Cargando…

Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report

INTRODUCTION: Local aneurysms after surgical repair of coarctation of the aorta occur mainly in patients surgically treated by Dacron patch plasty during adulthood. The management of these patients is always problematic, with frequent complications and increased mortality rates. Percutaneous stent-g...

Descripción completa

Detalles Bibliográficos
Autores principales: Tilea, Ioan, Hadadi, Laszlo, Serban, Razvan C, Tilea, Brindusa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2012
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444921/
https://www.ncbi.nlm.nih.gov/pubmed/22935451
http://dx.doi.org/10.1186/1752-1947-6-255
_version_ 1782243739969781760
author Tilea, Ioan
Hadadi, Laszlo
Serban, Razvan C
Tilea, Brindusa
author_facet Tilea, Ioan
Hadadi, Laszlo
Serban, Razvan C
Tilea, Brindusa
author_sort Tilea, Ioan
collection PubMed
description INTRODUCTION: Local aneurysms after surgical repair of coarctation of the aorta occur mainly in patients surgically treated by Dacron patch plasty during adulthood. The management of these patients is always problematic, with frequent complications and increased mortality rates. Percutaneous stent-graft implantation avoids the need for surgical reintervention. CASE PRESENTATION: We report a case involving the hybrid treatment by stent-graft implantation and transposition of the left subclavian artery to the left common carotid artery of an aneurysmal dilatation of the thoracic aorta that occurred in a 64-year-old Caucasian man, operated on almost 40 years earlier with a Dacron patch plasty for aortic coarctation. Our patient presented to our facility for evaluation with back pain and shortness of breath after minimal physical effort. A physical examination revealed stony dullness to percussion of the left posterior thorax, with no other abnormalities. The results of chest radiography, followed by contrast-enhanced computed tomography and aortography, led to a diagnosis of giant aortic thoracic aneurysm. Successful treatment of the aneurysm was achieved by percutaneous stent-graft implantation combined with transposition of the left subclavian artery to the left common carotid artery. His post-procedural recovery was uneventful. Three months after the procedure, computed tomography showed complete thrombosis of the excluded aneurysm, without any clinical signs of left lower limb ischemia or new onset neurological abnormalities. CONCLUSIONS: Our patient’s case illustrates the clinical outcomes of surgical interventions for aortic coarctation. However, the very late appearance of a local aneurysm is rather unusual. Management of such cases is always difficult. The decision-making should be multidisciplinary. A hybrid approach was considered the best solution for our patient.
format Online
Article
Text
id pubmed-3444921
institution National Center for Biotechnology Information
language English
publishDate 2012
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-34449212012-09-19 Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report Tilea, Ioan Hadadi, Laszlo Serban, Razvan C Tilea, Brindusa J Med Case Rep Case Report INTRODUCTION: Local aneurysms after surgical repair of coarctation of the aorta occur mainly in patients surgically treated by Dacron patch plasty during adulthood. The management of these patients is always problematic, with frequent complications and increased mortality rates. Percutaneous stent-graft implantation avoids the need for surgical reintervention. CASE PRESENTATION: We report a case involving the hybrid treatment by stent-graft implantation and transposition of the left subclavian artery to the left common carotid artery of an aneurysmal dilatation of the thoracic aorta that occurred in a 64-year-old Caucasian man, operated on almost 40 years earlier with a Dacron patch plasty for aortic coarctation. Our patient presented to our facility for evaluation with back pain and shortness of breath after minimal physical effort. A physical examination revealed stony dullness to percussion of the left posterior thorax, with no other abnormalities. The results of chest radiography, followed by contrast-enhanced computed tomography and aortography, led to a diagnosis of giant aortic thoracic aneurysm. Successful treatment of the aneurysm was achieved by percutaneous stent-graft implantation combined with transposition of the left subclavian artery to the left common carotid artery. His post-procedural recovery was uneventful. Three months after the procedure, computed tomography showed complete thrombosis of the excluded aneurysm, without any clinical signs of left lower limb ischemia or new onset neurological abnormalities. CONCLUSIONS: Our patient’s case illustrates the clinical outcomes of surgical interventions for aortic coarctation. However, the very late appearance of a local aneurysm is rather unusual. Management of such cases is always difficult. The decision-making should be multidisciplinary. A hybrid approach was considered the best solution for our patient. BioMed Central 2012-08-30 /pmc/articles/PMC3444921/ /pubmed/22935451 http://dx.doi.org/10.1186/1752-1947-6-255 Text en Copyright ©2012 Tilea et al.; licensee BioMed Central Ltd. http://creativecommons.org/licenses/by/2.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Tilea, Ioan
Hadadi, Laszlo
Serban, Razvan C
Tilea, Brindusa
Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
title Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
title_full Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
title_fullStr Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
title_full_unstemmed Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
title_short Hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
title_sort hybrid repair of a very late, post-aortic coarctation surgery thoracic aneurysm: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3444921/
https://www.ncbi.nlm.nih.gov/pubmed/22935451
http://dx.doi.org/10.1186/1752-1947-6-255
work_keys_str_mv AT tileaioan hybridrepairofaverylatepostaorticcoarctationsurgerythoracicaneurysmacasereport
AT hadadilaszlo hybridrepairofaverylatepostaorticcoarctationsurgerythoracicaneurysmacasereport
AT serbanrazvanc hybridrepairofaverylatepostaorticcoarctationsurgerythoracicaneurysmacasereport
AT tileabrindusa hybridrepairofaverylatepostaorticcoarctationsurgerythoracicaneurysmacasereport