Cargando…

An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation

Utilizing a simple fluidic structure, we demonstrate the improved performance of oxidase-based enzymatic biosensors. Electrolysis of water is utilized to generate bubbles to manipulate the oxygen microenvironment close to the biosensor in a fluidic channel. For the proper enzyme reactions to occur,...

Descripción completa

Detalles Bibliográficos
Autores principales: Radhakrishnan, Nitin, Park, Jongwon, Kim, Chang-Soo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Molecular Diversity Preservation International (MDPI) 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444085/
https://www.ncbi.nlm.nih.gov/pubmed/23012527
http://dx.doi.org/10.3390/s120708955
_version_ 1782243630365278208
author Radhakrishnan, Nitin
Park, Jongwon
Kim, Chang-Soo
author_facet Radhakrishnan, Nitin
Park, Jongwon
Kim, Chang-Soo
author_sort Radhakrishnan, Nitin
collection PubMed
description Utilizing a simple fluidic structure, we demonstrate the improved performance of oxidase-based enzymatic biosensors. Electrolysis of water is utilized to generate bubbles to manipulate the oxygen microenvironment close to the biosensor in a fluidic channel. For the proper enzyme reactions to occur, a simple mechanical procedure of manipulating bubbles was developed to maximize the oxygen level while minimizing the pH change after electrolysis. The sensors show improved sensitivities based on the oxygen dependency of enzyme reaction. In addition, this oxygen-rich operation minimizes the ratio of electrochemical interference signal by ascorbic acid during sensor operation (i.e., amperometric detection of hydrogen peroxide). Although creatinine sensors have been used as the model system in this study, this method is applicable to many other biosensors that can use oxidase enzymes (e.g., glucose, alcohol, phenol, etc.) to implement a viable component for in-line fluidic sensor systems.
format Online
Article
Text
id pubmed-3444085
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher Molecular Diversity Preservation International (MDPI)
record_format MEDLINE/PubMed
spelling pubmed-34440852012-09-25 An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation Radhakrishnan, Nitin Park, Jongwon Kim, Chang-Soo Sensors (Basel) Article Utilizing a simple fluidic structure, we demonstrate the improved performance of oxidase-based enzymatic biosensors. Electrolysis of water is utilized to generate bubbles to manipulate the oxygen microenvironment close to the biosensor in a fluidic channel. For the proper enzyme reactions to occur, a simple mechanical procedure of manipulating bubbles was developed to maximize the oxygen level while minimizing the pH change after electrolysis. The sensors show improved sensitivities based on the oxygen dependency of enzyme reaction. In addition, this oxygen-rich operation minimizes the ratio of electrochemical interference signal by ascorbic acid during sensor operation (i.e., amperometric detection of hydrogen peroxide). Although creatinine sensors have been used as the model system in this study, this method is applicable to many other biosensors that can use oxidase enzymes (e.g., glucose, alcohol, phenol, etc.) to implement a viable component for in-line fluidic sensor systems. Molecular Diversity Preservation International (MDPI) 2012-06-29 /pmc/articles/PMC3444085/ /pubmed/23012527 http://dx.doi.org/10.3390/s120708955 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).
spellingShingle Article
Radhakrishnan, Nitin
Park, Jongwon
Kim, Chang-Soo
An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation
title An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation
title_full An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation
title_fullStr An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation
title_full_unstemmed An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation
title_short An Oxidase-Based Electrochemical Fluidic Sensor with High-Sensitivity and Low-Interference by On-Chip Oxygen Manipulation
title_sort oxidase-based electrochemical fluidic sensor with high-sensitivity and low-interference by on-chip oxygen manipulation
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444085/
https://www.ncbi.nlm.nih.gov/pubmed/23012527
http://dx.doi.org/10.3390/s120708955
work_keys_str_mv AT radhakrishnannitin anoxidasebasedelectrochemicalfluidicsensorwithhighsensitivityandlowinterferencebyonchipoxygenmanipulation
AT parkjongwon anoxidasebasedelectrochemicalfluidicsensorwithhighsensitivityandlowinterferencebyonchipoxygenmanipulation
AT kimchangsoo anoxidasebasedelectrochemicalfluidicsensorwithhighsensitivityandlowinterferencebyonchipoxygenmanipulation
AT radhakrishnannitin oxidasebasedelectrochemicalfluidicsensorwithhighsensitivityandlowinterferencebyonchipoxygenmanipulation
AT parkjongwon oxidasebasedelectrochemicalfluidicsensorwithhighsensitivityandlowinterferencebyonchipoxygenmanipulation
AT kimchangsoo oxidasebasedelectrochemicalfluidicsensorwithhighsensitivityandlowinterferencebyonchipoxygenmanipulation