Cargando…
A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection
A portable and power-free microfluidic device was designed for rapid and sensitive detection of lead (Pb(2+)). 11-mercaptoundecanoic acid (MUA)-functionalized gold nanoparticles (MUA-AuNPs) aggregated in the presence of Pb(2+) for the chelation mechanism. When we performed this analysis on a polydim...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Molecular Diversity Preservation International (MDPI)
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444111/ https://www.ncbi.nlm.nih.gov/pubmed/23012553 http://dx.doi.org/10.3390/s120709467 |
_version_ | 1782243636609548288 |
---|---|
author | Fan, Chunhui He, Shijiang Liu, Gang Wang, Lianhui Song, Shiping |
author_facet | Fan, Chunhui He, Shijiang Liu, Gang Wang, Lianhui Song, Shiping |
author_sort | Fan, Chunhui |
collection | PubMed |
description | A portable and power-free microfluidic device was designed for rapid and sensitive detection of lead (Pb(2+)). 11-mercaptoundecanoic acid (MUA)-functionalized gold nanoparticles (MUA-AuNPs) aggregated in the presence of Pb(2+) for the chelation mechanism. When we performed this analysis on a polydimethylsiloxane (PDMS) microfluidic chip, the aggregations deposited onto the surface of chip and formed dark lines along the laminar flows in the zigzag microchannels. This visual result can be observed by the naked eye through a microscope or just a drop of water as a magnifier. Ten μM Pb(2+) was successfully detected. |
format | Online Article Text |
id | pubmed-3444111 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Molecular Diversity Preservation International (MDPI) |
record_format | MEDLINE/PubMed |
spelling | pubmed-34441112012-09-25 A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection Fan, Chunhui He, Shijiang Liu, Gang Wang, Lianhui Song, Shiping Sensors (Basel) Article A portable and power-free microfluidic device was designed for rapid and sensitive detection of lead (Pb(2+)). 11-mercaptoundecanoic acid (MUA)-functionalized gold nanoparticles (MUA-AuNPs) aggregated in the presence of Pb(2+) for the chelation mechanism. When we performed this analysis on a polydimethylsiloxane (PDMS) microfluidic chip, the aggregations deposited onto the surface of chip and formed dark lines along the laminar flows in the zigzag microchannels. This visual result can be observed by the naked eye through a microscope or just a drop of water as a magnifier. Ten μM Pb(2+) was successfully detected. Molecular Diversity Preservation International (MDPI) 2012-07-10 /pmc/articles/PMC3444111/ /pubmed/23012553 http://dx.doi.org/10.3390/s120709467 Text en © 2012 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). |
spellingShingle | Article Fan, Chunhui He, Shijiang Liu, Gang Wang, Lianhui Song, Shiping A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection |
title | A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection |
title_full | A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection |
title_fullStr | A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection |
title_full_unstemmed | A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection |
title_short | A Portable and Power-Free Microfluidic Device for Rapid and Sensitive Lead (Pb(2+)) Detection |
title_sort | portable and power-free microfluidic device for rapid and sensitive lead (pb(2+)) detection |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444111/ https://www.ncbi.nlm.nih.gov/pubmed/23012553 http://dx.doi.org/10.3390/s120709467 |
work_keys_str_mv | AT fanchunhui aportableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT heshijiang aportableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT liugang aportableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT wanglianhui aportableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT songshiping aportableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT fanchunhui portableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT heshijiang portableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT liugang portableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT wanglianhui portableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection AT songshiping portableandpowerfreemicrofluidicdeviceforrapidandsensitiveleadpb2detection |