Cargando…
A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer
BACKGROUND: To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS: Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT a...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444363/ https://www.ncbi.nlm.nih.gov/pubmed/22824133 http://dx.doi.org/10.1186/1748-717X-7-111 |
_version_ | 1782243668978040832 |
---|---|
author | Foroudi, Farshad Wilson, Lesley Bressel, Mathias Haworth, Annette Hornby, Colin Pham, Daniel Cramb, Jim Gill, Suki Tai, Keen Hun Kron, Tomas |
author_facet | Foroudi, Farshad Wilson, Lesley Bressel, Mathias Haworth, Annette Hornby, Colin Pham, Daniel Cramb, Jim Gill, Suki Tai, Keen Hun Kron, Tomas |
author_sort | Foroudi, Farshad |
collection | PubMed |
description | BACKGROUND: To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS: Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. RESULTS: Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. CONCLUSIONS: VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours. |
format | Online Article Text |
id | pubmed-3444363 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-34443632012-09-20 A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer Foroudi, Farshad Wilson, Lesley Bressel, Mathias Haworth, Annette Hornby, Colin Pham, Daniel Cramb, Jim Gill, Suki Tai, Keen Hun Kron, Tomas Radiat Oncol Research BACKGROUND: To compare 3 Dimensional Conformal radiotherapy (3D-CRT) with Intensity Modulated Radiotherapy (IMRT) with Volumetric-Modulated Arc Therapy (VMAT) for bladder cancer. METHODS: Radiotherapy plans for 15 patients with T2-T4N0M0 bladder cancer were prospectively developed for 3-DCRT, IMRT and VMAT using Varian Eclipse planning system. The same radiation therapist carried out all planning and the same clinical dosimetric constraints were used. 10 of the patients with well localised tumours had a simultaneous infield boost (SIB) of the primary tumour planned for both IMRT and VMAT. Tumour control probabilities and normal tissue complication probabilities were calculated. RESULTS: Mean planning time for 3D-CRT, IMRT and VMAT was 30.0, 49.3, and 141.0 minutes respectively. The mean PTV conformity (CI) index for 3D-CRT was 1.32, for IMRT 1.05, and for VMAT 1.05. The PTV Homogeneity (HI) index was 0.080 for 3D-CRT, 0.073 for IMRT and 0.086 for VMAT. Tumour control and normal tissue complication probabilities were similar for 3D-CRT, IMRT and VMAT. The mean monitor units were 267 (range 250–293) for 3D-CRT; 824 (range 641–1083) for IMRT; and 403 (range 333–489) for VMAT (P < 0.05). Average treatment delivery time were 2:25min (range 2:01–3:09) for 3D-CRT; 4:39 (range 3:41–6:40) for IMRT; and 1:14 (range 1:13–1:14) for VMAT. In selected patients, the SIB did not result in a higher dose to small bowel or rectum. CONCLUSIONS: VMAT is associated with similar dosimetric advantages as IMRT over 3D-CRT for muscle invasive bladder cancer. VMAT is associated with faster delivery times and less number of mean monitor units than IMRT. SIB is feasible in selected patients with localized tumours. BioMed Central 2012-07-23 /pmc/articles/PMC3444363/ /pubmed/22824133 http://dx.doi.org/10.1186/1748-717X-7-111 Text en Copyright ©2012 Foroudi et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Foroudi, Farshad Wilson, Lesley Bressel, Mathias Haworth, Annette Hornby, Colin Pham, Daniel Cramb, Jim Gill, Suki Tai, Keen Hun Kron, Tomas A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
title | A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
title_full | A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
title_fullStr | A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
title_full_unstemmed | A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
title_short | A dosimetric comparison of 3D conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
title_sort | dosimetric comparison of 3d conformal vs intensity modulated vs volumetric arc radiation therapy for muscle invasive bladder cancer |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444363/ https://www.ncbi.nlm.nih.gov/pubmed/22824133 http://dx.doi.org/10.1186/1748-717X-7-111 |
work_keys_str_mv | AT foroudifarshad adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT wilsonlesley adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT bresselmathias adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT haworthannette adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT hornbycolin adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT phamdaniel adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT crambjim adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT gillsuki adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT taikeenhun adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT krontomas adosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT foroudifarshad dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT wilsonlesley dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT bresselmathias dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT haworthannette dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT hornbycolin dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT phamdaniel dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT crambjim dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT gillsuki dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT taikeenhun dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer AT krontomas dosimetriccomparisonof3dconformalvsintensitymodulatedvsvolumetricarcradiationtherapyformuscleinvasivebladdercancer |