Cargando…

Real-time assessment of cigarette smoke particle deposition in vitro

BACKGROUND: Recently there has been a rapid increase in approaches to assess the effects of cigarette smoke in vitro. Despite a range of gravimetric and chemical methods, there is a requirement to identify simpler and more reliable methods to quantify in vitro whole smoke dose, to support extrapolat...

Descripción completa

Detalles Bibliográficos
Autores principales: Adamson, Jason, Hughes, Sophie, Azzopardi, David, McAughey, John, Gaça, Marianna D
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3443673/
https://www.ncbi.nlm.nih.gov/pubmed/22958446
http://dx.doi.org/10.1186/1752-153X-6-98
_version_ 1782243593354739712
author Adamson, Jason
Hughes, Sophie
Azzopardi, David
McAughey, John
Gaça, Marianna D
author_facet Adamson, Jason
Hughes, Sophie
Azzopardi, David
McAughey, John
Gaça, Marianna D
author_sort Adamson, Jason
collection PubMed
description BACKGROUND: Recently there has been a rapid increase in approaches to assess the effects of cigarette smoke in vitro. Despite a range of gravimetric and chemical methods, there is a requirement to identify simpler and more reliable methods to quantify in vitro whole smoke dose, to support extrapolation and comparisons to human/in vivo dose. We have previously characterised an in vitro exposure system using a Borgwaldt RM20S smoking machine and a chamber exposing cellular cultures to whole smoke at the air-liquid interface. In this study we demonstrate the utility of a quartz crystal microbalance (QCM), using this exposure system, to assess real-time cigarette smoke particulate deposition during a 30 minute smoke exposure. Smoke was generated at various dilutions (1:5–1:400, smoke:air) using two cigarette products, 3R4F Kentucky reference and 1 mg commercially available cigarettes. The QCM, integrated into the chamber, assessed particulate deposition and data generated were compared to traditional chemical spectrofluorometric analysis. RESULTS: The QCM chamber was able to detect mass differences between the different products within the nanogram range. 3R4F reference cigarette smoke deposition ranged from 25.75 ±2.30 μg/cm(2) (1:5) to 0.22 ±0.03 μg/cm(2) (1:400). 1 mg cigarette smoke deposition was less and ranged from 1.42 ±0.26 μg/cm(2) (1:5), to 0.13 ±0.02 μg/cm(2) (1:100). Spectrofluorometric analysis demonstrated statistically significant correlation of particulate deposition with the QCM (p < 0.05), and regression R(2) value were 97.4 %. The fitted equation for the linear model which describes the relationship is: QCM = −0.6796 + 0.9744 chemical spectrofluorescence. CONCLUSIONS: We suggest the QCM is a reliable, effective and simple tool that can be used to quantify smoke particulate deposition in real-time, in vitro and can be used to quantify other aerosols delivered to our chamber for assessment.
format Online
Article
Text
id pubmed-3443673
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34436732012-09-17 Real-time assessment of cigarette smoke particle deposition in vitro Adamson, Jason Hughes, Sophie Azzopardi, David McAughey, John Gaça, Marianna D Chem Cent J Research Article BACKGROUND: Recently there has been a rapid increase in approaches to assess the effects of cigarette smoke in vitro. Despite a range of gravimetric and chemical methods, there is a requirement to identify simpler and more reliable methods to quantify in vitro whole smoke dose, to support extrapolation and comparisons to human/in vivo dose. We have previously characterised an in vitro exposure system using a Borgwaldt RM20S smoking machine and a chamber exposing cellular cultures to whole smoke at the air-liquid interface. In this study we demonstrate the utility of a quartz crystal microbalance (QCM), using this exposure system, to assess real-time cigarette smoke particulate deposition during a 30 minute smoke exposure. Smoke was generated at various dilutions (1:5–1:400, smoke:air) using two cigarette products, 3R4F Kentucky reference and 1 mg commercially available cigarettes. The QCM, integrated into the chamber, assessed particulate deposition and data generated were compared to traditional chemical spectrofluorometric analysis. RESULTS: The QCM chamber was able to detect mass differences between the different products within the nanogram range. 3R4F reference cigarette smoke deposition ranged from 25.75 ±2.30 μg/cm(2) (1:5) to 0.22 ±0.03 μg/cm(2) (1:400). 1 mg cigarette smoke deposition was less and ranged from 1.42 ±0.26 μg/cm(2) (1:5), to 0.13 ±0.02 μg/cm(2) (1:100). Spectrofluorometric analysis demonstrated statistically significant correlation of particulate deposition with the QCM (p < 0.05), and regression R(2) value were 97.4 %. The fitted equation for the linear model which describes the relationship is: QCM = −0.6796 + 0.9744 chemical spectrofluorescence. CONCLUSIONS: We suggest the QCM is a reliable, effective and simple tool that can be used to quantify smoke particulate deposition in real-time, in vitro and can be used to quantify other aerosols delivered to our chamber for assessment. BioMed Central 2012-09-10 /pmc/articles/PMC3443673/ /pubmed/22958446 http://dx.doi.org/10.1186/1752-153X-6-98 Text en Copyright ©2012 Adamson et al.; licensee Chemistry Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Adamson, Jason
Hughes, Sophie
Azzopardi, David
McAughey, John
Gaça, Marianna D
Real-time assessment of cigarette smoke particle deposition in vitro
title Real-time assessment of cigarette smoke particle deposition in vitro
title_full Real-time assessment of cigarette smoke particle deposition in vitro
title_fullStr Real-time assessment of cigarette smoke particle deposition in vitro
title_full_unstemmed Real-time assessment of cigarette smoke particle deposition in vitro
title_short Real-time assessment of cigarette smoke particle deposition in vitro
title_sort real-time assessment of cigarette smoke particle deposition in vitro
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3443673/
https://www.ncbi.nlm.nih.gov/pubmed/22958446
http://dx.doi.org/10.1186/1752-153X-6-98
work_keys_str_mv AT adamsonjason realtimeassessmentofcigarettesmokeparticledepositioninvitro
AT hughessophie realtimeassessmentofcigarettesmokeparticledepositioninvitro
AT azzopardidavid realtimeassessmentofcigarettesmokeparticledepositioninvitro
AT mcaugheyjohn realtimeassessmentofcigarettesmokeparticledepositioninvitro
AT gacamariannad realtimeassessmentofcigarettesmokeparticledepositioninvitro