To evaluate the possibility of dose reduction in CT-guided sacroiliac joint injections to pulsed-fluoroscopy-guidance levels and to compare the doses of pulsed-fluoroscopy-, CT-guidance, and low-dose CT-guidance for intra-articular SI joint injections. STUDY DESIGN: Comparative study with technical considerations. METHODS: A total of 30 CT-guided intra-articular SI joint injections were performed in January 2012 in a developed low-dose mode and the radiation doses were calculated. They were compared to 30 pulsed-fluoroscopy-guided SI joint injections, which were performed in the month before, and to five injections, performed in standard CT-guided biopsy mode for spinal interventions. The statistical significance was calculated with the SPSS software using the Mann–Whitney U-Test. Technical details and anatomical considerations were provided. RESULTS: A significant dose reduction of average 94.01% was achieved using the low-dose protocol for CT-guided SI joint injections. The radiation dose could be approximated to pulsed-fluoroscopy- guidance levels. CONCLUSION: Radiation dose of CT-guided SI joint injections can be decreased to levels of pulsed fluoroscopy with a precise intra-articular needle placement using the low-dose protocol. The technique is simple to perform, fast, and reproducible. Dove Medical Press 2012-08-13 /pmc/articles/PMC3442745/ /pubmed/23028237 http://dx.doi.org/10.2147/JPR.S34429 Text en © 2012 Artner et al, publisher and licensee Dove Medical Press Ltd This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited. |
spellingShingle | Original Research Artner, Juraj Cakir, Balkan Reichel, Heiko Lattig, Friederike Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
title | Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
title_full | Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
title_fullStr | Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
title_full_unstemmed | Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
title_short | Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
title_sort | radiation dose reduction in ct-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3442745/ https://www.ncbi.nlm.nih.gov/pubmed/23028237 http://dx.doi.org/10.2147/JPR.S34429 |
work_keys_str_mv | AT artnerjuraj radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations AT cakirbalkan radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations AT reichelheiko radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations AT lattigfriederike radiationdosereductioninctguidedsacroiliacjointinjectionstolevelsofpulsedfluoroscopyacomparativestudywithtechnicalconsiderations |