Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test
BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW) testing, participants’ ability to interpret sample res...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444491/ https://www.ncbi.nlm.nih.gov/pubmed/23028822 http://dx.doi.org/10.1371/journal.pone.0045168 |
_version_ | 1782243699596460032 |
---|---|
author | Ng, Oon Tek Chow, Angela L. Lee, Vernon J. Chen, Mark I. C. Win, Mar Kyaw Tan, Hiok Hee Chua, Arlene Leo, Yee Sin |
author_facet | Ng, Oon Tek Chow, Angela L. Lee, Vernon J. Chen, Mark I. C. Win, Mar Kyaw Tan, Hiok Hee Chua, Arlene Leo, Yee Sin |
author_sort | Ng, Oon Tek |
collection | PubMed |
description | BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW) testing, participants’ ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience) performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid) to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%), negative in 5 (2.6%), and invalid in 1 (0.5%). Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%), positive in 1 (0.1%), and invalid in 2 (0.3%). Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7%) and specificity of 99.9% (95% CI: 99.6% to 100%). When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as invalid was a major reason for incorrect result interpretation. Survey responses were supportive of making self-testing available. |
format | Online Article Text |
id | pubmed-3444491 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-34444912012-10-01 Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test Ng, Oon Tek Chow, Angela L. Lee, Vernon J. Chen, Mark I. C. Win, Mar Kyaw Tan, Hiok Hee Chua, Arlene Leo, Yee Sin PLoS One Research Article BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW) testing, participants’ ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience) performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid) to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%), negative in 5 (2.6%), and invalid in 1 (0.5%). Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%), positive in 1 (0.1%), and invalid in 2 (0.3%). Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7%) and specificity of 99.9% (95% CI: 99.6% to 100%). When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as invalid was a major reason for incorrect result interpretation. Survey responses were supportive of making self-testing available. Public Library of Science 2012-09-17 /pmc/articles/PMC3444491/ /pubmed/23028822 http://dx.doi.org/10.1371/journal.pone.0045168 Text en © 2012 Ng et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Ng, Oon Tek Chow, Angela L. Lee, Vernon J. Chen, Mark I. C. Win, Mar Kyaw Tan, Hiok Hee Chua, Arlene Leo, Yee Sin Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test |
title | Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test |
title_full | Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test |
title_fullStr | Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test |
title_full_unstemmed | Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test |
title_short | Accuracy and User-Acceptability of HIV Self-Testing Using an Oral Fluid-Based HIV Rapid Test |
title_sort | accuracy and user-acceptability of hiv self-testing using an oral fluid-based hiv rapid test |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444491/ https://www.ncbi.nlm.nih.gov/pubmed/23028822 http://dx.doi.org/10.1371/journal.pone.0045168 |
work_keys_str_mv | AT ngoontek accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT chowangelal accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT leevernonj accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT chenmarkic accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT winmarkyaw accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT tanhiokhee accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT chuaarlene accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest AT leoyeesin accuracyanduseracceptabilityofhivselftestingusinganoralfluidbasedhivrapidtest |