Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound

BACKGROUND: HIFU can achieve PVI, but severe esophageal complications have happened. We analyzed relative position of HIFU balloon catheter (BC) to esophageal temperature (ET) probe and correlated it to ET changes. METHODS AND RESULTS: Before each ablation relative position of HIFU BC to ET probe wa...

Descripción completa

Detalles Bibliográficos
Autores principales: Neven, Kars, Metzner, Andreas, Schmidt, Boris, Ouyang, Feifan, Kuck, Karl-Heinz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Heart Rhythm Society 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3443877/
https://www.ncbi.nlm.nih.gov/pubmed/23071381
_version_ 1782243606889758720
author Neven, Kars
Metzner, Andreas
Schmidt, Boris
Ouyang, Feifan
Kuck, Karl-Heinz
author_facet Neven, Kars
Metzner, Andreas
Schmidt, Boris
Ouyang, Feifan
Kuck, Karl-Heinz
author_sort Neven, Kars
collection PubMed
description BACKGROUND: HIFU can achieve PVI, but severe esophageal complications have happened. We analyzed relative position of HIFU balloon catheter (BC) to esophageal temperature (ET) probe and correlated it to ET changes. METHODS AND RESULTS: Before each ablation relative position of HIFU BC to ET probe was recorded in RAO 30º and LAO 40º. We compared ablations where ET at end of ablation was <38.5ºC or ≥38.5ºC and <40.0ºC or ≥40.0ºC. A total of 600 images from 311 ablations in 28 patients (18 male, age 63±7 years), were analyzed. ET ≥38.5ºC was reached when distance from BC to ET probe was: <20mm in LAO for RSPV and <29mm in LAO for RIPV. For RIPV ET ≥38.5ºC was reached when angle between BC and ET probe was significantly smaller in LAO and RAO. ET ≥40.0ºC was reached when distance of BC to ET probe was: <20mm in LAO for RIPV, <14mm in RAO for RIPV, <18mm in RAO for LIPV. ET increased to ≥40.0ºC when distance from BC to ET probe was significantly longer in LAO for LIPV. For RIPV ET ≥40.0ºC was reached when angle between BC and ET probe was significantly smaller in LAO. CONCLUSION: There is a relationship between distance/angle of HIFU BC to ET probe and ET: shorter distances and smaller angles can cause higher ET.
format Online
Article
Text
id pubmed-3443877
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Indian Heart Rhythm Society
record_format MEDLINE/PubMed
spelling pubmed-34438772012-10-15 Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound Neven, Kars Metzner, Andreas Schmidt, Boris Ouyang, Feifan Kuck, Karl-Heinz Indian Pacing Electrophysiol J Original Article BACKGROUND: HIFU can achieve PVI, but severe esophageal complications have happened. We analyzed relative position of HIFU balloon catheter (BC) to esophageal temperature (ET) probe and correlated it to ET changes. METHODS AND RESULTS: Before each ablation relative position of HIFU BC to ET probe was recorded in RAO 30º and LAO 40º. We compared ablations where ET at end of ablation was <38.5ºC or ≥38.5ºC and <40.0ºC or ≥40.0ºC. A total of 600 images from 311 ablations in 28 patients (18 male, age 63±7 years), were analyzed. ET ≥38.5ºC was reached when distance from BC to ET probe was: <20mm in LAO for RSPV and <29mm in LAO for RIPV. For RIPV ET ≥38.5ºC was reached when angle between BC and ET probe was significantly smaller in LAO and RAO. ET ≥40.0ºC was reached when distance of BC to ET probe was: <20mm in LAO for RIPV, <14mm in RAO for RIPV, <18mm in RAO for LIPV. ET increased to ≥40.0ºC when distance from BC to ET probe was significantly longer in LAO for LIPV. For RIPV ET ≥40.0ºC was reached when angle between BC and ET probe was significantly smaller in LAO. CONCLUSION: There is a relationship between distance/angle of HIFU BC to ET probe and ET: shorter distances and smaller angles can cause higher ET. Indian Heart Rhythm Society 2012-09-01 /pmc/articles/PMC3443877/ /pubmed/23071381 Text en Copyright: © 2012 Neven et al. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Neven, Kars
Metzner, Andreas
Schmidt, Boris
Ouyang, Feifan
Kuck, Karl-Heinz
Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound
title Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound
title_full Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound
title_fullStr Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound
title_full_unstemmed Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound
title_short Balloon Catheter Position and its Relationship with Esophageal Temperature during Pulmonary Vein Isolation using High-Intensity Focused Ultrasound
title_sort balloon catheter position and its relationship with esophageal temperature during pulmonary vein isolation using high-intensity focused ultrasound
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3443877/
https://www.ncbi.nlm.nih.gov/pubmed/23071381
work_keys_str_mv AT nevenkars ballooncatheterpositionanditsrelationshipwithesophagealtemperatureduringpulmonaryveinisolationusinghighintensityfocusedultrasound
AT metznerandreas ballooncatheterpositionanditsrelationshipwithesophagealtemperatureduringpulmonaryveinisolationusinghighintensityfocusedultrasound
AT schmidtboris ballooncatheterpositionanditsrelationshipwithesophagealtemperatureduringpulmonaryveinisolationusinghighintensityfocusedultrasound
AT ouyangfeifan ballooncatheterpositionanditsrelationshipwithesophagealtemperatureduringpulmonaryveinisolationusinghighintensityfocusedultrasound
AT kuckkarlheinz ballooncatheterpositionanditsrelationshipwithesophagealtemperatureduringpulmonaryveinisolationusinghighintensityfocusedultrasound