Cargando…
Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography
PURPOSE: There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Four...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2012
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3445512/ https://www.ncbi.nlm.nih.gov/pubmed/23029289 http://dx.doi.org/10.1371/journal.pone.0045876 |
_version_ | 1782243828123566080 |
---|---|
author | Werkmeister, René M. Palkovits, Stefan Told, Reinhard Gröschl, Martin Leitgeb, Rainer A. Garhöfer, Gerhard Schmetterer, Leopold |
author_facet | Werkmeister, René M. Palkovits, Stefan Told, Reinhard Gröschl, Martin Leitgeb, Rainer A. Garhöfer, Gerhard Schmetterer, Leopold |
author_sort | Werkmeister, René M. |
collection | PubMed |
description | PURPOSE: There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breathing on retinal blood flow. These data were compared to data obtained with a laser Doppler velocimeter (LDV). METHODS: 10 healthy subjects were studied on 2 study days. On one study day the effect of 100% oxygen breathing on retinal blood velocities was studied using dual-beam bidirectional Doppler FD-OCT. On the second study day the effect of 100% oxygen breathing on retinal blood velocities was assessed by laser Doppler velocimetry (LDV). Retinal vessel diameters were measured on both study days using a commercially available Dynamic Vessel Analyzer. Retinal blood flow was calculated based on retinal vessel diameters and red blood cell velocity. RESULTS: As expected, breathing of pure oxygen induced a pronounced reduction in retinal vessel diameters, retinal blood velocities and retinal blood flow on both study days (p<0.001). Blood velocity data correlated well between the two methods applied under both baseline as well as under hyperoxic conditions (r = 0.98 and r = 0.75, respectively). Data as obtained with OCT were, however, slightly higher. CONCLUSION: A good correlation was found between red blood cell velocity as measured with dual-beam bidirectional Doppler FD-OCT and red blood cell velocity assessed by the laser Doppler method. Dual-beam bidirectional Doppler FD-OCT is a promising approach for studying retinal blood velocities in vivo. |
format | Online Article Text |
id | pubmed-3445512 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2012 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-34455122012-10-01 Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography Werkmeister, René M. Palkovits, Stefan Told, Reinhard Gröschl, Martin Leitgeb, Rainer A. Garhöfer, Gerhard Schmetterer, Leopold PLoS One Research Article PURPOSE: There is a long-standing interest in the study of retinal blood flow in humans. In the recent years techniques have been established to measure retinal perfusion based on optical coherence tomography (OCT). In the present study we used a technique called dual-beam bidirectional Doppler Fourier-domain optical coherence tomography (FD-OCT) to characterize the effects of 100% oxygen breathing on retinal blood flow. These data were compared to data obtained with a laser Doppler velocimeter (LDV). METHODS: 10 healthy subjects were studied on 2 study days. On one study day the effect of 100% oxygen breathing on retinal blood velocities was studied using dual-beam bidirectional Doppler FD-OCT. On the second study day the effect of 100% oxygen breathing on retinal blood velocities was assessed by laser Doppler velocimetry (LDV). Retinal vessel diameters were measured on both study days using a commercially available Dynamic Vessel Analyzer. Retinal blood flow was calculated based on retinal vessel diameters and red blood cell velocity. RESULTS: As expected, breathing of pure oxygen induced a pronounced reduction in retinal vessel diameters, retinal blood velocities and retinal blood flow on both study days (p<0.001). Blood velocity data correlated well between the two methods applied under both baseline as well as under hyperoxic conditions (r = 0.98 and r = 0.75, respectively). Data as obtained with OCT were, however, slightly higher. CONCLUSION: A good correlation was found between red blood cell velocity as measured with dual-beam bidirectional Doppler FD-OCT and red blood cell velocity assessed by the laser Doppler method. Dual-beam bidirectional Doppler FD-OCT is a promising approach for studying retinal blood velocities in vivo. Public Library of Science 2012-09-18 /pmc/articles/PMC3445512/ /pubmed/23029289 http://dx.doi.org/10.1371/journal.pone.0045876 Text en © 2012 Werkmeister et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Werkmeister, René M. Palkovits, Stefan Told, Reinhard Gröschl, Martin Leitgeb, Rainer A. Garhöfer, Gerhard Schmetterer, Leopold Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography |
title | Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography |
title_full | Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography |
title_fullStr | Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography |
title_full_unstemmed | Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography |
title_short | Response of Retinal Blood Flow to Systemic Hyperoxia as Measured with Dual-Beam Bidirectional Doppler Fourier-Domain Optical Coherence Tomography |
title_sort | response of retinal blood flow to systemic hyperoxia as measured with dual-beam bidirectional doppler fourier-domain optical coherence tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3445512/ https://www.ncbi.nlm.nih.gov/pubmed/23029289 http://dx.doi.org/10.1371/journal.pone.0045876 |
work_keys_str_mv | AT werkmeisterrenem responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography AT palkovitsstefan responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography AT toldreinhard responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography AT groschlmartin responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography AT leitgebrainera responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography AT garhofergerhard responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography AT schmettererleopold responseofretinalbloodflowtosystemichyperoxiaasmeasuredwithdualbeambidirectionaldopplerfourierdomainopticalcoherencetomography |